Specifications
- Operating Voltage: 220-240V AC 50Hz
- Maximum Power Consumption: Max. 1,200W
- Protection Type: IP20
- Protection Class: II
- Motion Detection Speed: Not specified
- Operating Temperature: Not specified
- Humidity: Not specified
Product Usage Instructions
General Safety Instructions
- Danger: Have the installation of this product done by a professional in accordance with applicable electrical and safety regulations.
- Caution: Keep this product away from children and animals! The contents of the packaging can pose a choking hazard.
Function of the Motion Detector
The motion detector is designed to detect movement in its detection area and control the operation of connected devices, such as lights.
Installation Recommendations (Fig.1b)
- Diameter of the mounting hole: Not specified
- Maximum thickness of the mounting surface: Not specified
- Depth of installation: Not specified
Mounting the Motion Detector
Follow the steps below to mount the motion detector
- Choose a suitable location for the motion detector.
- Ensure that the installation area is clean and free from obstructions.
- Use appropriate tools to create a mounting hole according to the specified diameter.
- Securely attach the motion detector to the mounting surface using screws or other suitable fasteners.
Connecting the Ground Wire (PE)
If connecting a lamp with an earth contact without using a junction box, bridge the ground wire of the lamp with the help of an additional clamp in the housing of the motion detector.
Operating Instructions
- Set the sensitivity of the motion detector according to the ambient light conditions using the provided setting.
- Adjust the time delay for the operation of connected devices (e.g., lights) after motion is detected. The time can be set between approximately 10 seconds and 30 minutes.
- Perform a function test to ensure proper operation of the motion detector. Make sure the detector is not covered and that the detection area is not obstructed by large objects.
Function Test
- Make sure the motion detector is not covered.
- Ensure that the detection area is not restricted by objects such as furniture.
- To set the detection range and perform a function test during daylight, adjust the knobs to the positions shown in the illustration.
- After a warm-up phase of approximately 30 seconds, the motion detector will be activated. If no further motion is detected in the sensor’s detection area, it will switch off.
FAQ
- Q: What is the maximum power consumption of this product?
A: The maximum power consumption is 1,200W. - Q: What is the operating voltage of this product?
A: The operating voltage is 220-240V AC 50Hz.
Manual
Thank you for choosing a product of SEBSON. Please read the instructions carefully and keep them for looking up before start-up this product. A long and failure-free operation can only be guaranteed if the installation and start-up is done properly. Before starting up this product, please check for external damage. In case of visible external damage we immediately dis-advise the start-up of this product! Please remove all packaging material of this product before the first start-up an and check the content for completeness!
Intended use
This SEBSON motion detector has an IR sensor that detects the heat radiation of moving objects and activates e.g. a connected light
Scope of delivery
- 1 motion detector
- Screws for fixing (2 pieces)
- Dowels Ø 6mm (2 pieces)
General safety information
- Danger: The installation of this product may be done only by a qualified person according the valid regulations for electrical installation!
- Danger: If the power cables are damaged or come into contact with wetness, immediately disconnect the product from the power supply and ensure that it cannot be switched on again!
- Danger of suffocation: Please keep this product away from children and animals. The packaging contains small parts that can be swallowed!
- Caution: Avoid overloading the device, an overload can damage the device or cause a short circuit!
Therefore, please note the maximum power consumption in the technical data!
- The remodeling of this product is not allowed! The proper and safe functioning of the device can no longer be guaranteed if it is modified! In addition, this will invalidate the warranty claim!
- The manufacture does not accept any responsibility for injuries or damage resulting from improper use of this product!
- Any other use than the description may result in damage to the product. So the dangers are such as electric shock, short circuit, fire etc.
- We reserve the right to make changes to the product, the packaging or the operating instructions as well as printing errors.
- This product is only suited for indoor-use and not for outdoor-use!
- Protect the product from external damage, heavy dirt, moisture and excessive heat!
- In order that the warranty claim does not expire please use only the supplied items. Repairs may only be done by an expert and only by using original spare parts!
- In commercial institutions, the accident prevention regulations of the professional trade association for electrical equipment and facilities must be adhered to.
