ID IDENT 4000
RFID and Barcode Reader
Subject to change without prior notice
Copyright © 2022 iDTRONIC GmbH
ID IDENT 4000 User Manual EN v02.docx
Version 02
2022-05-13 / MB
Contents
Disclaimer
Before using the product, please read all the contents in this Product Manual carefully to ensure the safe and effective use of the product. Do not disassemble the product or tear up the seal on the device by yourself, or iDTRONIC will not be responsible for the warranty or replacement of the product.
The pictures in this manual are for reference only. If any individual pictures do not match the actual product, the actual product shall prevail. For the upgrade and update of this product, iDTRONIC reserves the right to modify the document at any time without notice.
Use of this product is at the user’s own risk. To the maximum extent permitted by applicable law, damages and risks arising from the use or inability to use this product, including but not limited to direct or indirect personal damage, loss of commercial profits, iDTRONIC. will not bear any responsibility for trade interruption, loss of business information or any other economic loss.
All rights of interpretation and modification of this manual belong to iDTRONIC
Preface
Thank you for buying the ID IDENT 4000 QR/barcode reader provided by iDTRONIC.
Reading this document carefully can help you understand the functions and features of this device, and quickly master the use and installation of the device.
1.1. Product introduction
The ID IDENT 4000 QR/barcode reader was a specially designed product for access control, which has various output interface, support wiegand and RS485, can connect to the traditional access controller. It also support Ethernet output interface, with built-in relay module.
1.2. Product feature
A. Scan QR/barcode & reading card all in one.
B. Fast recognition, high accuracy, can reach 0.1s the fastest.
C. Easy to operate, more easy to debug with the humanize tool.
D. Built-in relay module, can connect to the access system directly.
Product appearance
2.1.1. OVERALL INTRODUCTION2.1.2. PRODUCT SIZE CHART
Product parameters
3.1. General parameter
General parameter | |
output interface | RS485, wiegand, Ethernet, relay |
indicating method | Red,green, blue, white indication light Beep |
imaging sensor | 300,000 pixel CMOS sensor |
max. resolution | 640*480 |
supported operating systems | Windows (XP, 7, 8, 10) |
installation method | Wall mounted type |
product dimensions | 132*88*21mm |
recognition window size | 60mm*56mm |
product material | Imported PC & tempered glass |
3.2. Recognition parameter
QR code recognition parameter | |
symbologies | QR, PDF417, CODE39, CODE93, CODE128, ISBN10,ITF,EAN13 etc |
supported decoding | mobile phone screen/ printed barcodes |
reading disteance | 15.9mm – 75.68mm(QRCODE: 15mil) |
reading accuracy | > 7mil |
reading speed | 100ms per time (average), support reading continuously |
reading direction | Tilt±59.5° rotation±360° deflection±63.5° (70 character 15milQR) |
FOV | Horizontal 72.4° vertical 54.2° FOV 84.8°(70 character 15milQR) |
RFID parameter
type | ISO 14443A,ISO 14443B protocol |
operation method | read UID, read the sector of M1 card |
frequency | 13.56 Mhz |
distance | < 5cm |
3.3. Electric parameter
The power input can be provided only when the device is connected properly. If the device is plugged in or unplugged while the cable is live (hot plugging), its electronic components will be damaged.
Make sure that the power is turned off when plugging and unplugging the cable.
Poor power supply, too short interval power off and on operation may cause the device cannot work in a stable and normal status. It is necessary to keep the power input stable. After turning off the power input, it need to takes more than 2 seconds to turn on the power input again.
Electric parameter
working voltage | DC 12V – 24V |
working current | 100mA (12V typical value) |
power consumption | 1,2W (12V typical value) |
relay | DC 30V/1A |
3.4. Work environment
work environment parameter
ESD protection | ±8kV (air discharge) ±4kV (direct discharge) |
working temperature | -20°C – 70°C |
storage temperature | -20°C – 70°C |
relative humidity | 5% – 95% (no condensation, under normal temperature) |
ambient light | 0-80000Lux (Non direct sunlight) |
Interface definition
4.1. RS485 & wiegand interface definition
Pin10 | Pin9 | Pin8 | Pin? | Pin6 | Pin5 | Pin4 | Pin3 | Pint | Pinl |
POW | GND | SIGN | NC | COM | NO | WG_D1 | WG_DO | 485A | 48513 |
wiegand wiring diagramRS485 wiring diagram
4.2. Ethernet interface definition
Pin10 | Pin9 | Pin8 | Pin? | Pin6 | Pin5 | Pin4 | Pin3 | Pin2 | Pinl |
POW | GND | SIGN | NC | COM | NO | TX- | TX+ | RX- | RX+ |
ID IDENT 4000 interface | Pin4 | Pin3 | Pin2 | Pinl |
Network cable color | Orange | Orange white | Green | Green white |
ID IDENT 4000 Ethernet model directly leads four network cable pins, and can be connected to four of the standard eight-core network cables according to the color. The network cable uses the 568B type connection method. Refer to the table below and connect the cables according to color.
Wiring diagram (network device)
Device configuration
Use the IDENTconfig tool to configure the device, which can be download from our official website
(For more information about the configuration tool, please refer to the IDENTconfig user manual).
Configure the server address as the step shows:
Step 1: select language and deviceStep 2: select output method
Step 3: configure the server address and the transfer action.
Step 4: use the device to scan the config QR code
Installation method
The product using CMOS image sensor, the recognition window should avoid direct sun or other strong light source when install the scanner. The strong light source will cause the contrast in the image too big to decoding, the long term exposure will damage the sensor and cause the device failure.
The recognition window are using tempered glass, which has good transmission of the light, it also a pressure resistance, but still need to avoid scratching the glass by some hard object, it will affect the QR code recognition performance.
The RFID antenna was in the underside of the recognition window, there should have no metal or magnetic material within 10cm when installing the scanner, or it will affect the card reading performance.
Access scenario application
The scenario is for the ID IDENT 4000 Ethernet device.
7.1. Using scenario diagram
7.2. Access control system wiring diagram
Note: access control solution introduction
- Scanner connect with network, upload the scanned QR data to the specified server.
- The server judge the authority when received the QR data.
- If the QR code matches the door open condition, it will return the scanner a value.
- When the scanner receive the returned value, it will output relay signal, control open the door.
Attention
- The equipment standard is 12-24V power supply, it can get power from the access control power or power it separately. Excessive voltage may cause the device to fail to work normally or even damage the device.
- Do not disassemble the scanner without permission, otherwise the device may be damaged.
- For Ethernet scanner, it is necessary to ensure a good network environment, otherwise it may be unable to communicate with the server.
- The installation position of the scanner should avoid direct sunlight. Otherwise, the scanning effect may be affected. The panel of the scanner must be clean, otherwise it may affect the normal image capture of the scanner. The metal around the scanner may interfere with the RFID magnetic field and affect card reading.
- The wiring of the scanner must be firm. In addition, ensure the insulation between the lines to prevent the equipment from being damaged by a short circuit.
- The output of the scanner is a switch signal. In an access control scenario, it can be connected to the original access control system according to the normally open or normally closed connection method of the original access control system.
Contact info
iDTRONIC GmbH
Ludwig-Reichling-Straße 4
67059 Ludwigshafen
Germany
E-Mail: [email protected]
Web: www.idtronic-wellfit.de
Phone: +49 621 6690094-0
Fax: +49 621 6690094-9
Subject to change without prior notice
Copyright © 2022 iDTRONIC GmbH
ID IDENT 4000 User Manual EN v02.docx
Version 02
2022-05-13 / MB