MAYTAG MG2R Gas Furnace
Contents
For 80+ and 90+ Single Stage Furnaces
Refer to the Installation Instructions provided with the furnace for the proper heating and cooling speeds for your application.
Red LED Flash | Error/Condition |
Flash codes stored in memory (auto-erased after 14 days) | |
1 | System Lockout (Retries Exceeded) |
2 | Pressure Switch Stuck Closed |
3 | Pressure Switch Stuck Open |
4 | Open High Temperature Limit Switch |
5 | Flame Sensed>4.25 Seconds with Gas Valve De-Energized |
6 | Open Flame RO Switch |
8 | Ignitor Relay Error |
10 | Open Fuse |
11 | Ignitor Open |
12 | Inducer Relay Error |
Flash codes NOT stored in memory | |
7 | Low Flame Sense Signal |
9 | Twinning Fault |
Off | Control Failure / No Power / Internal Fault / IRQ Loss |
Gas Heating Lockout (Gas valve energized when it should be de-energized) | |
Or Gas valve De-energized when it should be Energized | |
Rapid Flash | Reverse Polarity |
Continuous On | Normal Operation |
If any of the original wire as supplied with the furnace must be replaced, it must be replaced with wiring material having a temperature of at least 105 C.
Use copper conductors only.
Cool Motor SPEED DIPSWITCH SETTING (S1-1, S1-2, S1-3) | |||||||||||||||||||||||||
1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | ||
Position | OFF OFF OFF | ON OFF OFF | ON ON OFF | OFF ON OFF | OFF OFF ON | OFF ON ON | ON OFF ON | ON ON ON | |||||||||||||||||
Motor SPEED Cool | Y | T1 | T2 | T3 | T4 | T1+T2 | T1 | T1 | T1 |
Heat Motor SPEED DIPSWITCH SETTING (S2-1, S2-2) | |||||||||
1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | ||
Position | OFF OFF | ON OFF | ON ON | OFF ON | |||||
Motor SPEED Heat | W | T1 | T2 | T3 | T4 |
Fan Motor SPEED DIPSWITCH SETTING (S2-3, S2-4) | |||||||||
1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | ||
Position | OFF OFF | ON OFF | OFF ON | ON | ON | ||||
Motor SPEED Fan | G | T1 | T2 | T4 | T1+T2 |
WIRING DIAGRAM