Instruction for installation (Fig 5)
- Danger: Before installing please make sure that the circuit is interrupted! For installation, the work on the mains voltage is required. Please remove the associated mains fuse or deactivate the switch fuse! Check by using a voltage tester if the line is de-energized. Make sure that the current circuit will not closed during the installation!
- Danger: The installation of this product may be done only by a qualified person according the valid regulations for electrical installation!
Attention
Before drilling the mounting holes, make sure that there are no gas, electricity or water pipes at the drilling location that could be damaged by this!
- Please observe the safety instructions and technical data before installing this product!
- Note on installation:
- L: Live wire (black or brown)
- N: Neutral conductor (blue or grey)
- This device is only suitable for ceiling mounting!
- Observe a minimum distance of 2 meters when commissioning several motion detectors.
- For optimum range, select the mounting height recommended in the “Technical Data”.
- 2 units in a parallel connection (see Fig.4a)
- Permanent switch-on of a connected device with an additional switch connected in parallel (see Fig.4b).
The following environments or surfaces are not suitable for mounting, as they may impair the detection of thermal radiation (see Fig. 2)
- Metal surfaces e.g. metal door frames
- In the immediate vicinity of electronic devices such as computers, monitors etc
- Heat sources e.g. radiant heaters, radiators or lamps
- In the vicinity of e.g. fume cupboards or fans
- Within the radiation range of luminaires (minimum distance from luminaires >50cm)
Function of the motion sensor
The sensor integrated in this device detects heat radiation from moving bodies, e.g. people or animals, and transmits this as an electrical impulse to a connected light, for example. This device then switches itself on. The detection of heat radiation can be limited by large furniture, glass panes or very high ambient temperatures of over 40°C, for example in summer.
Detection area (Fig 3)
The detection range of the motion detector is approx. 8m and 360° (free area) at a mounting height of 2.2-4m at the ceiling. In closed rooms the detection distance can be lower, according to room layout.
Connection of the protective conductor (PE) | |
When connecting a lamp with protective conductor contact, the protective conductor must be bypassed from the supply line to the lamp with the aid of an additional terminal in the in-wall socket |
Sensitivity when switching (with regard to the ambient brightness) | |
![]() |
This setting control can be used to regulate the switch-on sensitivity of this unit depending on the ambient brightness (between 3 and 2.000 LUX). |
Time setting (switching off delay) | |
![]() |
The duration of the operating time can be set continuously from approx. 10s to 30min. The timer is restarted if a movement from the sensor is detected before the set time has elapsed. |
Function test |
![]() |
Ensure that the motion detector is not obscured. Ensure that the coverage area is not restricted by items such as through large furniture. To set the detection range and the daylight test, turn the knobs to the positions shown. The motion detector is activated after a warm-up phase of approx. 30s. If no further movement takes place in the sensing area of the sensor, the sensor switches off. |
Installation recommendation (Fig 1b) | |
Mounting hole | Ø63-66mm |
Maximum thickness of mounting surface | ≤10mm |
Mounting depth | ≥25mm |
Technical Data | |
Operating voltage | 220 -240V AC 50Hz |
Maximum power consumption: | Max. 1.200W Max. 600W![]() |
Electrical protection: | IP20 |
Protection class: | II |
Detection moving speed: | 0,6-1,5m/s |
Ambient temperature: | -20° – +40°C |
Humidity: | <93% |
Possibilities of adjustments: | |
Detection area: | Max.8m (<24°C)/360° |
Sensitivity when switching (with regard to the ambient brightness): | <3-2.000LUX |
Time setting (switching off delay): | Min. 10s +/- 3s – Max. 30min +/-2min |
Information for private households (WEEE): |
The Electrical and Electronic Equipment Act (WEEE) contains a large number of requirements for the handling of electrical and electronic equipment. The most important ones are summarised here.
|
Cleaning |
Danger: Before start cleaning the product interrupt the current circuit by switching off the circuit breaker or unscrew the fuse! Use a slightly moistened cloth for cleaning. In order not to damage the product, it is essential to avoid water penetrating into the housing! Never clean the device under running water! Do not use solvent- containing cleaner for cleaning. |
Address
- SEBSON
- Sebastian Sonntag
- Walter-Behrendtstr.10
- 44329 Dortmund
- Germany
- [email protected]
- VAT-Nr.: GB179436663
- WEEE-Reg.-ID.: 500617