EXTERIOR DIMENSIONS
Models SRK10YL-S, 13YL-S, 18YL-S
Contents
Indoor units
Space for installation and service when viewing from the front
| Symbol | Content | |
| A | Gas piping | Model 10,13 09.52 (3/8″) (Flare) |
| Model 18 0 12.7 (1/2″) (Flare) | ||
| B | Liquid piping | 06.35 (1/4″) (Flare) |
| C | Hole on wall for right rear piping | (65) |
| D | Hole on wall for left rear piping | (65) |
| E | Drain hose | VP16 |
| F | Outlet for wiring | |
| G | Outlet for piping (on both side) | |
Wireless remote control

Note 1The model name label is attached on the underside of the panel.
Outdoor units
Models SRC10YL-S, 13YL-S


Notes
- It must not be surrounded by walls on the four sides.
- The unit must be fixed with anchor bolts. An anchor bolt must not protrude more the 15mm.
- Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction.
- Leave 1m or more space above the unit.
- A wall in front of the blower outlet must not exceed the units height.
- The model name label is attached on the lower right comer of the front panel.

Note(1) If the wall is higher than 1.2 m or a ceiling is present, distances larger than indicated in the above table must be provided.
| Symbol | Content | |
| A | Service valve connection (gas side) | (1) 9.52 (3/8′) (Flare) |
| B | Service valve connection (liquid side) | X6.35 (1/4′) (Flare) |
| C | Pipe/cable draw-out hole | |
| D | Drain discharge hole | 0 20 x 2 places |
| E | Anchor bolt hole | M10 x 4 places |
Models SRC18YL-S


Notes
- It must not be surrounded by walls on the four sides.
- The unit must be fixed with anchor bolts. An anchor bolt must not protrude more than 15mm.
- Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction.
- Leave 1m or more space above the unit.
- A wall in front of the blower outlet must not exceed the units height.
- The model name label is attached on the lower right corner of the front panel.

Note(1) If the wall is higher than 1.2 m or a ceiling is present, distances larger than indicated in the above table must be provided.
| Symbol | Content | |
| A | Service valve connection (igas side) | 0 12.7 (1/2″) (Flare) |
| B | Service valve connection (iliquid side) | 0 6.35 (1/4′) (Flare) |
| C | Pipe/cable draw-out hole | |
| D | Drain discharge hole | 0 20 x 2 places |
| E | Anchor bolt hole | M10 x 4 places |