Contents
MEAN WELL MDR-60-24 60W Single Output Industrial DIN Rail Power Supply
Product Information
Specifications:
- Product Name: 60W Single Output Industrial DIN Rail Power Supply
- Series: MDR-60
- GTIN CODE: [Insert GTIN CODE]
- Features:
- Universal AC input/Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Class I, Div 2 Hazardous Locations T4
- LED indicator for power on
- DC OK relay contact
- No load power consumption
Product Usage Instructions
Installation:
- Ensure the power supply is compatible with your system’s requirements.
- Mount the power supply on a DIN rail TS-35/7.5 or 15 securely.
- Connect the universal AC input to the power source.
- Verify proper cooling by allowing free air convection around the power supply.
Operation:
- Check the LED indicator for power status.
- Ensure proper connections for DC output.
- Monitor for any overload or short circuit issues.
Maintenance:
- Regularly check for dust accumulation and clean if necessary.
- Inspect for any signs of wear or damage and replace components as needed.
FAQ
- Q: What should I do if the DC OK relay contact is not functioning?
A: Check the connections and ensure they are properly secured. If the issue persists, contact customer support for assistance. - Q: Can the power supply be used in hazardous locations other than Class I, Div 2 areas?
A: No, it is recommended to only use the power supply in Class I, Div 2 Hazardous Locations T4 as specified.
60W Single Output Industrial DIN Rail Power Supply
MDR-60 series
Features
- Universal AC input/Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Class I, Div 2 Hazardous Locations T4
- LED indicator for power on
- DC OK relay contact
- No load power consumption<0.75W
- 100% full load burn-in test
- 3 years warranty
GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx
MODEL | MDR-60-5 | MDR-60-12 | MDR-60-24 | MDR-60-48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 24V | 48V |
RATED CURRENT | 10A | 5A | 2.5A | 1.25A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1.25A | |
RATED POWER | 50W | 60W | 60W | 60W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 5 ~ 6V | 12 ~ 15V | 24 ~ 30V | 48 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.5% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME Note.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 50ms/230VAC 20ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 78% | 85% | 87% | 87% | |
AC CURRENT (Typ.) | 1.8A/115VAC 1A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC 60A/230VAC | ||||
LEAKAGE CURRENT | <1mA / 240VAC | ||||
PROTECTION |
OVERLOAD | 105 ~ 150% rated output power | |||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | 6.25 ~ 7.25V | 15.6 ~ 18V | 31.2 ~ 36V | 57.6 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||
FUNCTION | DC OK SIGNAL | Relay contact rating(max.): 30V/1A resistive | |||
ENVIRONMENT | WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||
VIBRATION | Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 | ||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Ul508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 , IS13252(Part1)/IEC60950-1(except 48V) approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B | ||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EAC TP TC 020 | ||||
OTHERS |
MTBF | 2355.2K hrs min. Telcordia SR-332 (Bellcore) ; 489.9K hrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 40*90*100mm (W*H*D) | ||||
PACKING | 0.33Kg; 42pcs/14.8Kg/0.82CUFT | ||||
NOTE |
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
Block Diagram
Contact Close | PSU turns on / DC OK. |
Contact Open | PSU turns off / DC Fail. |
Contact Ratings (max.) | 30V/1A resistive load. |
- Derating Curve
- Output Derating VS Input Voltage
- Downloaded from Arrow.com.
- File Name: MDR-60-SPEC 2024-02-19