Product Information

Ultrasonic Thickness Gauge

The Ultrasonic Thickness Gauge is available in three models:
AS840, AS850, and AS860. It is designed to measure the thickness of various materials, with a measuring range of 1.2mm to 225mm (Steel). The gauge operates at a frequency of 5MHz and has an accuracy resolution of 1000~9999m/s. It features sound velocity measuring and storage capabilities, with the ability to store up to 12 groups of data. The gauge also includes a backlight display, auto zero calibration, auto linear compensation, coupling indicator, and battery indication. It can be powered by a 9V battery and has a net weight of 200g.

Differential Pressure Meter Film / Coating Thickness Gauge

The Differential Pressure Meter Film / Coating Thickness Gauge is available in two models:
AS510 and AS930. It is designed to measure differential pressure and film/coating thickness. The AS510 model has a measuring range of hPa, mbar, mmH2O, mmHg, inH2O, inHG, m/s, fpm, while the AS930 model has a measuring range of 0~1800m. Both models operate on 3*1.5V AAA batteries and feature a backlight display, alarm buzzer, zero/two-point/basic calibration, single/continuous/standard deviation measurement, data storage and recall, data analysis, and metric/imperial switchable units.

Film / Coating Thickness Gauge

The Film / Coating Thickness Gauge is available in two models:
AS931 and AS931. Both models have a measuring range of 0~1800m and operate on a 9V battery. They feature a measuring principle of magnetic induction, with an accuracy resolution of 0.1m/1m. The gauges have a minimum curvature radius of Convex=1.5mm and Concave=9mm, a base sample diameter of 7mm, and a base substrate thickness of 0.5mm. They also include a backlight display, alarm buzzer, zero/two-point/basic calibration, single/continuous/standard deviation measurement, data storage and recall, data analysis, max & min measuring, AVG & DFR measuring, and metric/imperial switchable units.

Ultrasonic Thickness Gauge

SPECIFICATIONS

AS840 AS850 AS860
Transducer Φ10mm 5MHz Φ10mm 5MHz / 2.5MHz Φ 6mm 5MHz / Φ10mm 5MHz
Measuring Range 1.2~225mm(Steel) 1.2~225mm(Steel) 1.2~225mm(Steel)
Accuracy ±(1%H±0.1mm) ±(1%H±0.1mm) ±(1%H±0.1mm)
Resolution 0.1mm 0.1mm 0.1mm
Sound Velocity 1000~9999m/s 1000~9999m/s 1000~9999m/s
Operating Frequency 5MHz 5MHz 5MHz
Operation Condition 0°C~40°C 0°C~40°C 0°C~40°C
Minimum Limit For Tube Measuring   Ф20*3mm(Steel)  
Thickness Data Storage 10 groups 10 groups 12 groups
Sound Velocity Measuring & Storage 12 groups 12 groups 12 groups
Backlight Display
Auto Zero Calibration
Auto linear compensation
Coupling Indicator
Battery Indication
Auto/Manual Power Off
Max / Min Thickness Alarm Setup
12 Sound Velocities For

Different Material

Metric / Imperial Switchable
GENERAL CHARACTERISTICS & PACKING INFORMATION
Power 9V battery 9V battery 9V battery
Product Net Weight 200g 210g 240g
Product Size 150 x 80.5 x 34mm 150 x 80.5 x 34mm 150 x 80.5 x 34mm
Packing Gift box Gift box Gift box
Standard Quantity / Carton 24 10 10
Standard Carton Size 47 x 38 x 55cm 39x 32 x 44cm 39x 32 x 44cm
Standard Carton Gross Weight 19.5kg 11.0kg 11.0kg

Differential Pressure Meter

Measuring Range 0~100hPa

0~45.15 inH²O

 

 

 

Accuracy

±0.03 hPa(0~0.30hPa)

±0.05 hPa(0.31~1.0hPa)

±(1.5%+0.1hPa) remaining

±0.01 inH²O(0.00~0.12inH²O)

±0.02 inH²O(0.13~0.40inH²O)

