PREMIUM LEVELLA PRF65DX Single Door Merchandiser Refrigerator User Manual

Home » PREMIUM LEVELLA » PREMIUM LEVELLA PRF65DX Single Door Merchandiser Refrigerator User Manual

PREMIUM-LEVELLA-logo

PREMIUM LEVELLA PRF65DX Single Door Merchandiser Refrigerator

PREMIUM-LEVELLA-PRF65DX-Single-Door-Merchandiser-Refrigerator-product

Product Information

This product is a single-door merchandiser refrigerator with models PRF65DX, PRF90DX, PRF125DX, PRF155DX, PRF657DX, PRF907DX, PRF1257DX, and PRF1557DX. The product is designed for indoor use only and has a glass door to display stored goods. It features a hermetic compressor with a broad range of starting voltage and a suitable ambient temperature of not higher than 40°C. The cooler system is designed to provide powerful refrigerating ability and energy-saving performance. The cooler has a thermal insulation layer made from hard polyurethane-foamed plastics that keep the contents cold. The product comes with a cabinet lock, a lamp box, a glass door, a temperature control knob, an evaporator, a shelf, and a panel foot, and has different production dimensions depending on the model.

Product Usage Instructions

Before using the product, read the user manual carefully to understand the basic knowledge, use instructions, fault diagnosis, and basic troubleshooting methods. The following are important safety instructions:

  • Keep all ventilation openings in the appliance enclosure or in the structure clear of obstruction.
  • Do not place the unit near any kind of heat source, inside air streams produced by ventilation fans, open doors and/or windows, or under direct sunlight.
  • The installation of this appliance must be carried out only by a suitably qualified person.

To level the unit, adjust the panel foot. When transporting the product, follow the schematic diagram for the demand size of product space. To operate the temperature control knob:

  1. Locate the temperature control knob.
  2. To increase the temperature, turn the knob clockwise.
  3. To decrease the temperature, turn the knob counterclockwise.
  4. Set the temperature to the desired level, between 0°C and 10°C.

Dear Customer

Dear users (customer), this manual contains the product’s basic knowledge, use instruction, fault diagnosis and basic trouble shooting methods. In order to better understand and use this product, please take good care of this manual and read it carefully.

Important safety instructions

  1. The range of operating voltage: 97V~130V. In order to avoid damaging the electrical performance of the compressor, please equip with a voltage stabilizer appliance of power not less than 500W, to protect the cooler when the voltage is lower than 97V or higher than 130V.
  2. Individual single-phase socket must be used. It should be reliably connected to a grounding wire. Caution: The grounding wire is not allowed to connect to a water pipe or a gas pipe.
  3. Strong base, strong acid, organic solvent and corrosive goods or those are easy to pollute
    to food are prohibited storing in the cooler; otherwise, it can cause corrosiveness or accident.
  4. Don’t raise the cooler or the shell of the electric parts, or it will cause the decline in insulation and cause corrosion.
  5. When the cooler will be not be used for a long time, disconnect the power and clean it. Please examine the circuit whether it is ok before reuse.
  6. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
  7. The appliance shall be disconnected from its power source during cleaning or maintenance and when replacing parts.
  8. The A-weighted emission sound pressure level is below 70Db(A).
  9. Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance.
  10. Flammable blowing gas of the cooler should be handled according to local regulations. Before you scrap the appliance, please take off the doors to prevent children trapped.

Caution:

  1. Risk of fire / flammable materials, taking care to avoid causing a fire by igniting flammable material.
  2. Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.
  3. Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  4. Do not damage the refrigerant circuit.
  5. Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
  6. The ambient temperature and humidity conditions of the cooler climate class following the tab below:
Test room

climate class

Dry bulb

temperature (⁰C)

Relative Humidity

(%)

Dew point (⁰C) Water vapor mass in

dry air (g/kg)

0 20 50 9.3 7.3
1 16 80 12.6 9.1
8 23.9 55 14.3 10.2
2 22 65 15.2 10.8
3 25 60 16.7 12.0
4 30 55 20.0 14.8
6 27 75 21.1 15.8
5 40 40 23.9 18.8
7 35 75 30.0 27.3
NOTE: the water vapor mass in dry air is one of the main points influencing the performance and energy consumption of the coolers. Therefore, the order of the climate class in the table is based on the water vapor mass column.

