Rheem RP15AZ42AJ2NA Heat Pump System User Manual

Home » Rheem » Rheem RP15AZ42AJ2NA Heat Pump System User Manual

Heat Pumps
RP15AZ
The new degree of comfort®.
Endeavor™ Line Classic Plus® Series
iM Heat Pumps
User Manual

RP15AZ42AJ2NA Heat Pump System

RP15AZ
Cooling Efficiencies up to: 16 SEER2 / 11.7 EER2
Heating Efficiencies up to: 8.1 HSPF
Nominal Sizes: 1.5 to 5 Tons [5.3 to 17.6 kW] Cooling & Heating Capacities: 13.36 kBTU to 45.6 kBTU

*Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.

Features and Benefits

  • Two-Stage Scroll Compressor: Features two speeds (high and low) of cooling and heating, providing more precise temperature control, lower humidity and greater efficiency when compared to single stage compressors
  • 7 mm Condenser Copper Coil1: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • Inverted Reversing Valve: Allows for faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability
  • PlusOne® Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space — provides a minimum working area of 27-square inches for easier access
  • PlusOne®Triple Service Access: 15″ wide, industry leading corner service access, two fastener, removeable corner and individual louver panels — makes repairs easier and faster

Model Number Identification

RP15AZ
Heat Pumps

R P 15 A Z 18
Brand Product Category SEER2 Region Refrigerant Capacity
R – Rheem P – Heat Pump 15 – 15.2 SEER2 A – All Regions Z – R-410A 18 – 18,000  [5.28 kW] 24 – 24,000  [7.03 kW] 30 – 30,000  [8.79 kW] 36 – 36,000 [10.55 kW] 42 – 42,000 [12.31 kW] 48 – 48,000 [14.07 kW] 60 – 60,000 [17.58 kW]
A J 2 N A
Major Series Voltage Type Controls Minor Series
A – 1st Design J – 208/230/1/60 2 – 2+ Stage N – Non-Comm. A – 1st Design

[ ] Designates Metric Conversions

AVAILABLE MODELS DESCRIPTION
RP15AZ18AJ2NA Endeavor™ Line Classic Plus ® Series 1 1/2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
RP15AZ24AJ2NA Endeavor™ Line Classic Plus ® Series 2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
RP15AZ30AJ2NA Endeavor™ Line Classic Plus ® Series 2 1/2 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
RP15AZ36AJ2NA Endeavor™ Line Classic Plus ® Series 3 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
RP15AZ42AJ2NA Endeavor™ Line Classic Plus ® Series 3 1/2 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
RP15AZ48AJ2NA Endeavor™ Line Classic Plus ® Series 4 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60
RP15AZ60AJ2NA Endeavor™ Line Classic Plus ® Series 5 ton 15.2 SEER2 2-Stage iM Heat Pump-208/230/1/60

STANDARD EQUIPMENT

  • R-410A Refrigerant
  • Scroll Compressor
  • Field Installed Filter Drier
  • Front Seating Service Valves
  • Internal Pressure Relief Valve
  • Internal Thermal Overload
  • Long Line capability
  • Low Ambient capability with Kit
  • 3-4-5 Expanded Valve Space
  • Composite Basepan
  • 2 Screw Control Box Access
  • 15″ Access to Internal Components
  • Quick release louver panel design
  • No fasteners to remove along bottom
  • Optimized Venturi Airflow
  • Single row condenser coil
  • Powder coated paint
  • Rust resistant screws
  • QR code
  • External gauge ports
  • Service trays

