iDTRONIC ID IDENT 4000 RFID and Barcode Reader Instruction Manual

Home » IDTRONIC » iDTRONIC ID IDENT 4000 RFID and Barcode Reader Instruction Manual

iDTRONIC logoiDTRONIC ID IDENT 4000 RFID and Barcode ReaderID IDENT 4000
RFID and Barcode Reader
Subject to change without prior notice
Copyright © 2022 iDTRONIC GmbH
ID IDENT 4000 User Manual EN v02.docx
Version 02
2022-05-13 / MB

Disclaimer

Before using the product, please read all the contents in this Product Manual carefully to ensure the safe and effective use of the product. Do not disassemble the product or tear up the seal on the device by yourself, or iDTRONIC will not be responsible for the warranty or replacement of the product.
The pictures in this manual are for reference only. If any individual pictures do not match the actual product, the actual product shall prevail. For the upgrade and update of this product, iDTRONIC reserves the right to modify the document at any time without notice.
Use of this product is at the user’s own risk. To the maximum extent permitted by applicable law, damages and risks arising from the use or inability to use this product, including but not limited to direct or indirect personal damage, loss of commercial profits, iDTRONIC. will not bear any responsibility for trade interruption, loss of business information or any other economic loss.
All rights of interpretation and modification of this manual belong to iDTRONIC

Preface

Thank you for buying the ID IDENT 4000 QR/barcode reader provided by iDTRONIC.
Reading this document carefully can help you understand the functions and features of this device, and quickly master the use and installation of the device.
1.1. Product introduction
The ID IDENT 4000 QR/barcode reader was a specially designed product for access control, which has various output interface, support wiegand and RS485, can connect to the traditional access controller. It also support Ethernet output interface, with built-in relay module.
1.2. Product feature
A. Scan QR/barcode & reading card all in one.
B. Fast recognition, high accuracy, can reach 0.1s the fastest.
C. Easy to operate, more easy to debug with the humanize tool.
D. Built-in relay module, can connect to the access system directly.

Product appearance

2.1.1. OVERALL INTRODUCTIONiDTRONIC ID IDENT 4000 RFID and Barcode Reader - OVERALL INTRODUCTION2.1.2. PRODUCT SIZE CHART

iDTRONIC ID IDENT 4000 RFID and Barcode Reader - PRODUCT SIZE CHARTiDTRONIC ID IDENT 4000 RFID and Barcode Reader - PRODUCT SIZE CHART 3

Product parameters

3.1. General parameter

General parameter 
output interface RS485, wiegand, Ethernet, relay
indicating method Red,green, blue, white indication light Beep
imaging sensor 300,000 pixel CMOS sensor
max. resolution 640*480
supported operating systems Windows (XP, 7, 8, 10)
installation method Wall mounted type
product dimensions 132*88*21mm
recognition window size 60mm*56mm
product material Imported PC & tempered glass

3.2. Recognition parameter

QR code recognition parameter 
symbologies QR, PDF417, CODE39, CODE93, CODE128, ISBN10,ITF,EAN13 etc
supported decoding mobile phone screen/ printed barcodes
reading disteance 15.9mm – 75.68mm(QRCODE: 15mil)
reading accuracy > 7mil
reading speed 100ms per time (average), support reading continuously
reading direction Tilt±59.5° rotation±360° deflection±63.5° (70 character 15milQR)
FOV Horizontal 72.4°  vertical 54.2° FOV 84.8°(70 character 15milQR)

RFID parameter

type ISO 14443A,ISO 14443B protocol
operation method read UID, read the sector of M1 card
frequency 13.56 Mhz
distance < 5cm

3.3. Electric parameter
The power input can be provided only when the device is connected properly. If the device is plugged in or unplugged while the cable is live (hot plugging), its electronic components will be damaged.
Make sure that the power is turned off when plugging and unplugging the cable.
Poor power supply, too short interval power off and on operation may cause the device cannot work in a stable and normal status. It is necessary to keep the power input stable. After turning off the power input, it need to takes more than 2 seconds to turn on the power input again.
Electric parameter

working voltage DC 12V – 24V
working current 100mA (12V typical value)
power consumption 1,2W (12V typical value)
relay DC 30V/1A

3.4. Work environment
work environment parameter

ESD protection ±8kV (air discharge) ±4kV (direct discharge)
working temperature -20°C – 70°C
storage temperature -20°C – 70°C
relative humidity 5% – 95%   (no condensation, under normal temperature)
ambient light 0-80000Lux (Non direct sunlight)

