Specifications

  • Model: VT-8603, VT-8613, VT-8623, VT-8633
  • SKU: 801-24, 804-24, 806-24, 812-24
  • Beam Angle: >80 degrees
  • CRI: DF
  • Life Span: 30,000 hours
  • Input Voltage: AC:200-240V, 50Hz
  • Material: PC
  • Dimension: 320x100mm
  • Warranty: 5 Year (VT-8603, VT-8613), 3 Year (VT-8623, VT-8633)

Product Usage Instructions

Installation Instructions

  1. Switch OFF the power before starting the installation.
  2. Remove the cover by holding the luminaire upside down. Press 3 clips on the sides and pull the base upwards to open and set aside.
  3. Carefully press and unlock the screw on the LED hinged tray and hold the tray at an upward 90-degree position. Hold the product upside down.
  4. Hold the product in place, mark & drill the holes into the wall and nail the alligator into the hole. Feed the supply cable into the luminaire through the cable entry hole.
  5. Switch ON the power to test the light.

Instructions for Changing Color & Power (Available on Driver)

  • CCT ON 3000K (Y)
  • CCT ON 4000K (WY)
  • CCT ON 6400K (W)

Pre-install Emergency Function Test

  • Power options: 20W, 16W, 8W

Sensor Settings

Refer to FIG 1, FIG 2, and FIG 3 for sensor settings. Disabled, only the motion sensor will work [FIG 3].

Application [Function Demo – Dimmable Control/Corridor Function]

  • When motion is detected but the daylight is sufficient, the light will remain OFF.
  • When motion is detected and the daylight is insufficient, the light will be ON.
  • After a stand-by period, the light will switch OFF.

FAQ

  • Q: How do I reach out for support or queries?
  • A: In case of any query/issue with the product, please reach out to us at [email protected] or visit V-TAC House, Kelpatrick Road, Slough, Berkshire, SL1 6BW, UK.
  • Q: What should I do if I encounter an issue with the product?
  • A: Contact the manufacturer or a qualified service agent to avoid hazards. Do not dispose of the product with other household wastes.

TECHNICAL DATA

 

MODEL

 

SKU

BEAM ANGLE  

CRI

 

DF

LIFE SPAN (HOURS) INPUT VOLTAGE  

MATERIAl

 

DIMENSION

 

WARRANTY

VT-8603 801-24 110° >80 0.9 30,000 AC:200-240V, 50Hz PC 320x100mm 5 Year
VT-8613 804-24 110° >80 0.9 30,000 AC:200-240V, 50Hz PC 320x100mm 5 Year
VT-8623 806-24 110° >80 0.9 30,000 AC:200-240V, 50Hz PC 320x100mm 3 Year
VT-8633 812-24 110° >80 0.9 30,000 AC:200-240V, 50Hz PC 320x100mm 3 Year

SPECIFICATIONS

SENSOR SPECIFICATIONS

 

MODEL

DETECTION ANGLE DETECTION DISTANCE DETECTION RANGE MAX.  

HOLD TIME

DAYLIGHT SENSOR MANUAL OVERRIDE DETECTION MOTION SPEED
 

VT-8613 VT-8633

360° If Ceiling Mounting 120° If Wall mounting  

 

3-6 M

 

 

D6Mx3M

 

5s, 30s,90s,

3min,20min,30min

 

Day, 2LUX,10LUX-

,25LUX Optional

 

Available by dial switch

 

 

0.5-3m/s

EMERGENCY SPECIFICATIONS

 

MODEL

EMERGENCY OPERATION TIME  

EMERGENCY STANDBY WATTS

BATTERY CHARGING CURRENT BATTERY DISCHARGING CURRENT  

BATTERY TYPE

 

TEST BUTTON

 

CHARGING INDICATOR

VT-8623 >3 Hours >1.2 Watts 250mA 410mA LiFePO4, 3.2V, 2Ah With Green LED

WARNING

  • Please make sure to turn off the power before starting the installation.
  • Installation must be performed by a qualified person.
  • The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similarly qualified person in order to avoid a hazard.

V-TAC-VT-8603-20W -LED-Dome-Light-FIG-1Caution, Risk of electric shock
V-TAC-VT-8603-20W -LED-Dome-Light-FIG-2This marking indicates that this product should not be disposed of with other household wastes.

INSTALLATION INSTRUCTIONS

  1. Switch OFF the power before starting the installation.V-TAC-VT-8603-20W -LED-Dome-Light-FIG-3
  2. Remove the cover by holding the luminaire upside down. Press 3 clips on the sides pull the base upwards to open it and set it aside.V-TAC-VT-8603-20W -LED-Dome-Light-FIG-4
  3. Carefully press and unlock the screw on the led hinged tray and hold the tray at an upward 90Degree position. Hold the product upside down.V-TAC-VT-8603-20W -LED-Dome-Light-FIG-5
  4. Hold the product in place, mark & drill the holes into the wall and nail the alligator into the hole. Feed the supply cable into the luminaire through the cable entry holeV-TAC-VT-8603-20W -LED-Dome-Light-FIG-6
  5. Once the base is installed, carefully put back the hinged tray by pushing it forward.
    1. Hold the tray with the base and twist the screw to lock it back.V-TAC-VT-8603-20W -LED-Dome-Light-FIG-7
  6. Carefully close the cover by aligning with the marked arrows on the base ( Locate the Side conduit) and the cover to avoid breakage while closing.
    1. Push down from all 3 sides to properly secure the 3 clips on the sides.V-TAC-VT-8603-20W -LED-Dome-Light-FIG-8
  7. Switch ON the power to test the light.V-TAC-VT-8603-20W -LED-Dome-Light-FIG-9

INSTRUCTIONS FOR CHANGING COLOR & POWER (AVAILABLE ON DRIVER)

V-TAC-VT-8603-20W -LED-Dome-Light-FIG-10

PRE-INSTALL EMERGENCY FUNCTION TEST

V-TAC-VT-8603-20W -LED-Dome-Light-FIG-11

  • Connect the AC cable according to the diagram.
  • Press the test button on the driver. The emergency function will be activated, and the charging indication will be off.
  • Disconnect the battery pack, the charging indicated LED is off.

NOTE: After installation, allow 36 hours to ensure full battery charge and then interrupt the supply.

SENSOR SETTINGS

V-TAC-VT-8603-20W -LED-Dome-Light-FIG-12

  • Detection Area – It can be adjusted by combining DIP switches for specific applications [FIG 1].
  • Hold Time – Time period during which the light will be ON after the last detection [FIG 2].
  • Daylight Threshold – Daylight sensor priors motion sensor. Set Threshold for Specific Needs. If disabled, only the motion sensor will work [FIG 3].

APPLICATION

[FUNCTION DEMO – DIMMABLE CONTROL/CORRIDOR FUNCTION]

V-TAC-VT-8603-20W -LED-Dome-Light-FIG-13

  • When motion is detected, but the daylight is sufficient, the light will remain OFF.
  • When motion is detected, and the daylight is insufficient, the light will be ON.V-TAC-VT-8603-20W -LED-Dome-Light-FIG-`14
  • After a stand-by period, the light will switch OFF.