General Data/Electrical Data

RP15AZ

General Data
MODEL NO. (-)P15AZ 18AJ2NA (-)P15AZ 24AJ2NA (-)P15AZ 30AJ2NA (-)P15AZ 36AJ2NA (-)P15AZ 42AJ2NA (-)P15AZ 48AJ2NA (-)P15AZ 60AJ2NA
Nominal Tonnage
Valve Connections
Liquid Line O.D. – in. 0.375 0.375 0.375 0.375 0.375 0.375 0.375
Suction Line O.D. – in. 0.75 0.75 0.75 0.75 0.875 0.875 0.875
Refrigerant (R410A) furnished oz.¹ 118 118 120 127 143 146 220
Compressor Type 2-stage Scroll
Outdoor Coil
Net face area – Outer Coil 10.9 10.9 19.5 21.5 21.5 21.5 32.5
Net face area – Inner Coil 10.5 10.5
Tube diameter – in. 0.276 0.276 0.276 0.276 0.276 0.276 0.375
Number of rows 2 2 1 1 1 1 1
Fins per inch 22 22 22 22 22 22 20
Outdoor Fan
Diameter – in. 20 20 24 24 24 24 26
Number of blades 2 2 3 3 3 3 3
Motor hp 1/6 1/6 1/5 1/5 1/5 1/5 1/5
CFM 2582 2582 4077 4206 4206 4206 5106
RPM 1075 1075 850 850 850 850 850
watts 145 145 222 246 246 246 294
Shipping weight – lbs. 157 157 209 221 247 247 298
Operating weight – lbs. 150 150 202 214 240 240 291
Electrical Data
Line Voltage Data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps)² 15 25 30 30 45 45 50
Minimum circuit ampacity5 11 15 18 20 26 28 31
Compressor
Rated load amps 8 11 14 15 20 21 24
Locked rotor amps 56 61 87 102 151 0 151
Condenser Fan Motor
Full load amps 0.75 0.75 1.0 1.0 1.0 1.0 1.0
Locked rotor amps 1.5 1.5 2.56 2.56 2.56 2.56 2.56
  1. Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
  2. HACR type circuit breaker of fuse.
  3. Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories/Weighted Sound Power

RP15AZ
Accessories

MODEL NO. (-) P15AZ18 (-) P15AZ24 (-) P15AZ30 (-) P15AZ36 (-) P15AZ42 (-) P15AZ48 (-) P15AZ60
Compressor crankcase heater* 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 Factory Standard
Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08
Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25
Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1
Low pressure control Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard
High pressure control Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard Factory Standard
Liquid Line Solenoid (24 VAC, 50/60 Hz) Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz) Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC
Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V
Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123-21

Weighted Sound Power Level (dBA)

UNIT SIZE – VOLTAGE, SERIES STANDARD RATING (DBA) TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125 250 500 1000 2000 4000 8000
RP15AZ18A 73 58.0 58.8 62.0 62.3 59.2 56.6 50.5
RP15AZ24A 73 56.6 59.6 62.2 62.1 58.8 55.4 50.8
RP15AZ30A 72 48.9 55.3 63.6 61.0 59.1 56.5 48.7
RP15AZ36A 74 51.2 56.4 63.1 63.8 60.8 57.4 56.5
RP15AZ42A 74 56.8 58.7 65.9 66.2 62.9 59.4 54.2
RP15AZ48A 74 57.3 56.6 64.1 64.0 61.1 58.0 56.5
RP15AZ60A 74 43.9 55.2 63.4 65.8 61.7 57.9 52.9

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

Unit Dimensions

RP15AZ
Unit Dimensions

 

MODEL NO.

OPERATING SHIPPING
H (Height) L (Length) W (Width) H (Height) L (Length) W (Width)
INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm
(-)P15AZ18AJ2NA 25.00 635.00 29.75 755.65 29.75 755.65 27.90 708.66 33.25 844.55 33.25 844.55
(-)P15AZ24AJ2NA 25.00 635.00 29.75 755.65 29.75 755.65 27.90 708.66 33.25 844.55 33.25 844.55
(-)P15AZ30AJ2NA 35.00 889.00 33.75 857.25 33.75 857.25 38.35 974.09 37.64 956.06 37.64 956.06
(-)P15AZ36AJ2NA 39.00 990.60 33.75 857.25 33.75 857.25 42.35 1075.69 37.64 956.06 37.64 956.06
(-)P15AZ42AJ2NA 39.00 990.60 33.75 857.25 33.75 857.25 42.35 1075.69 37.64 956.06 37.64 956.06
(-)P15AZ48AJ2NA 39.00 990.60 33.75 857.25 33.75 857.25 42.35 1075.69 37.64 956.06 37.64 956.06
(-)P15AZ60AJ2NA 51.00 1295.40 35.75 908.05 35.75 908.05 54.50 1384.30 39.37 1000.00 39.37 1000.00

