WARNING
To avoid serious product damage or personal injury, do not use this device in an overhead suspension application.

NOTE: Enclosure stiffening brackets may be required in some applications. Contact your local Hoffman Sales Representative for more information.

ASWV88

With rotation limiting screw and the mark on the base aligned, turn the limiting screw clockwise until it bottoms. Turn the limiting screw back counter—clockwise the number of turns
associated with the desired rotation shown to the right. If the rotation limiting screw is removed, the rotation is limited to 350°.

ANGLE DEGREES/TURNS
1 60° bottom
2 90° 1.5 turns (counter-clockwise)
3 120° 3 turns (counter-clockwise)
4 150° 4.5 turns (counter-clockwise)
5 350° 7.5 turns (counter-clockwise)

4×4 Mounting patterns