±(1.5%+0.4inH²O) remaining

Resolution 0.01hPa / 0.01inH²O
Measuring speed 0.5 sec
Units hPa, mbar, mmH2O,

mmHg, inH2O, inHG, m/s, fpm

Operation

Condition

0~50°C / 32~122°F
GENERAL CHARACTERISTICS & PACKING INFORMATION
Power 3*1.5V AAA batteries
Product Net

Weight

71.5g
Product Size 124.8 x 49.8 x 25.6mm
Packing Gift box
Standard

Quantity / Carton

40
Standard Carton

Size

52.5 x 40 x 49cm

SMART-SENSOR-AS840-Ultrasonic-Thickness-Gauge-FIG- (1)

Film / Coating Thickness Gauge

SPECIFICATIONS AS930 AS931
Measuring Range 0~1800μm
Measuring Principle Magnetic Induction
Accuracy ±(3%H±1μm)
Resolution 0.1μm / 1μm
Minimum Curvature Radius Convex=1.5mm Concave=9mm
Base Sample Diameter Φ7mm
Base Substrate Thickness 0.5mm
Backlight Display
Alarm Buzzer
Zero/Two Point/Basic Calibration
Single / Continuous / Standard

Deviation Measurement

Data Storage & Recall
Data Analysis
Max & Min Measuring
AVG & DFR Measuring
Data Storage 15 groups 15 groups
Metric / Imperial Switchable
Battery Indication
Auto Power Off
Operation Condition 0°C~40°C (without strong magnetic)
GENERAL CHARACTERISTICS & PACKING INFORMATION
Power 9V battery 9V battery
Product Net Weight 147g 155g
Product Size 183x67x30mm 159x66x31mm
Packing Gift box Gift box
Standard Quantity / Carton 10 10

SMART-SENSOR-AS840-Ultrasonic-Thickness-Gauge-FIG- (2)

Product Usage Instructions

Ultrasonic Thickness Gauge

  1. Ensure the gauge is powered by inserting a 9V battery. Select the desired model: AS840, AS850, or AS860.
  2. Place the transducer on the material surface to be measured.
  3. Read the thickness measurement displayed on the gauge.
  4. If necessary, store the measurement data by pressing the appropriate storage button.
  5. Perform sound velocity measurements and storage as needed.
  6. Use the backlight display for better visibility in low light conditions.
  7. Perform auto zero calibration and auto linear compensation when required.
  8. Monitor the coupling indicator to ensure proper contact between the transducer and material surface.
  9. Check the battery indication to ensure sufficient power for accurate measurements.
  10. Choose between auto or manual power off options for convenience.
  11. If needed, set up max/min thickness alarms for specific measurement requirements.
  12. Refer to the user manual for specific instructions on using the gauge with different materials and switching between metric and imperial units.
    SPECIFICATIONS AR850 AR860
    Transducer Φ10mm 5MHz Φ10mm 2.5MHz Φ6mm 5MHz Φ10mm 5MHz
    Measuring Range 1.2~225mm(Steel) 1.00~300mm(Steel)
    Accuracy ±(1%H±0.1mm) ±(1%H±0.1mm)
    Resolution 0.1mm 0.1mm
    Sound Velocity 1000~9999m/s 1000~9999m/s
    Operating Frequency 5MHz / 2.5MHz 5MHz
    Operation Condition 0°C~40°C 0°C~40°C
    Minimum Limit For Tube Measuring Φ20 x 3mm(Steel) Φ15 x 2mm(Steel) (Φ6)

    Φ20 x 3mm(Steel) (Φ10)

    Data Storage 10 groups 12 groups
    Sound Velocity Measuring & Storage 12 groups 12 groups
    Backlight Display
    Auto Zero Calibration
    Auto linear compensation
    Coupling Indicator
    Battery Indication
    Auto/Manual Power Off
    Max / Min Thickness Alarm Setup
    12 Sound Velocities For Diff. Material
    GENERAL CHARACTERISTICS & PACKING INFORMATION
    Power 3*1.5V AAA batteries 3*1.5V AAA batteries
    Product Net Weight 275g 275g
    Product Size 153 x 75 x 35mm 153 x 75 x 35mm
    Packing Gift box Gift box
    Std Quantity / Carton 12 12
    Std Carton Size 52 x 43 x 32.5cm 52 x 43 x 32.5cm
    Std Carton G• Weight 16.3kg 16.3kg

