  • Product Name: Air Handler Model A TEM4A0B31M31SB
  • Manufacturer: Not specified
  • Model Number: TEM4A0B31-SUB-1D-EN
  • Dimensions: Crated (In.) HxWxD 48-1/4 x 22-1/2 x 25-1/2, Uncrated 46-3/4 x 18-1/2 x 21-1/8
  • Weight: Shipping (Lbs.) / Net (Lbs.) 145/138
  • Rated Voltage/Phase/Hertz: 208-230/1/60
  • Refrigerant: R-410A
  • Heater Model Numbers: BAYHTR1504BRK, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505LUG, BAYHTR1508BRK, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510LUG, BAYHTR1517BRK, BAYHTR3517LUG, BAYHTR3510LUG, BAYHTR1523, BAYHTR1525

Product Usage Instructions

To install and use the Air Handler Model A TEM4A0B31M31SB:

  1. Ensure that the unit is approved for installation clearances to combustible material as stated on the unit rating nameplate.
  2. Refer to the Split System Outdoor Unit Product Data Guides for performance data and approved combinations of Air Handlers and Heaters.
  3. Install the air handler according to the outline drawing provided in the user manual.
  4. Connect the refrigerant line using a 3/8-inch coupling or connection size for the liquid line and a 3/4-inch coupling or connection size for the gas line.
  5. Connect the ducts to the indoor fan, which is a centrifugal type with a diameter width of 11 x 8 inches and one direct drive at five speeds. Refer to the fan performance table for more information.
  6. Install the heater racks and connect them to the appropriate heater model number as listed in the user manual.
  7. Turn on the air handler and adjust the airflow speed according to your needs using the minimum heat speed tap. Refer to the heater pressure drop table for more information.

Outline Drawing

S-G-TORRICE-TEM4A0B31M31SB-Convertible-Air-Handler-FIG-1

PRODUCT DIMENSIONS
Air Handler Model A B C D E F H Flow Control Gas Line Braze
TEM4A0B31M31SB 46.77 18.50 16.50 16.75 4.68 7.33 20.09 TXV 3/4
All dimensions are in inches

Product Specifications

MODEL TEM4A0B31M31SB
RATED VOLTS/PH/HZ 208-230/1/60
RATINGS(a) See O.D. Specifications
INDOOR COIL — Type Plate Fin
Rows — F.P.I. 4 – 14
Face Area (sq. ft.) 3.44
Tube Size (in.) 3/8
Refrigerant Control TXV
Drain Conn. Size (in.)(b) 3/4 NPT
DUCT CONNECTIONS See Outline Drawing
INDOOR FAN — Type Centrifugal
Diameter-Width (In.) 11 X 8
No. Used 1
Drive – No. Speeds Direct – 5
CFM vs. in. w.g. See Fan Performance Table
No. Motors — H.P. 1 – 1/3
Motor Speed R.P.M. 1050
Volts/Ph/Hz 208-230/1/60
F.L. Amps 2.8
FILTER  
Filter Furnished? (c) No
REFRIGERANT R-410A
Ref. Line Connections Brazed
Coupling or Conn. Size — in. Gas 3/4
Coupling or Conn. Size — in. Liq.  

3/8

DIMENSIONS H x W x D
Crated (In.) 48-1/4 x 22-1/2 x 25-1/2
Uncrated 46-3/4 x 18-1/2 x 21-1/8
WEIGHT  
Shipping (Lbs.) / Net (Lbs.) 145/138
  • These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
  • 3/4” Male Plastic Pipe (Ref: ASTM 1785–76)
  • Remote filter required.

Minimum Airflow CFM

TEM4A0B31M31SB
Heater Minimum Heat Speed Tap
  With Heat Pump Without Heat Pump
BAYHTR1504BRK, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505LUG  

Low

 

Low

BAYHTR1508BRK, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510LUG  

Med-High

 

Med-Low

BAYHTR1517BRK, BAYHTR3517LUG, BAYHTR3510LUG  

High

 

Med

Heater Pressure Drop Table TEM Air Handler Models

 

