Morningstar SS-MPPT-15L SunSaver Professional Series User Guide

Home » Morningstar » Morningstar SS-MPPT-15L SunSaver Professional Series User Guide

Morningstar - logoSS-MPPT-15L Sun Saver Professional Series
User Guide

SS-MPPT-15L Sun Saver Professional Series

Morningstar SS-MPPT-15L SunSaver Professional Series - icon

Scan QR Code to go directly to the Sun Saver MPPT Installation Manual and warranty information online.

Morningstar SS-MPPT-15L SunSaver Professional Series - qr codehttps://www.morningstarcorp.com/wp-content/uploads/2014/2014/02/SSMPPT.IOM_.EN_.03-4-131.pdfMorningstar SS-MPPT-15L SunSaver Professional Series - iconWarranty Registration: https://www.morningstarcorp.com/product‐registration/ 

Safety Information

WARNING: Shock Hazard
The Sun Saver MPPT controller must be installed by a qualified technician in accordance with the electrical  regulations of the country of installation.
WARNING: Shock Hazard
This unit is not provided with a GFDI device.  This charge  controller must be used with an external GFDI device as  required by the Article 690 of the National Electrical Code  for the installation location.
IMPORTANT:  READ the  Sun Saver  MPPT Installation  Manual for  safety and  regulatory information,  instructions on configuration and  operation, and   warranty  information.
In the Box:Morningstar SS-MPPT-15L SunSaver Professional Series - BoxTools Required:
Morningstar SS-MPPT-15L SunSaver Professional Series - icon 1 —  #2 Philips Screwdriver
Morningstar SS-MPPT-15L SunSaver Professional Series - icon 2 —  3/16  (5 mm) & 3/32″ (2.5 mm) Flathead Screwdriver
—  Drill with a 3/32″ (2.5 mm) bit
—  MultimeterMorningstar SS-MPPT-15L SunSaver Professional Series - Tools

Optional Accessories

Morningstar SS-MPPT-15L SunSaver Professional Series - Optional Accessories

SunSaver MPPT™ Charge Controller

Minimum Clearance Requirements:Morningstar SS-MPPT-15L SunSaver Professional Series - Minimum WARNING: Explosion Hazard
Never  install the  Sun Saver  MPPT in an  enclosure with  vented/flooded  batteries.   Battery fumes are  flammable   and will corrode  and destroy the Sun Saver  circuits.
WARNING: Risk of Fire
If a  Remote  Temperature  Sensor  (RTS) is NOT  connected,   locate  the Sun Saver  MPPT within  3 m  (10 ft)  of the  batteries.    Internal  temperature compensation  will be  used if the  RTS  is  not  connected.   Use  of  the RTS is  strongly recommended.
CAUTION: Equipment Damage
Do not expose the Sun Saver MPPT to weather.  Locate in a dry,  protected area to prevent equipment damage.  Ensure the  minimum clearance requirements are followed to provide   equate ventilation and prevent the unit from overheating.

Mounting

Step 1: Choose Mounting Location
Locate the Sun Saver MPPT on a vertical surface  protected from direct sun, high temperatures, and water.
Step 2: Check for Clearance and Ventilation
Place the Sun Saver MPPT in the location where it will be  mounted. Verify that there is sufficient room to run wires  and that there is ample room above and below the  controller for air flow.Morningstar SS-MPPT-15L SunSaver Professional Series - Mounting LocationStep 3: Mark Holes
Use a pencil or pen to mark the four (4)  mounting hole locations on the mounting surface.
Step 4: Drill Holes
Remove the controller and drill 3/32” (2.5 mm)  holes in the marked locations.
Step 5: Secure Controller
Place the controller on the surface and align the mounting  holes with the drilled holes in step 4.  Secure the controller  in place using the Mounting screws (included).Morningstar SS-MPPT-15L SunSaver Professional Series - Mounting Location 1Photovoltaic (PV) Array
See the Morningstar PV String Calculator at: https://string‐calculator.morningstarcorp.com/Morningstar SS-MPPT-15L SunSaver Professional Series - Charge Controller IMPORTANT:
Array Voltage should NEVER exceed  the maximum input voltage.
STATUS LED

Color Indication Operating State
NoneMorningstar SS-MPPT-15L SunSaver Professional Series - icon OFF (with heartbeat¹) Night
Green Morningstar SS-MPPT-15L SunSaver Professional Series - icon 1 ON Solid (with heartbeat²) Charging
Red Morningstar SS-MPPT-15L SunSaver Professional Series - icon 32 Flashing Error
Red Morningstar SS-MPPT-15L SunSaver Professional Series - icon 32 ON Solid (with heartbeat²) Critical Error

¹ heartbeat indication flickers the Status LED ON briefly every 5 seconds
²heartbeat indication flickers the Status LED OFF briefly every 5 seconds

Recommended Order of
Installation
Wiring and Torque Requirements
Component Wire Size (Solid) Wire Size (multistring) Wire Size (fine strand) Torque (Maximum) Tool Required
1 Load Terminals #6 AWG 16 mm2
(Maximum)
#6 AWG 16 mm2
(Maximum)
#8 AWG 10 mm2
(Maximum)
10.6 in-lbs.
(1.2 Nm)
3/1615 mm) Morningstar SS-MPPT-15L SunSaver Professional Series - icon 4 Flathead Screwdriver
2 Battery Terminals
3 Solar Terminals
4 Remote Temperature
Sensor
#22 AWG / 0.3 mm2 (Minimum)
#12 AWG / 3.0 mm2 (Maximum)
3.5 in-lbs.
(0.4 Nm)
3/32″ (2.5 mm) Morningstar SS-MPPT-15L SunSaver Professional Series - icon 4 Flathead Screwdriver
5 Fuses or Disconnects *Fuse or breaker sizing must be based on required wire ampacity.
If using a fuse, do NOT insert the fuse in the fuse-holder until after all the other connections have been completed.