Interface definition

4.1. RS485 & wiegand interface definition

Pin10 Pin9 Pin8 Pin? Pin6 Pin5 Pin4 Pin3 Pint Pinl
POW GND SIGN NC COM NO WG_D1 WG_DO 485A 48513

wiegand wiring diagramiDTRONIC ID IDENT 4000 RFID and Barcode Reader - wiring diagram 1RS485 wiring diagram iDTRONIC ID IDENT 4000 RFID and Barcode Reader - wiring diagram 24.2. Ethernet interface definition

Pin10 Pin9 Pin8 Pin? Pin6 Pin5 Pin4 Pin3 Pin2 Pinl
POW GND SIGN NC COM NO TX- TX+ RX- RX+
ID IDENT 4000 interface Pin4 Pin3 Pin2 Pinl
Network cable color Orange Orange white Green Green white

ID IDENT 4000 Ethernet model directly leads four network cable pins, and can be connected to four of the standard eight-core network cables according to the color. The network cable uses the 568B type connection method. Refer to the table below and connect the cables according to color.
Wiring diagram (network device)iDTRONIC ID IDENT 4000 RFID and Barcode Reader - wiring diagram 3

Device configuration

Use the IDENTconfig tool to configure the device, which can be download from our official website
iDTRONIC ID IDENT 4000 RFID and Barcode Reader - icon 2(For more information about the configuration tool, please refer to the IDENTconfig user manual).
Configure the server address as the step shows:
Step 1: select language and deviceiDTRONIC ID IDENT 4000 RFID and Barcode Reader - Step 1Step 2: select output method iDTRONIC ID IDENT 4000 RFID and Barcode Reader - Step 2Step 3: configure the server address and the transfer action. iDTRONIC ID IDENT 4000 RFID and Barcode Reader - Step 3Step 4: use the device to scan the config QR code iDTRONIC ID IDENT 4000 RFID and Barcode Reader - Step 4

Installation method

The product using CMOS image sensor, the recognition window should avoid direct sun or other strong light source when install the scanner. The strong light source will cause the contrast in the image too big to decoding, the long term exposure will damage the sensor and cause the device failure.
The recognition window are using tempered glass, which has good transmission of the light, it also a pressure resistance, but still need to avoid scratching the glass by some hard object, it will affect the QR code recognition performance.
The RFID antenna was in the underside of the recognition window, there should have no metal or magnetic material within 10cm when installing the scanner, or it will affect the card reading performance.iDTRONIC ID IDENT 4000 RFID and Barcode Reader - Step 5

Access scenario application

The scenario is for the ID IDENT 4000 Ethernet device.
7.1. Using scenario diagram

iDTRONIC ID IDENT 4000 RFID and Barcode Reader - Using scenario diagram7.2. Access control system wiring diagram iDTRONIC ID IDENT 4000 RFID and Barcode Reader - wiring diagram 4Note: access control solution introduction

  1. Scanner connect with network, upload the scanned QR data to the specified server.
  2. The server judge the authority when received the QR data.
  3. If the QR code matches the door open condition, it will return the scanner a value.
  4. When the scanner receive the returned value, it will output relay signal, control open the door.

Attention

  1. The equipment standard is 12-24V power supply, it can get power from the access control power or power it separately. Excessive voltage may cause the device to fail to work normally or even damage the device.
  2. Do not disassemble the scanner without permission, otherwise the device may be damaged.
  3. For Ethernet scanner, it is necessary to ensure a good network environment, otherwise it may be unable to communicate with the server.
  4. The installation position of the scanner should avoid direct sunlight. Otherwise, the scanning effect may be affected. The panel of the scanner must be clean, otherwise it may affect the normal image capture of the scanner. The metal around the scanner may interfere with the RFID magnetic field and affect card reading.
  5. The wiring of the scanner must be firm. In addition, ensure the insulation between the lines to prevent the equipment from being damaged by a short circuit.
  6. The output of the scanner is a switch signal. In an access control scenario, it can be connected to the original access control system according to the normally open or normally closed connection method of the original access control system.

Contact info

iDTRONIC logoiDTRONIC GmbH
Ludwig-Reichling-Straße 4
67059 Ludwigshafen
Germany
E-Mail: [email protected]
Web: www.idtronic-wellfit.de
Phone: +49 621 6690094-0
Fax: +49 621 6690094-9
Subject to change without prior notice
Copyright © 2022 iDTRONIC GmbH
ID IDENT 4000 User Manual EN v02.docx
Version 02
2022-05-13 / MB

Leave a Comment