[ ] Designates Metric Conversions

Clearances

RP15AZ

Refrigerant Line Size Information

RP15AZ

SINGLE AND TWO-STAGE HEAT PUMPS
UNIT SIZE MAX. LIQUID LINE SIZE SUCTION LINE SIZE OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH IN FEET
0-15 16-25 26-50 51-80 81-100 101-125 126-150
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER
1.5 TON 3/8″ 1/2″ 15 / 1 25 / 1 50 / 0.99 80 / 0.97 100 / 0.97 115 / 0.96 115 / 0.95
5/8″ 15 / 1 25 / 1 50 / 1 80 / 0.99 100 / 0.99 115 / 0.99 115 / 0.98
3/4″ 15 / 1 25 / 1 50 / 1 80 / 0.99 100 / 0.99 115 / 0.99 115 / 0.98
2 TON 3/8″ 5/8″ 15 / 1 25 / 1 50 / 0.99 80 / 0.98 100 / 0.97 100 / 0.96 95 / 0.95
3/4″ 15 / 1 25 / 1 50 / 1 80 / 0.99 100 / 0.99 100 / 0.99 95 / 0.98
2.5 TON 3/8″ 5/8″ 15 / 1 25 / 0.99 50 / 0.98 80 / 0.97 95 / 0.96 90 / 0.94 85 / 0.93
3/4″ 15 / 1 25 / 1 50 / 0.99 80 / 0.99 95 / 0.98 90 / 0.98 85 / 0.97
3 TON 3/8″ 5/8″ 15 / 1 25 / 0.99 50 / 0.97 80 / 0.95 85 / 0.94 80 / 0.92 75 / 0.9
3/4″ 15 / 1 25 / 1 50 / 0.99 80 / 0.98 85 / 0.98 80 / 0.97 75 / 0.96
7/8″ 15 / 1 25 / 1 50 / 1 80 / 0.99 85 / 0.99 80 / 0.99 75 / 0.98
3.5 TON 3/8″ 3/4″ 15 / 1 25 / 0.99 50 / 0.98 80 / 0.97 80 / 0.97 70 / 0.96 65 / 0.95
7/8″ 15 / 1 25 / 1 50 / 0.99 80 / 0.99 80 / 0.99 70 / 0.98 65 / 0.98
4 TON 3/8″ 3/4″ 15 / 1 25 / 0.99 50 / 0.98 75 / 0.97 70 / 0.96 60 / 0.95 50 / 0.94
7/8″ 15 / 1 25 / 1 50 / 0.99 75 / 0.99 70 / 0.98 60 / 0.98 50 / 0.97
5 TON 3/8″ 3/4″ 15 / 1 25 / 0.99 50 / 0.97 65 / 0.95 45 / 0.94 30 / 0.92 15 / 0.9
7/8″ 15 / 1 25 / 0.99 50 / 0.99 65 / 0.98 45 / 0.97 30 / 0.96 15 / 0.96

NOTES:

  1. Maximum Equivalent Line Length may not exceed 250′.
  2. Maximum Actual Line Length may not exceed 200′.
  3. Light Grey shaded areas are considered long line and may require accessories as recommended in Long Line Set Guide.
  4. Refer to supplemental Long Line Set Guide for applications that require liquid line size other than 3/8″.
  5. DO NOT use suction line traps in the suction riser as this adds additional unwanted pressure drop in the system.
SINGLE AND TWO-STAGE HEAT PUMPS
UNIT SIZE MAX. LIQUID LINE SIZE SUCTION LINE SIZE OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH IN METERS
0-5 5.5-8 8.5-15 15.5-24 24.5-30 30.5-38 38.5-46
MAXIMUM VERTICAL SEPARATION/CAPACITY MULTIPLIER
1.5 TON 3/8″ 1/2″ 5 / 1 8 / 1 15 / 0.99 24 / 0.97 30 / 0.97 35 / 0.96 35 / 0.95
5/8″ 5 / 1 8 / 1 15 / 1 24 / 0.99 30 / 0.99 35 / 0.99 35 / 0.98
3/4″ 5 / 1 8 / 1 15 / 1 24 / 0.99 30 / 0.99 35 / 0.99 35 / 0.98
2 TON 3/8″ 5/8″ 5 / 1 8 / 1 15 / 0.99 24 / 0.98 30 / 0.97 30 / 0.96 29 / 0.95
3/4″ 5 / 1 8 / 1 15 / 1 24 / 0.99 30 / 0.99 30 / 0.99 29 / 0.98
2.5 TON 3/8″ 5/8″ 5 / 1 8 / 0.99 15 / 0.98 24 / 0.97 29 / 0.96 27 / 0.94 26 / 0.93
3/4″ 5 / 1 8 / 1 15 / 0.99 24 / 0.99 29 / 0.98 27 / 0.98 26 / 0.97
3 TON 3/8″ 5/8″ 5 / 1 8 / 0.99 15 / 0.97 24 / 0.95 26 / 0.94 24 / 0.92 23 / 0.9
3/4″ 5 / 1 8 / 1 15 / 0.99 24 / 0.98 26 / 0.98 24 / 0.97 23 / 0.96
7/8″ 5 / 1 8 / 1 15 / 1 24 / 0.99 26 / 0.99 24 / 0.99 23 / 0.98
3.5 TON 3/8″ 3/4″ 5 / 1 8 / 0.99 15 / 0.98 24 / 0.97 24 / 0.97 21 / 0.96 20 / 0.95
7/8″ 5 / 1 8 / 1 15 / 0.99 24 / 0.99 24 / 0.99 21 / 0.98 20 / 0.98
4 TON 3/8″ 3/4″ 5 / 1 8 / 0.99 15 / 0.98 23 / 0.97 21 / 0.96 18 / 0.95 15 / 0.94
7/8″ 5 / 1 8 / 1 15 / 0.99 23 / 0.99 21 / 0.98 18 / 0.98 15 / 0.97
5 TON 3/8″ 3/4″ 5 / 1 8 / 0.99 15 / 0.97 20 / 0.95 14 / 0.94 9 / 0.92 5 / 0.9
7/8″ 5 / 1 8 / 0.99 15 / 0.99 20 / 0.98 14 / 0.97 9 / 0.96 5 / 0.96

