MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter Owner’s Manual

Home » Mitsubishi Heavy » MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter Owner’s Manual

MITSUBISHI HEAVY logoEXTERIOR DIMENSIONS
Models SRK10YL-S, 13YL-S, 18YL-S

Indoor units

MITSUBISHI HEAVY SRK10YL-S Air Conditioner InverterSpace for installation and service when viewing from the front

Symbol Content
A Gas piping Model 10,13 09.52 (3/8″) (Flare)
Model 18 0 12.7 (1/2″) (Flare)
B Liquid piping 06.35 (1/4″) (Flare)
C Hole on wall for right rear piping (65)
D Hole on wall for left rear piping (65)
E Drain hose VP16
F Outlet for wiring
G Outlet for piping (on both side)

Wireless remote control

MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure 1

Note 1The model name label is attached on the underside of the panel.

Outdoor units

Models SRC10YL-S, 13YL-S

MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure 2MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure 3

Notes

  1. It must not be surrounded by walls on the four sides.
  2. The unit must be fixed with anchor bolts. An anchor bolt must not protrude more the 15mm.
  3. Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction.
  4. Leave 1m or more space above the unit.
  5. A wall in front of the blower outlet must not exceed the units height.
  6. The model name label is attached on the lower right comer of the front panel.

MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure 4

Note(1) If the wall is higher than 1.2 m or a ceiling is present, distances larger than indicated in the above table must be provided.

Symbol Content
A Service valve connection (gas side) (1) 9.52 (3/8′) (Flare)
B Service valve connection (liquid side) X6.35 (1/4′) (Flare)
C Pipe/cable draw-out hole
D Drain discharge hole 0 20 x 2 places
E Anchor bolt hole M10 x 4 places

Models SRC18YL-S

MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure 5MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure 6

Notes

  1. It must not be surrounded by walls on the four sides.
  2. The unit must be fixed with anchor bolts. An anchor bolt must not protrude more than 15mm.
  3. Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction.
  4. Leave 1m or more space above the unit.
  5. A wall in front of the blower outlet must not exceed the units height.
  6. The model name label is attached on the lower right corner of the front panel.

MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure 7

Note(1) If the wall is higher than 1.2 m or a ceiling is present, distances larger than indicated in the above table must be provided.

Symbol Content
A Service valve connection (igas side) 0 12.7 (1/2″) (Flare)
B Service valve connection (iliquid side) 0 6.35 (1/4′) (Flare)
C Pipe/cable draw-out hole
D Drain discharge hole 0 20 x 2 places
E Anchor bolt hole M10 x 4 places