HRST-ANF HomeWorks Fan Control

Specifications:

  • Product Name: HomeWorks Fan Control
  • Model: HRST-ANF
  • Input Voltage: 120 V~
  • Frequency: 50/60 Hz
  • Current: 1.5 A
  • Compatible with AC fan only
  • Part Number: 043595 Rev. A

Product Usage Instructions:

1. Install the Fan:

Follow the manufacturer’s instructions to correctly install the
fan and ensure proper operation.

2. Set the Fan Speed:

Use the pull chains to set the fan to the highest speed before
proceeding with the installation.

3. Turn Power Off:

Before starting the installation process, ensure to turn off the
power at the circuit breaker to prevent any electrical hazards.

4. Remove Existing Switch:

Remove the existing switch from the wall by detaching the
wallplate from the switch.

5. Connect the Fan Control:

  1. Connect the bare copper or green ground wire from the wallbox
    to the green wire on the fan control using a wire connector.
  2. Connect the neutral wire from the wallbox to the white wire on
    the fan control using a wire connector.
  3. Connect the load/tagged wire from the wallbox to the yellow
    wire on the fan control using a wire connector.

6. Mount the Fan Control:

Securely mount the fan control according to the provided
instructions.

7. Turn Power On:

After completing the installation, turn on the power at the
circuit breaker to activate the fan control.

8. Set-Up with System:

Operate the fan control by adjusting between the 4 speeds: High,
Medium-High, Medium, and Low. Use the FASS switch for
front-accessible service.

FAQ:

Q: Can I use this fan control with DC motor fans?

A: No, this fan control is designed for use with AC fans only.
Do not use it with DC motor fans.

Q: Can I control lighting loads using this fan control?

A: No, do not use this fan control to control lighting loads on
a fan or connect it to any lighting load type.

Installing your fan control

Fan Control
Please read before installing
HomeWorks Fan Control
HRST-ANF, 120 V~ 50 / 60 Hz 1.5 A
AC fan only

P/N 043595 Rev. A
English

IMPORTANT NOTES 1. For indoor use only. 2. Operate between 32 °F (0 °C) and 104 °F (40 °C). 3. Use to control one paddle-type ceiling fan. 4. Use the ceiling fan’s pull chain to set its speed to
the highest setting. 5. Do not use to control exhaust fans (e.g. bathroom
or kitchen exhaust fans). 6. Do not use to control fans that have integrated fan
speed controls other than a pull chain (i.e. fans that have a remote control), unless the integrated control is removed from the ceiling fan. 7. Do not connect to any other motor-operated appliance or to any lighting load type. 8. Do not use to control lighting loads on a fan. 9. Do not use to control DC motor fans.
Help
Use our mobile friendly self-paced installation tool: www.lutron.com/wiringwizard
Find more product information: www.lutron.com/support
– Videos – Frequently Asked Questions Call us: U.S.A. | Canada | Caribbean 1.844.LUTRON1 (588.7661) (24/7) Mexico +1.888.235.2910 Others +1.610.282.3800
www.lutron.com/support
This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna · Increase the separation between the equipment and receiver · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected · Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment. The user should avoid prolonged exposure within 7.9 in (20 cm) of the antenna, which may exceed FCC/ISED radio frequency exposure limits. This Class B digital apparatus complies with Canadian ICES-003. Lutron, the Starburst Logo, FASS and Sunnata are are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. All other product names, logos, and brands are property of their respective owners. © 2024 Lutron Electronics Co., Inc

1 Install the fan
Install the fan according to the manufacturer’s instructions and ensure proper operation.

4 Remove existing switch from wall
Remove the wallplate from the switch.

2 Set the fan speed
Set the fan to the highest speed using the pull chains.
3 Turn power off at circuit breaker!

1 2 Remove the switch and pull it away from the wall.

ON ON OFF OFF

3

WARNING: SHOCK HAZARD. May result in serious injury or death. Turn off power at circuit breaker or fuse before installing.

4 Place tag on load wire. Disconnect all three wires* from the switch.
5
6 Tag

Ground 7

Tag

5 Load Ratings (if ganging devices)

Maximum Allowable Wattage

Single Gang

End of Gang

Middle of Gang

FAN

1.5 A

1.5 A

1.5 A

6 Connect the fan control
4
Tag 3
2 1 Ground
1 Connect the bare copper (or green) “ground” wire from the wallbox to the green wire on the fan control using a wire connector.
2 Wrap line/hot wire around screw terminal. Tighten securely to 5 in-lb (0.55 N·m).
3 Connect the neutral wire from the wallbox to the white wire on the fan control using a wire connector.
4 Connect the load/tagged wire from the wallbox to the yellow wire on the fan control using a wire connector.

Ground

Troubleshooting

Symptoms

Probable cause and action

Fan does not turn ON and no indicator · Ensure that the fan pull chain is set to highest possible setting.

lights turn ON.

· Load and Line wires may be reversed. Swap wires that are attached to the

yellow wire and black screw terminal on the fan control. Refer to wiring diagram

in step 6.

· Neutral wire is not connected. Refer to wiring diagram in step 6.

· Front Accessible Service Switch (FASS) is in the OFF position. Push FASS in to the ON position.

· Breaker is OFF or tripped (or fuse blown). Reset breaker or replace fuse. If condition persists, contact Lutron Customer Assistance or a licensed electrician.

Fan does not turn ON and indicator lights are ON.
Fan speed is too slow.
Only the high speed appears to be working.

Fan direction switch is between forward and reverse. Set switch to desired position.
Set fan pull chain speed to high.
Sunnata fan is designed to work with AC fan only. Confirm with the fan manufacturer.

CAUTION Use only with permanently installed ceiling fans. To avoid overheating and possible damage to other equipment, do not use to control receptacles, motor-driven appliances, or transformer-supplied appliances.
Codes Install in accordance with all national and local electrical codes.
Grounding When no “grounding means” exist in wallbox, the National Electrical Code (NEC®) allows a control to be installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these methods, cap or remove green wire before screwing control into wallbox.

7 Mount the fan control
+
8 Turn power on at circuit breaker

ON ON OFF OFF

9 Set-Up with system
For use in a HomeWorks system, please refer to www.lutron.com/HWsupport. For reliable performance in a system, Clear Connect-Type X devices must be placed within 25 ft (7.6 m) of two additional compatible Clear Connect-Type X devices. Clear ConnectType X devices include, for example, HomeWorks Sunnata dimmer, switch, keypad and HomeWorks wireless processor / gateway devices. Companion devices are excluded from the list of compatible devices because they are not Clear Connect-Type X devices. Companion devices have wired communication with the main device. For more information please refer to the Wireless Setup guide: www.lutron.com/HWsupport
Operation

On Off

ON:
· Default ­ Fan goes to maximum speed
· See Sunnata Advanced Feature Mode Application Note (P/N TBD) to change this behavior
· Anytime ­ Double tap to maximum speed
Adjust:
(Light Bar) · Touch light bar to set fan to either
one of the 4 speeds (High, MediumHigh, Medium and Low)

FASS · FA

OFF:
· Default – Fan turns off

SS · FASS ·

SS · FASS

· FASS · FA

FASS Switch
(Front Accesible Service Switch) Pull tab out to change the room’s light bulb.