We integrate.
You communicate.
K350
FIBER MASTER OTDR


Contents
Application scenarios

KL350 OTDR is widely used in optical network terminals (ONT), FTTH distribution (F2) fiber characterized distribution hubs (FDH), fault diagnosis and fault finding.
Product Features
- Long-haul network testing
- Access network testing
- FTTx/PON testing through splitters
- Compact, rugged, light weight 0.7kg
- All new UI design with innovation
- 32dB Dynamic range
- 1m Event dead zone
- Bult-in OPM、SLS、VFL、RJ45、FIP modules
- Link Map & Pass/Fail judgment functions
- Dual wavelengths testing

Multi-function

Dual Working Mode
Four test modes meet your measurement needs
Real-time test:
Monitors link measurement information, but does not analyze event information.
Average test:
Fixed time measurement, the results and event information will be analyzed after the measurement.
Intelligent automatic
It is convenient for beginners to quickly complete the test

Expert Manual Mode
Select the expert manual mode to test

Brand-new UI Design

Intelligent trace analysis
Intelligent trace analysis Dynamic display of test results
The test results are shown in a trace with distance on horizontal axis, lost power on vertical axis. When too many events, the horizontal and vertical axes can be enlarged to analyze.
Events List
Optical cable breakpoint, loss, length, bending, connection, etc., in the trace, the loss or reflection obtained by the test is represented by events, and three event parameters can be viewed at the same time.

Link Map

Splitter Test

Self Calibration
Self Calibration
Convenience to Maintenance
Circuit board
Optical circuit
Optical device

After the machine has been used for a long time, when its accuracy is not enough, it can perform self-calibration, reduce maintenance time and save costs
OTDR Trace Manager

Read and analyze on PC Mass Traces Operation
View the sor file in the OTDR trace manager, mass traces operation, add/delete events, bidirectional trace analysis, print preview, etc.
Fiber Connector

Standard Package

- Carry Bag
- OTDR main body
- Inspection Certificate
- Power adapter
- Gallus’s
- Quick Reference Guide
- Calibration Certificate
- Brochure-JILONG/TAWAA
Specifications
| ‘OTDR Specifications | |||
| Model | K350-S | K350-P | |
| Wavelength (nm) | SM 1310/1550 | PON 1310/1550/1625 (built-in filter) | |
| Dynamic range (dB) | 32/30 | 32/30/28 | |
| Number of optical port | 1 | 2 | |
| Applicable fiber | SM (ITU-T G.652) | ||
| Distance range (km) | 0.5,1,2,5,10,20,35,50,75,100,150,200 | ||
| Pulse width (ns) | 5,10,20,50,100,200,500,1000,2000,10000,20000 | ||
| Event dead zone*1 (m) | 1 | ||
| Attenuation dead zone*2 (m) | 4. | ||
| Number of sampling points | Max.80000 _ |
||
| Sampling resolution | Min.0.04m | ||
| Distance measurement accuracy | ±(0.75 m + Measurement distance x 2 x 10-5 + Sampling resolution) | ||
| measurement accuracy _Loss |
±0.03 dB/dB | ||
| Return loss measurement accuracy | ±2 dB | ||
| Optical Power Meter Module (Built-in) | ✔ | x | |
|
OPM
. |
Wavelength (nm) | 800 – 1650nm | |
| Power range | -70 – +6dBm | ||
| Measure accuracy | < (±0.2dB or ±5%) | ||
| Display resolution | 0.01dB | ||
| Optical input port | SC/UPC + 2.5mm Universal ferrule | ||
| Stabilized Light Source Module (Built-in) | ✔ | ✔ | |
| SLS
|
Wavelength (nm) | 1310/1550 | |
| Output power | ≥-10dBm | ||
| Modulation mode | CW, 270 Hz, 1 kHz, 2 kHz | ||
| Laser class | Class 1M or Class 1 | ||
| Optical input port | OTDR port | ||
| ‘Visual Fault Locator Module (Built-in) | ✔ | ✔ | |
|
VFL |
Wavelength (nm) | 650 | |
| Output power | 10mW | ||
| Modulation mode | CW, CHOP (2 Hz) | ||
| Laser class | Class 3R | ||
| Optical input port | 2.5 mm Universal ferrule type | ||
| Fiber Inspection Probe (Built-in) Optional | Optional | Optional | |
|
FIP
|
Magnification | 250X | |
| Resolution(um) | ≥-1.0 | ||
| Electrical interface | USB2.0 | ||
| Optical Connector | FC/UPC,SC/UPC,ST/UPC | ||
| Sensor | 1/3 inch | ||
| ✔ | ✔ | ||
|
RJ45
|
Wavelength (nm) | CAT5, CAT6 | |
| Distance of Cable Collation! | 300m | ||
| Distance of emitting signal | 300m | ||
| General Specifications | |
| Link Map | ✔ |
| Pass/Fail judgment | ✔ |
| Distance unit | m, km, mile, ft, kit |
| PC Analysis Software | ✔ |
| Languages | English, Espanola, Chinese, Portuguese, Francis, PyCCRL41 |
| Optical connector | SC/UPC (FC/UPC,ST/UPC,LC/UP is Optional) |
| Display | 3.5-inch color TFT LCD (Resolution: 640 x 480) |
| Electrical interface | Charge port x 1, USB 2.0 x 3, RJ45 x 2 |
| Operating temperature | -10 – 50°C (0 – 40°C when AC adapter is being used. 0 to 35°C when battery is be charged) |
| Storage temperature | -20 to 60°C |
| Altitude | 4000 m |
| Humidity | 0 to 90% RH (20 to 90% with 739874 AC adapter, non-condensing) |
| Power requirements | 100 – 240V AC, 50/60Hz (AC adapter) |
| Battery | 3000mAh |
| LED Light illumination | ≥15000mcd |
| Operating time*3 | 5 hours |
| Data storage | Internal storage: ≥1000 waveforms, External storage: USB memory |
| Dimensions | 118 mm (W) x 218 mm (H) x 55 mm (D) |
| Weight | Approx. 0.73 kg (including internal battery and protectors, excluding OTDR unit and options) |
Notes:
- Minimum pulse width, return loss: ≥55 dB (≥40 dB for 850/1300 nm), group refractive index: 1.5, at 1.5 dB below the unsaturated peak level.
- Minimum pulse width, group refractive index: 1.5, at a point where the backscatter level is within ±0.5dB of the normal level. For SMF, at 1310nm, return loss: ≥55dB.
- New Battery
All specifications valid at 23°C ± 2°C (73.4°F ± 3.6°F) unless otherwise specified.