MOUNTING

RECOMMENDATIONS

Install UNILEDLIGHT ceiling lights on surface with sufficient load bearing capacity.

Model Dimensions LxWxH (mm) Weight (g)
UNILEDLIGHT 18.24 R Ø 130 x 12 140
UNILEDLIGHT 18.24 RB Ø 130 x 12 140
UNILEDLIGHT 12.24 L 300 x 54 x 12 400
UNILEDLIGHT 12.24 LB 300 x 54 x 12 400
UNILEDLIGHT 26.24 L 600 x 54 x 12 800
UNILEDLIGHT 26.24 LB 600 x 54 x 12 800

Mounting depending on model:

UNILEDLIGHT 18.24 R / RB UNILEDLIGHT 12.24 L / LB UNILEDLIGHT 26.24 L / LB
3 screws on front side (included) 2 screws on front side (included) 2 screws on front side + 2 additional support brackets (6 screws included)
Fix the ceiling light on a flat surface thanks to its 3 screws
  • Take off protection caps situated on both ends
  • Fix the ceiling light thanks to the 2 screws
  • Put back protection caps
  • Take off protection caps situated on both ends
  • Fix the ceiling light thanks to the 2 screws
  • Put back protection caps   Additional fixing: 2 plastic support brackets
Mounting Mounting Mounting

WIRING

UNILEDBAR can operate:

  • On a 12V battery
  • On a 24V battery
  • On a DC voltage between 9V and 30V
  • Red cable to be connected on positive (+) terminal
  • Black cable to be connected on negative (-) terminal
    Wiring

OPERATING

Models with integrated switch: 

Switch on/off light: slightly press touch button
Light adjustment: keep touch button pressed until wanted beam.

Model without integrated switch: 

Switch on/off: press on your remote switch
Light adjustment: possible if the switch has this function.

TROUBLESHOOTING, CAUSES, SOLUTIONS

Error message Causes Solution
Light does not switch on Battery load < 9V Charge your battery. LED light operates only when the battery voltage is minimum 9V.
Wrong wiring Check your electrical connections (polarity, crimp)

TECHNICAL CHARACTERISTICS

  UNILEDLIGHT 18.24 RB UNILEDLIGHT 12.24 LB UNILEDLIGHT 26.24 LB
SYSTÈM

|

|

|

Technology

|

LED

|

Operating voltage

|

10-30V DC

|

Max power 18W 12W 26W
Real consumption 9W 10W 15W
BATTERY

|

|

|

Battery voltage

|

12/24V

|

LIGHT

|

|

|

Number of leds 91 x 0.2 W 58 x 0.2 W 134 x 0.2 W
Lumens 650 lm 400 lm 600 lm
Adjustable brightness

|

Yes

|

Beam

|

Large 120°

|

Color Cold white 5800-6250 K Neutral white 3800-4250K Neutral white 3800-4250K
Lifespan

|

>50 000 hours

|

MECHANICAL CHARACTERISTICS

Dimensions in mm (Lxwxh) Ø 130 x h 12 300 x 54 x 12 600 x 54 x 12
Weight in g 140 275 550
Material

|

Polycarbonate

|

Switch integrated

|

No

|

Cable

|

|

|

Length

|

22 cm

|

Type

|

2 single strand cables : black and red

|

Section

|

2 x 0,33mm²

|

Operating temperature

|

-20°C / +80°C

|

Protection rate

|

IP67

|

Warranty

|

2 years

|

  UNILEDLIGHT 18.24 RB UNILEDLIGHT 12.24 LB UNILEDLIGHT 26.24 LB
SYSTÈM

|

|

|

Technology

|

LED

|

Operating voltage

|

10-30V DC

|

Max power 18W 12W 26W
Real consumption 9W 10W 15W
BATTERY

|

|

|

Battery voltage

|

12/24V

|

LIGHT

|

|

|

Number of leds 91 x 0.2 W 58 x 0.2 W 134 x 0.2 W
Lumens 650 lm 400 lm 600 lm
Adjustable brightness

|

Yes

|

Beam

|

Large 120°

|

Color Cold white 5800-6250 K Neutral white 3800-4250K Neutral white 3800-4250K
Lifespan

|

>50 000 hours

|

Dimensions in mm (Lxwxh) Ø 130 x h 12 300 x 54 x 12 600 x 54 x 12
Weight in g 140 275 550
Material

|

Polycarbonate

|

Integrated switch

|

Yes, touch button

|

Cable

|

|

|

Length

|

22 cm

|

Type

|

2 single strand cables : black and red

|

Section

|

2 x 0,33mm²

|

Operating temperature

|

-20°C / +80°C

|

Protection rate

|

IP67

|

Warranty

|

2 years

|

DECLARATION OF CONFORMITY

UNITECK testifies that the LED lights described in this manual are manufactured in compliance with the EMC (electromagnetic compatibility standard) European directive and the 10.05 regulation (E-mark R10 05).

They comply to the harmonized standards: 

  • EN 55015 : 2013
  • EN 61547 : 2009
  • EN 61000-3-3 : 2006 + A1: 2009 + A2 : 2009
  • EN 61000-3-3 : 2013

CE date of tagging: may 2022.

UNITECK
1 Avenue de Rome
Immeuble cassis
ZAE via Europa
34500 Vendres
FRANCE

Symbol

WARRANTY

Warranty covers any defect, manufacturing defects for 2 years from the date of its purchase (parts and labour).

Warranty does not cover:

  • normal wear of parts (Ex.: cables, etc.).
  • panel-module/battery voltage errors, incidents due to inappropriate use, fall, disassembly or any damages due to transport.

In case of failure, return the product to your distributor by attaching:

  • the dated proof of purchase (receipt, bill…)
  • explanatory note of the failure

Caution: Our after-sales service does not accept carriage forward/ collected returns.
After the warranty, our after-sales service ensures repairs after acceptance of a quotation.

Customer Support

After-sales service contact:
UNITECK

1 Avenue de Rome
Zae Via Europa – Immeuble le Cassis
34350 Vendres -France
E-mail : [email protected]

www.uniteck.fr 13

Logo

Leave a Comment