IMPORTANT:  Example only.  Actual wiring may vary.  READ  the Sun Saver   MPPT  Installation, Operations,  and Maintenance  Manual  for  mandatory   safety requirements.   All configuration must comply with local and national  electric codes.  Consult your local electric authority to ensure compliance.

BATTERY STATE-OF-CHARGE (SOC) LEDs
SOC LED Indication Battery Status Load Status
GreenMorningstar SS-MPPT-15L SunSaver Professional Series - icon 1 Fast Flashing (2 Flash / sec) Equalize Charge Load ON
GreenMorningstar SS-MPPT-15L SunSaver Professional Series - icon 1 Medium Flashing (1 Flash / sec) Absorption Charge Load ON
GreenMorningstar SS-MPPT-15L SunSaver Professional Series - icon 1 Slow Flashing (1 Flash / 2 sec) Float Charge Load ON
GreenMorningstar SS-MPPT-15L SunSaver Professional Series - icon 1 ON Solid Nearly Full Load ON
Yellow Morningstar SS-MPPT-15L SunSaver Professional Series - icon 5 ON Solid Half Full Load ON
Red Morningstar SS-MPPT-15L SunSaver Professional Series - icon 32 Flashing (1 Flash / sec) Battery Low LVD Warning (Load On)
RedMorningstar SS-MPPT-15L SunSaver Professional Series - icon 32 ON Solid Battery Empty LVD (Load Off)

WARNING: Shock Hazard
Test  between all terminals and  ground  before  touching.
Power or accessory terminals are NOT electrically isolated from DC input and may be energized with hazardous solar voltage.
WARNING: Shock Hazard
Fuses, circuit breakers, and disconnect switches never open grounded system conductors. Only GFDI devices are permitted to disconnect grounded conductors.
IMPORTANT:
Ensure there is only 1 DC Negative‐to‐Ground Bond in the entire system.Morningstar SS-MPPT-15L SunSaver Professional Series - icon 6

Power UP Sequence:

  1. Connect Battery/Battery  Bank.
  2. Connect Solar.

Power DOWN Sequence:

  1. Disconnect Solar.
  2. Disconnect Battery/Battery  Bank.

Specifications:

SS-MPPT-15L
Nominal Battery Voltage 12 V or 24 V
Max. Solar Input Voltage 60 V
Nominal Maximum Input Power 200 W / 400 W
Maximum Battery Current 15 A
Battery Voltage Range 7 – 36 V
Rated Load Current 15 A

Operational Configuration:

Morningstar SS-MPPT-15L SunSaver Professional Series - Operational Configuration

  1. Set points for this switch setting can be modified with custom programming.

Contact Information:
Technical Support:  Support.morningstarcorp.com
Phone: 1‐215‐321‐4457

BATTERY SET POINTS
12-volt (24-volt)
Set Point GEL Sealed AGM Flooded
Absorption Voltage 14.0 V
(28.0 V)
14.1 V
(28.2 V)
14.3 V
(28.6 V)
14.4 V
(28.8 V)
Float Voltage 13.7 V
(27.4 V)
13.7 V
(27.4 V)
13.7 V
(27.4 V)
13.7 V
(27.4)
Time until Float 3 hours 3 hours 3 hours 3 hours
Equalize Voltage N/A N/A 14.5 V 14.9 V
Equalize Duration N/A N/A 3 hours 3 hours
Equalize Calendar (days) N/A N/A 28 28
Maximum Regulation Voltage* 15 V (30 V)
LVD**/ LVR** (Switch 2 OFF) 11.5 V /12.6 V @ 12 V (23.0 V/25.2 V @ 24 V)
LVD**/LVR** (Switch 2 ON) 11.0 V/12.1 V @ 12 V (22.0 V/24.2 V @ 24 V)
Load HVD** 15.3 V (30.6 V)
Load HVR** 14.5 V (29 V)
Array HVID (Temp. Comp.) Highest voltage set point + 0.5 V
Array HVR (Temp. Comp.) 13.8 V (27.6 V)
Not temperature compensated. 15 V @ 12 V nominal, 30 V @ 24 V nominal.
** Adjustable by DIP Switch 2. Not temperature compensated. Can be modified in custom settings.

1 For Custom Programming:
Use the software available at https://www.morningstarcorp.com/msview/.
See the Sun Saver MPPT Installation, Operations, and Maintenance Manual for additional information/guidance.
Switch 2: Load Control /
Low Voltage Disconnect/ReconnectsMorningstar SS-MPPT-15L SunSaver Professional Series - Load ControlSwitch 3: Auto-Equalization

Morningstar SS-MPPT-15L SunSaver Professional Series - Auto-Equalization

Switch 4: Communication Mode -Meter/MODBUS® Morningstar SS-MPPT-15L SunSaver Professional Series - Meter

Remote Meter, & Relay Driver
MODBUS®  Protocol for  MS View, Ethernet Meter bus  Converter, 3 rd. ‐Party Devices

Morningstar - logo© 2021 Morningstar Corporation.
All Rights Reserved.
MS‐003294 SS‐MPPT