Differential Pressure Meter Film / Coating Thickness Gauge

  1. Insert 3*1.5V AAA batteries to power the gauge.
  2. Select the desired model: AS510 or AS930.
  3. Place the gauge in the desired measurement location.
  4. Read the differential pressure or film/coating thickness measurement displayed on the gauge.
  5. Use the backlight display for better visibility in low light conditions.
  6. Be aware of alarm buzzers indicating specific conditions or thresholds.
  7. Perform zero/two-point/basic calibration as required for accurate measurements.
  8. Select the appropriate measurement mode: single, continuous, or standard deviation.
  9. Store and recall measurement data as needed, and perform data analysis if required.
  10. Refer to the user manual for specific instructions on using the gauge with different units and power management settings.SMART-SENSOR-AS840-Ultrasonic-Thickness-Gauge-FIG- (3)

Film / Coating Thickness Gauge

  1. Insert a 9V battery to power the gauge.
  2. Select the desired model: AS931 or AS931.
  3. Place the gauge in the desired measurement location.
  4. Read the film/coating thickness measurement displayed on the gauge.
  5. Use the backlight display for better visibility in low light conditions.
  6. Be aware of alarm buzzers indicating specific conditions or thresholds.
  7. Perform zero/two-point/basic calibration as required for accurate measurements.
  8. Select the appropriate measurement mode: single, continuous, or standard deviation.
  9. Store and recall measurement data as needed, and perform data analysis if required.
  10. Switch between metric and imperial units based on the measurement requirements.
  11. Monitor the battery indication to ensure sufficient power for accurate measurements.
  12. Enable auto power off for power-saving purposes.
  13. Refer to the user manual for specific instructions on using the gauge with different materials and measurement scenarios.
    SPECIFICATIONS AR930 AR931 AR932
    Measuring Range 0~1800μm 0~1500μm
    Measuring Principle Magnetic Induction Magnetic Induction & Eddy current
    Accuracy ±(3%H±1μm) ±(1.8%um±2um)(0-500um) ;

    ±(2.2%um±2um) (500-1500um)

    Resolution 0.1μm / 1μm 0.1μm / 1μm
    Minimum Curvature Radius Convex=1.5mm Concave=9mm Convex=5mm Concave=30mm
    Base Sample Diameter Φ7mm 25x25mm
    Base Substrate

    Thickness

    0.5mm Magnetic : 0.2mm ;

    Non-magnetic : 0.05mm

    Auto-identify Substrate Material
    Backlight Display
    Alarm Buzzer
    Zero / Two Point / Basic Calibration
    Single / Continuous / Standard

    Deviation Measurement

    Data Storage & Recall
    Data Analysis
    Max & Min Measuring
    AVG & DFR Measuring
    Data Storage 15 groups 15 groups 20 groups
    Metric / Imperial Switchable
    Battery Indication
    Auto Power Off
    Operation Condition 0°C~40°C (without strong magnetic) 0°C~50°C (without strong magnetic)
    GENERAL CHARACTERISTICS & PACKING INFORMATION
    Power 9V battery 9V battery 2*1.5V AAA batteries
    Product Net Weight 147g 245g 75g
    Product Size 183 x 67 x 30mm 153 x 75 x 35mm 119 x 50 x 30mm
    Packing Aluminum Box Aluminum Box Gift box
    Std Quantity / Carton 12 12 40
    Std Carton Size 52 x 43 x 32.5cm 52 x 43 x 32.5cm 52.5 x 40 x 49cm
    Standard Carton Gross Weight 13.5kg 13.5kg 20kg

    SMART-SENSOR-AS840-Ultrasonic-Thickness-Gauge-FIG- (4)

Leave a Comment