NOTES:

  1. Maximum Equivalent Line Length may not exceed 76 Meters.
  2. Maximum Actual Line Length may not exceed 61 Meters.
  3. Light Grey shaded areas are considered long line and may require accessories as recommended in Long Line Set Guide.
  4. Refer to supplemental Long Line Set Guide for applications that require liquid line size other than 3/8″.
  5. DO NOT use suction line traps in the suction riser as this adds additional unwanted pressure drop in the system.

Performance Data

Performance Data@ AHRI Standard Conditions – Cooling

DESIGNATED TESTED COMBINATION (DTC)
OUTDOOR UNIT AIR HANDLER TOTAL CAPACITY BTU/H [kW] NET SENSIBLE BTU/H [kW] NET LATENT BTU/H [kW] SEER2 EER2 INDOOR CFM [L/S] 47 DEGREE HEATING CAPACITY BTU/H [KW] 47
DEGREE COP
17 DEGREE HEATING CAPACITY BTU/H [KW] 17
DEGREE COP
REGION IV HSPF2
(-)P15AZ18AJ2N RH2TZ2417STANN 17,100 [5.0] 13,100 [3.8] 4,000 [1.2] 15.2 11.7 625 [295.0] 17,100 [5.0] 3.87 11,600 [3.4] 2.6 7.8
(-)P15AZ24AJ2N RH2TZ2417STANN 22,800 [6.7] 17,400 [5.1] 5,400 [1.6] 15.2 11.7 775 [365.8] 22,600 [6.6] 3.88 15,600 [4.6] 2.8 7.8
(-)P15AZ30AJ2N RH2TZ3617STANN 28,400 [8.3] 21,800 [6.4] 6,600 [1.9] 15.2 11.7 900 [424.8] 28,400 [8.3] 3.62 19,700 [5.8] 2.6 7.8
(-)P15AZ36AJ2N RH2TZ3617STANN 34,200 [10.0] 26,200 [7.7] 8,000 [2.3] 15.2 11.7 1,050 [495.5] 34,200 [10.0] 3.62 24,400 [7.2] 2.7 7.8
(-)P15AZ42AJ2N RH2TZ4821STANN 40,000 [11.7] 30,500 [8.9] 9,500 [2.8] 15.2 11.7 1,325 [625.3] 39,500 [11.6] 3.95 28,200 [8.3] 2.9 7.8
(-)P15AZ48AJ2N RH2TZ4821STANN 45,500 [13.3] 35,000 [10.3] 10,500 [3.1] 15.2 11.7 1,450 [684.3] 45,000 [13.2] 3.92 33,200 [9.7] 2.9 7.8
(-)P15AZ60AJ2N RH2TZ6024STANN 57,000 [16.7] 43,500 [12.7] 13,500 [4.0] 15.2 11.7 1,800 [849.5] 57,000 [16.7] 4.04 42,500 [12.5] 3.0 7.8

NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, will be accessible from the AHRI website: www.ahridirectory.org later this year.
[ ] Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required) ……………………………Ten (10) Years
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
© 2023 Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.