RIDGE RG4 LS1282 Wall Light
Instruction Manual
Contents
RIDGE RG4 LS1282 Wall Light
MODEL | LS1282 |
PART NUMBER | LS1282 – 10 D xxx xx xx 01 xx xx LS1282 – 10 D xxx xx xx 09 xx xx |
INSTALLATION TYPE | Wall Mount (Surface) |
IP RATING | IP66/67 |
SUPPLY VOLTAGE | 220 to 240 Vac, 50 Hz (International) 120/277 Vac, 60 Hz (North America) |
INSTRUCTIONS COVER | Single Color Dimming (DALI, 0-10 V) |
DIMENSIONS (LxWxH) | Refer to included drawings |
WEIGHT | 2.7 lb (1.2 kg) 4.6 lb (2.1 kg) including wiring back box |
AMBIENT TEMPERATURE | 0ºF to 131ºF (-17ºC to 55ºC) |
Tools Required
Included Components
![]() |
CAUTION Risk of Electric Shock |
![]() |
Do Not Use Power Tools on Screws |
![]() |
Keep Electronics Free From Dirt and Moisture |
![]() |
Keep Away from Flammable Materials |
![]() |
Do Not Hose or Pressure Clean |
![]() |
Do Not Use Silicone On Outside Surface |
![]() |
Do Not Cut Cable to the Luminaire |
Please read and follow all safety instructions carefully. Failure to do so will void warranty.
WARNING – Product Warranty is void if product is not installed as per installation instructions and in compliance with all local and provincial codes.
- Ensure installation complies with local electrical rules and regulations.
- All electrical work must be performed by a licensed electrician.
- Protective earth; protective ground (symbol 7).
- For LED Options 3,500K, 4,000K, 5,000K: This product contains a light source of energy efficiency class F.
- All luminaires may become hot. Use discretion on where the luminaire is mounted. Take care when setting luminaire as it may become hot.
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by Lumascape or their service agent in order to avoid a hazard. The light source contained in this luminaire shall only be replaced by Lumascape or their service agent.
- The luminaire should only be used complete with protective shield. If protective shield is cracked, immediately stop using the luminaire, isolate the lighting source, keep it dry and contact Lumascape immediate for replacement (symbol 11).
- Do not stare at the operating light source. The luminaire should be positioned so that prolonged staring into the luminaire at a distance of x m is not expected (symbol 13).
- Basic insulation has been maintained between line voltage and the control conductors.
- To reduce the risk of strangulation the flexible wiring connected to this luminaire shall be effectively fixed to the wall if the wiring is within arm’s reach.
- Ensure mains input power is surge protected.
- Never make or break connections while the circuit is energized.
- Do not make modifications or alter the product.
- Keep luminaire clean and free of debris.
- Only clean with warm water. ) Do not use chemicals or abrasives to clean luminaire as this may void the product warranty.
- Connections are to be kept clean and dry at all times. > Suitable for use indoors or outdoors.
Legend Key:
Assembly Instructions
1-GANG/4″ JUNCTION BOX (NORTH AMERICA)
DRYWALL/PLASTERBOARD (INTERNATIONAL)
CEMENT/BRICKWALL USING WIRING BACK BOX (INTERNATIONAL)
SERVICING/REMOVAL OF LUMINAIRE
Wiring Designations
Designation | Color |
Line | Black |
Neutral | White |
Earth/Ground | Green / Yellow |
Dim + | Purple |
Dim – | Gray |
Do not Hi-Pot test
Dimensions
ARCHITECTURAL & FACADE LIGHTING
Learn more. Visit lumascape.com
IN0236-230511