NOTE TO USERS
NI 66xx Pinout Labels for the
SCB-68
Instruction Manual
NI 66xx Pinout Labels for the SCB-68
Counter/Timer Modules/Devices Using the 68-Pin Shielded Connector Block
If you are using an NI 66xx (formerly referred to as TIO) counter/timer device or module with the SCB-68, you can print and attach a connector-specific pinout label to the cover of the connector block for easy connection reference. This document provides labels for the following models:
- NI 6601
- NI 6602
- NI 6608
- NI 6612
- NI 6614
Use the following label if you are connecting the SCB-68 to NI 6601, NI 6602, and NI 6608 models.
SCB-68 Quick Reference Label
NI 660x Counter/Timer (TIO) Models
DIO/CTR | DIO/CTR | DIO/CTR |
68 D GND 34 PFI 31/P0.31/CTR 2 SOURCE 67 PFI 30/P0.30/CTR 2 GATE 33 D GND 66 PFI 29/P0.29/CTR 2 AUX 32 PFI 28/P0.28/CTR 2 OUT 65 D GND 31 PFI 27/P0.27/CTR 3 SOURCE 64 PFI 26/P0.26/CTR 3 GATE 30 D GND 63 PFI 25/P0.25/CTR 3 AUX 29 PFI 24/P0.24/CTR 3 OUT 62 D GND 28 PFI 23/P0.23/CTR 4 SOURCE 61 PFI 22/P0.22/CTR 4 GATE 27 D GND 60 PFI 21/P0.21/CTR 4 AUX 26 PFI 20/P0.20/CTR 4 OUT 59 D GND 25 PFI 19/P0.19/CTR 5 SOURCE 58 PFI 18/P0.18/CTR 5 GATE 24 D GND 57 PFI 17/P0.17/CTR 5 AUX 23 PFI 16/P0.16/CTR 5 OUT |
12 PFI 3/P0.3 46 D GND 13 PFI 4/P0.4 47 PFI 5/P0.5 14 D GND 48 PFI 6/P0.6 15 PFI 7/P0.7 49 D GND 16 PFI 8/P0.8/CTR 7 OUT 50 D GND 17 PFI 9/P0.9/CTR 7 AUX 51 PFI 10/PO.10/CTR 7 GATE 18 D GND 52 PFI 11/P0.11/CTR 7 SOURCE 19 R GND 53 PFI 12/PO.12/CTR 6 OUT 20 D GND 54 PFI 13/P0.13/CTR 6 AUX 21 PFI 14/P0.14/CTR 6 GATE 55 D GND 22 PFI 15/P0.15/CTR 6 SOURCE 56 R GND |
1 +5 V 35 R GND 2 PFI 39/CTR 0 SOURCE 36 D GND 3 PFI 38/CTR 0 GATE 37 RESERVED 4 RESERVED 38 RESERVED 5 PFI 36/CTR 0 OUT 39 D GND 6 PFI 33/CTR 1 AUX 40 PFI 37/CTR 0 AUX 7 PFI 35/CTR 1 SOURCE 41 D GND 8 PFI 34/CTR 1 GATE 42 D GND 9 PFI 32/CTR 1 OUT 43 R GND 10 PFI 0/P0.0 44 PFI 1/P0.1 11 D GND 45 PFI 2/P0.2 |
R GND: These terminals are routed to RESERVED when using the product with a SH68-68-D1 shielded cable or routed to D GND when using the product with a R68-68 ribbon cable.
Use the following label if you are connecting the SCB-68 to NI 6612 and NI 6614 models.
Figure 2. NI 661x
SCB-68 Quick Reference Label
NI 661x Counter/Timer (TIO) Models
DIO/CTR | DIO/CTR | DIO/CTR |
68 D GND 34 PFI 31/P0.31/CTR 2 SOURCE 67 PFI 30/P0.30/CTR 2 GATE 33 D GND 66 PFI 29/P0.29/CTR 2 AUX 32 PFI 28/P0.28/CTR 2 OUT 65 D GND 31 PFI 27/P0.27/CTR 3 SOURCE 64 PFI 26/P0.26/CTR 3 GATE 30 D GND 63 PFI 25/P0.25/CTR 3 AUX 29 PFI 24/P0.24/CTR 3 OUT 62 D GND 28 PFI 23/P0.23/CTR 4 SOURCE 61 PFI 22/P0.22/CTR 4 GATE 27 D GND 60 PFI 21/P0.21/CTR 4 AUX 26 PFI 20/P0.20/CTR 4 OUT 59 D GND 25 PFI 19/P0.19/CTR 5 SOURCE 58 PFI 18/P0.18/CTR 5 GATE 24 D GND 57 PFI 17/P0.17/CTR 5 AUX 23 PFI 16/P0.16/CTR 5 OUT |
12 PFI 3/P0.3 46 D GND 13 PFI 4/P0.4 47 PFI 5/P0.5 14 D GND 48 PFI 6/P0.6 15 PFI 7/P0.7 49 D GND 16 PFI 8/P0.8/CTR 7 OUT 50 D GND 17 PFI 9/P0.9/CTR 7 AUX 51 PFI 10/PO.10/CTR 7 GATE 18 D GND 52 PFI 11/P0.11/CTR 7 SOURCE 19 R GND 53 PFI 12/PO.12/CTR 6 OUT 20 D GND 54 PFI 13/P0.13/CTR 6 AUX 21 PFI 14/P0.14/CTR 6 GATE 55 D GND 22 PFI 15/P0.15/CTR 6 SOURCE 56 R GND |
1 +5 V 35 R GND 2 PFI 39/P1.7/CTR 0 SOURCE 36 D GND 3 PFI 38/P1.6/CTR 0 GATE 37 RESERVED 4 RESERVED 38 RESERVED 5 PFI 36/P1.4/CTR 0 OUT 39 D GND 6 PFI 33/P1.1/CTR 1 AUX 40 PFI 37/P1.6/CTR 0 AUX 7 PFI 35/P1.3/CTR 1 SOURCE 41 D GND 8 PFI 34/P1.2/CTR 1 GATE 42 D GND 9 PFI 32/P1.0/CTR 1 OUT 43 R GND 10 PFI 0/P0.0 44 PFI 1/P0.1 11 D GND 45 PFI 2/P0.2 |
R GND: These terminals are routed to RESERVED when using the product with a SH68-68-D1 shielded cable or routed to D GND when using the product with a R68-68 ribbon cable.
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.
COMPREHENSIVE SERVICES
We offer cdmpetitive repair and calibration services, as well as easily accessible documentation and free downloadable resources.
SELL YOU SUPLUS
We buy new, used, decommissioned, and surplus parts from every NI series.
We work out the best solution to suit your individual needs.
Sell For Cash
Get Credit
Receive a Trade-In Deal
OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP
We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.
Bridging the gap between the manufacturer and your legacy test system.
1-800-915-6216
www.apexwaves.com
[email protected]
Alltrademarks,brands, and brand names are theproperty of their espective owners:
Request a Quote CLICK HERE PCle-6612
© 2018 National Instruments. All rights reserved.