Airflow CFM

Number of Racks   Heater Racks
1 2 3 4 Heater Model No. of Racks
Air Pressure Drop — Inches W.G. BAYHTR1504 1
1800 0.02 0.04 0.06 0.14 BAYHTR1505 1
1700 0.02 0.04 0.06 0.14 BAYHTR1508 2
1600 0.02 0.04 0.06 0.13 BAYHTR1510 2
1500 0.02 0.04 0.06 0.12 BAYHTR3510 3
1400 0.02 0.04 0.06 0.12 BAYHTR1517 3
1300 0.02 0.04 0.05 0.11 BAYHTR3517 3
1200 0.01 0.04 0.05 0.10 BAYHTR1523 4
1100 0.01 0.03 0.05 0.09 BAYHTR1525 4
1000 0.01 0.03 0.04 0.09    
900 0.01 0.03 0.04 0.08    
800 0.01 0.03        
700 0.01 0.02        
600 0.01 0.02        

Performance and Electrical Data

  1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters.
  2. Heater model numbers may have additional suffix digits.

Table 1. Air Flow Performance

TEM4A0B31M31SB (a)
EXTERNAL STATIC

(in w.g)

AIRFLOW
Speed Taps: 208 – 230 VOLTS
  High Med-High Med † Med-Low Low
0.1 1192 1127 1070 995 940
0.2 1148 1079 1021 943 885
0.3 1103 1031 971 890 828
0.4 1057 980 919 834 767
0.5 1009 929 865 775 702
0.6 961 875 810 714 635
0.7 911 820 753 651 564
1.      Values are with wet coil, no filter, and no heaters

2.      CFM Correction for dry coil = Add 3%

3.      † = Factory Setting

4.      Low = Tap 1, Med-Low = Tap 2, Med = Tap 3, Med-High= Tap 4, High = Tap 5

  • For the TEM4A0B31M31SB in downflow applications, airflow must not exceed 1200 cfm due to condensate blow off.

Table 2. Electrical Data

TEM4A0B31M31SB
 

Heater Model No.

No. of Circuits/ Phases 240 Volt 208 Volt
Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protection
kW BTUH kW BTUH
No Heater       2.8 * 4 15     2.8 * 4 15
BAYHTR1504BRK BAYHTR1504LUG 1/1 3.8 13100 16.0 24 25 2.9 9800 13.8 21 25
BAYHTR1505BRK BAYHTR1505LUG 1/1 4.8 16400 20.0 29 30 3.6 12300 17.3 25 25
BAYHTR1508BRK BAYHTR1508LUG 1/1 7.7 26200 32.0 44 45 5.8 19700 27.7 38 40
BAYHTR1510BRK BAYHTR1510LUG 1/1 9.6 32800 40.0 54 60 7.2 24600 34.6 47 50
BAYHTR1517BRK-

Circuit 1 (a)

 

2/1

9.6 32800 40.0 54 60 7.2 24600 34.6 47 50
BAYHTR1517BRK-

Circuit 2

4.8 16400 20.0 25 25 3.6 12300 17.3 22 25
BAYHTR3510LUG 1/3 9.6 32800 23.1 32 35 7.2 24600 20.0 28 30
BAYHTR3517LUG 1/3 14.4 49100 34.6 46 50 10.8 36900 30.0 41 45
BAYHTR1517BRK

with single circuit power source kit

BAYSPEKT201A

 

1/1

 

14.4

 

49100

 

60.0

 

83

 

90

 

10.8

 

36900

 

51.9

 

73

 

80

* = Motor Amps
  • MCA and MOP for circuit 1 contain the motor amps.

Features and Benefits

  • Painted metal cabinet with captured foil face insulation
  • 2% or less air leakage
  • R-4.2 Insulating Value
  • Multi-Position UP/Down Flow, Horizontal Left /Right
  • ALL Aluminum Coil
  • Electric Heaters with polarized plug connections (sold as accessories)
  • R-410A Thermal Expansion Valve
  • ECM Motor ((33..55 –– 55 TToonn MMooddeellss ))
  • Low Voltage Pigtail Connections
  • Draw Through Design
  • Horizontal Drain pan
  • Fused 24V Power
  • 33-year warranty
  • 1100–year warranty registered
  • Optional extended warranty available

Important: Condensate management kit is required for all 5-ton air handler models installed in downflow applications. About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy-efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com.

The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

  • TEM4A0B31-SUB-1D-EN 16 Sep 2022 Supersedes TEM4A0B31-SUB-1C-EN (March 2022)