Warning: Risk of fire / flammable materials

Transportation and Placement

Transportation

  1. Take out packing and clean all the cabinet using warm water together with 5% of neutral soap then dry it with a soft-cloth; for the glass parts only use specific products, avoiding the use of water which can leave on the glass limestone residues.
  2. Keep a distance from the wall of 10 cm at least. Please level the unit by settling the adjustable feet.
  3. Cabinet must be installed on a perfectly even surface, far away from any heat source included sun ray.
  4. Do not install the unit in open places and do not expose it to rain.PREMIUM-LEVELLA-PRF65DX-Single-Door-Merchandiser-Refrigerator-fig-1

Choosing the installation location:
The unit is for indoor application only.
Due to the fact that the unit has a glass door, its performance is highly influenced by environmental conditions. To minimize the environmental effects on the unit’s performance, the following are recommended:

  • The unit is not to be placed near any kind of heat source
  • The unit is not to be placed near or inside air streams produced by ventilation fans, open doors and/ or windows
  • The unit is not to be situated under a roof-mounted ventilation system.
  • The unit should have sufficient space to ‘breathe’ (always use the rear space to ensure minimum clearance).
  • The unit should not be placed under direct sunlight.
  • Keep all ventilation openings in the appliance enclosure or in the structure clear of obstruction.
  • In order to reduce fire hazard, the installation of this appliance must be carried out only by a suitably qualified person.

Leveling the unit 

  • Place the unit at the chosen location. Using a spirit level, check whether the unit is levelled in both directions.
  • The spirit level can be placed on one of the shelves.
  • It is essential that the unit is levelled during operation so as to avoid possible ice formation on the evaporator’s fins due to insufficient drainage of the condensates.
  • Tilt unit by 2° angle for easy closing of door and drain.
  • Do not insert cream or spray bottles inside the cooler.
  • Do not store explosive substances such as aerosol cans with flammable propellant in the cooler.

Product Features

  1. It uses a quality, effective and hermetic compressor with broad range of starting voltage, suitable ambient temperature: not higher than 40℃, reasonable matching of the cooler system guarantees its powerful refrigerating ability and energy saving.
  2. Goods stored can be displayed clearly through the door made of luxurious hollow glass.
  3. The thermal insulation layer of the cooler made from hard polyurethane foamed plastics makes it be light and good ability to keep the contents cold.

Details of ProductPREMIUM-LEVELLA-PRF65DX-Single-Door-Merchandiser-Refrigerator-fig-2

Note Due to technological innovation, the descriptions of the product in this manual may not be completely consistent with your upright showcase. Details are in accordance with the material item. Production Dimension:

Model PRF65DX

PRF657DX

PRF90DX

PRF907DX

PRF125DX

PRF1257DX

PRF155DX

PRF1557DX

Dimension(W×D×H/mm) 575×540×1645 575×610×1710 615×610×1990 655×705×1990
Net Capacity(L) 189 239 339 439
Temperature(℃) 0~10 0~10 0~10 0~10
Control System Mechanical Mechanical Mechanical Mechanical
Lock & Light Yes Yes Yes Yes
Refrigerant R600a R290 R290 R290
Climate Type 3,4,5 3,4,5 3,4,5 3,4,5

Operation of the Temperature control knob

  1. The temperature inside the cabinet can be controlled with the temperature control knob.
  2. The knob should be kept upright normally to adjust the temperature.PREMIUM-LEVELLA-PRF65DX-Single-Door-Merchandiser-Refrigerator-fig-3
PREMIUM-LEVELLA-PRF65DX-Single-Door-Merchandiser-Refrigerator-fig-4 0 The product will cease to work
1 When the user does not need a colder temperature
2
3
4 When in normal use
5 When the user needs a colder

temperature

6 When the user needs a coldest

temperature

Note: The cooler should not work more than 24 hours in coldest function 6, please turn the knob back to 4 in time.

Electrical Connection

Electronic diagramPREMIUM-LEVELLA-PRF65DX-Single-Door-Merchandiser-Refrigerator-fig-5

WARNING

  1. Do not, under any circumstances, cut or remove the third ground prong from the power cord supplied.
    • This appliance is not designed to be used with an inverter.
    • The cord should be secured behind the appliance and not left exposed or dangling to prevent accidental injury.
  2. Never unplug the cooler by pulling the power cord. Always grip the plug firmly and pull straight out from the receptacle.
  3. Do not use an extension cord with this appliance. If the power cord is too short, have a qualified electrician or service technician install an outlet near the appliance. Use of an extension cord can negatively affect the performance of the unit.
  4. Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is damaged, have it replaced by an authorized service center.

Caution for Safety

  • Warning! Do not damage the cooling fluid circuit
  • Warning! Do not damage walls of the machine: the cooling fluid circuit may damage
  • Warning! Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
  • Warning! The equipment must not be used by persons (including children) whose physical, sensorial, or mental capacities are reduced, or who lack of experience and know-how, unless they have been provide, by means of a person responsible for their safety, with suitable monitoring or instructions about the use of the equipment. Children must be monitored to ensure they do not play with the equipment.

Caution for Using

  1. Unpack all packages before using the cooler. Don’t slant it over more than 60°, while moving it.
  2. When initial operation, the cooler should run emptily about two hours before storing food in it.
  3. The thermostat could adjust the temperature inside the cooler. When you turn the knob in clockwise, the bigger the figure, the lower the temperature. Generally, the position of ‘3-4’ is suitable.’6’position will be operating continually.
  4. To save energy, the door should not be frequently opened or left open for a long time.
  5. The surface and the inside of the cooler should be dry and clean. Long term moisture will cause the cooler rust slowly. (There will be some stains on the surface.)
  6. Periodical cleaning is suggested for your reference. Generally, 30-45 days once is the best. When cleaning, it is best to wipe the inside and the surface of the cooler with a soft cloth with neutral soap or detergent.

Caution: To ensure safety, the power plug must be pulled out before cleaning.

Cleaning of the unit

For cleaning the unit’s internal plastic parts, use a light solution of soap and water. Do not apply hard chemical detergents on the plastics as they may lose their brightness or even get deformed.
The same applies to the external metallic surfaces. The use of hard chemicals could harm the painting of the metallic surfaces, thus affecting the sanitary protection of the unit.

Ordinary Trouble and Remedies:
Please refer to the below trouble shooting lists to overcome any minor problems that occur during operations.

Trouble Reason Check Solution Remark
 

 

 

Lamp not lighting

 

 

No voltage

Fuse breaking off Check fuse Change fuse  

Ask a professional to maintain it.

Poor connection between the plug and

socket

The connection lease or not  

Repair or change the socket

 

Have voltage

lamp has poor contact

or worn down

Check the circuit and

lamp

Tighten the connection

or change a new lamp

 

 

 

 

 

 

Ask professional to maintain.

Lamp switch has poor

contact

Check the switch Tighten the connection

or change a new switch

 

 

 

 

Condenser fan

Not running

Compressor works

orderly

Condenser fan broken down  

Remove condenser fan

 

Change condenser fan

 

 

Compressor does not work

Thermostat is not set to the work position Check the position of the thermostat knob Revolve the thermostat knob to the operating

position

Thermostat terminal is not connected

properly

Check the thermostat terminal  

Reconnect the terminal

The thermostat is

worn down.

Check the thermostat Change the thermostat Ask professional to

maintain.

 

 

 

 

 

Continuous operating

 

 

Temperature is too high inside of the cabinet

Open the door too frequently  

/

Open the door as little as possible  

 

 

 

Ask professional to maintain.

 

Too much storage

The circulation of cooling air has been

affected

Take out part of the storage
Leakage of refrigerant. / Repair at a qualified

service center

Temperature is too low inside the

cabinet.

 

Thermostat does not work properly

 

Check the thermostat

 

Change the thermostat

Ask professional to maintain.
 

 

 

 

Noise

 

Cooler isn’t placed levelly

Check if the four wheels adjusted to the same level and

touching the ground

 

Adjust the wheels

 

Ask professional to maintain

Fixing screws of compressor or

condenser are loose

Screws fixed tightly or

not

Tighten the screws Ask professional to

maintain.

 

Compressor or fan defective

Check the Compressor or fan Ask help of professional to repair. Ask help of professional to

repair.

Condenser fan is working, but the   compressor doesn’t operate The plug of starter or heat relay is loose Check the starter and heat relay Install the starter or heat relay Ask a professional to maintain it.
 

Compressor defective

Check the resistance

of compressor CSM terminal

 

Change new compressor

Ask a professional to maintain it.
Voltage is lower than 97V or higher

than 130V

Check the input

Voltage

Use a voltage stabilizer
Evaporator fan

Not running

Fan switch defective Check the resistance

of switch

Change the switch  

Ask professional to maintain

Fan switch terminal is not connected properly Check the circuit of the fan switch Connect the switch terminal or change a

new terminal

Notice: The following are not trouble but common phenomenon:

  1. Sound, the refrigerant flows inside the cooler.
  2. The compressor and condenser become hot.
  3. If the ambient humidity is high, there may be dewdrops on the surface, please use soft and dry cloth to clean in time.

www.premiumlevella.com