Haier AD35S2SM3FA Multi Split Inverter Slim Duct Indoor AC Unit User Guide

Home » Haier » Haier AD35S2SM3FA Multi Split Inverter Slim Duct Indoor AC Unit User Guide

Haier log

DUCTED MEDIUM PRESSURE
NEW

COMPACT DESIGN

The unit has a thickness of 248 mm which allows better adaptation and ease of installation.

Haier AD35S2SM3FA Multi Split Inverter Slim Duct Indoor AC Unit

CONDENSATE DRAIN
The medium-pressure ducted units includes a condensate drain pump as standard. This guarantees a maximum prevalence of 600 mm measured from the base of the machine.
There is the possibility of performing condensate drain by gravity (reversible on both sides).

Haier AD35S2SM3FA Multi Split Inverter Slim Duct Indoor AC Unit - DRAIN

EASY INSTALLATION

  • The connection of electrical cables is now possible through only one screw.
  • The ducted units have two options for connecting the air extraction channel: rear or lower.

Haier AD35S2SM3FA Multi Split Inverter Slim Duct Indoor AC Unit - DRAIN 1

WiFi
Besides normal wired/infrared control. Haier supplies Smart Control from hOn APP. Including the on/off. operation mode selection, fan speed temperature, and air flow adjustment, schedule, UV function and steri-clean 56 O C, etc.

FRESH AIR
Air exchange allows introduction of clean air into the room.
UVC Sterilisation
The built-in LED UV lights kill airborne hazards when the air circulates from air inlet, ensuring the clean air out.

Flexible air distribution
The ducted units satisfy multiple installation solutions (circular or rectangular channels).

DUCTED MEDIUM PRESSURE

3,5 kW
5,0 kW
7,1 kW
OPTIONAL CONTROL
MONOSPLIT

  • Low noise level
  • Compact design
  • ‘Fresh air’ knockout is incorporated in the chassis to allow fresh air introduction of up to 20% of nominal unit air flow without compromising the cooling capacity. Condensate drain pump
  • UCV Sterilisation
  • Wi-Fi control integrated
INDOOR UNIT Model AD35S2SM3FA(H) AD50S2SM3FA(H)

AD71S2SM3FA(H)

OUTDOOR UNIT Performance data Model 1U35S2SM1FA-2 1U50S2SJ2FA-2 1U71S2SR2FA
Output power – COOLING nom (min-max) kW 3,50 (0,90-4,50) 5,00 (1,80-6,00) 7,10 (2,00-8,20)
Output power – HEATING nom (min-max) kW 4,00 (1,00-4,80) 6,00 (2,00-6,20) 7,50 (2,50-8,50)
Absorbed power – COOLING nom (min-max) kW 1,08 (0,28-1,80) 1,55 (0,55-2,00) 2,20 (0,50-3,00)
Absorbed power – HEATING nom (min-max) kW 1,08 (0,28-1,80) 1,48 (0,60-2,00) 2,02 (0,60-3,00)
Energy class EER W/W 3,23 3,23 3,23
COP W/W 3,71 3,71 3,71
COOLING Pdesign 35 °C kW 3,50 5,00 7,10
HEATING Pdesign (-10 °C) kW 2,70 4,50 5,00
Energy class SEER 6,10 (A++) 6,10 (A++) 6,10 (A++)
SCOP 3,80 (A) 3,80 (A) 3,80 (A)
Annual Energy Consumption – COOLING kWh/a 215 291 406
Annual Energy Consumption – HEATING kWh/a 1020 1782 1827
Indoor Unit
Power supply Ph/V/Hz 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60
Treated air volume (H/M/L/Q) m3/h 840/720/600/450 1020/900/780/550 1440/1260/1100/900
External static pressure Pa 25(default)/37/50/70/90/100/110/120/130/150
High sound power dB 55 56 58
Sound pressure dB(A) 41/35/28/26 43/37/30/28 44/41/39/36
Net dimensions WxDxH mm 700x700x248 1100x700x248 1100x700x248
Packaging dimensions WxDxH mm 914x866x318 1316x866x318 1316x866x318
Net/gross weight kg 26,0/30,0 31,0/35,0 31,0/35,0
Outdoor Unit
Power supply Ph/V/Hz 1/220~240/50 1/220~240/50 1/220~240/50/60
Power cable N x mm2 3 x 1,5 3 x 1,5 3 x 4,0
Interconnection cable N x mm2 4 x 1,0 4 x 1,0 4 x 2,5
Sound power H dB 61 63 67
Sound pressure H dB(A) 48 50 54
Running current cooling/heating Max A 8,0 10,68 13,1
Starting current cooling/heating Max A 2,0 2,0 2,0
Net dimensions WxDxH mm 800x275x553 820x305x643 890x340x700
Packaging dimensions WxDxH mm 902x375x607 940x390x697 1046x460x780
Net/gross weight kg 30,0/32,9 35,7/38,5 45,0/50,0
Compressor type Rotary inverter Rotary inverter Twin rotary inverter
Installation data
Refrigerant R32 R32 R32
Liquid pipe Ø mm (inch) 6,35 (1/4) 6,35 (1/4) 9,52 (3/8)
Gas pipe Ø mm (inch) 9,52 (3/8) 12,70 (1/2) 15,88 (5/8)
Standard pipe length without refrigerant charge m 7 7 10
Maximum pipe length m 20 25 50
Maximum IU – OU elevation m 10 15 30
Refrigerant charge in the factory kg 0,78 1,10 1,30
Refrigerant charge in the factory TCO2eq 0,53 0,74 0,88
Additional ref. charge over std length g/m 20 20 45
Outdoor operating limits – COOLING min-max °C -20~46
Outdoor operating limits – HEATING min-max °C -20~24
  • Low noise level
  • Compact design
  • Fresh air’ knockout is incorporated in the chassis to allow fresh air introduction of up to 20% of nominal unit air flow without compromising the cooling capacity. Condensate drain pump
  • UCV Sterilisation
  • Wi-Fi control integrated
INDOOR UNIT Model AD105S2SM3FA(H) AD105S2SM3FA(H) AD125S2SM8FA(H)

AD125S2SM8FA(H)

OUTDOOR UNIT Performance data Model 1U105S2SS2FA 1U105S2SS1FB 1U125S2SN2FA 1U125S2SN2FB
Output power – COOLING nom (min-max) kW 9,50 (2,50-10,00) 9,50 (2,50-10,00) 12,30 (3,00-13,00) 12,40 (3,00-13,00)
Output power – HEATING nom (min-max) kW 10,20 (3,00-10,50) 10,50 (3,00-11,00) 12,70 (3,50-13,50) 12,80 (3,50-13,50)
Absorbed power – COOLING nom (min-max) kW 3,16 (0,50-4,00) 3,27 (0,50-4,00) 4,60 (1,00-6,00) 4,51 (1,00-6,00)
Absorbed power – HEATING nom (min-max) kW 2,91 (0,50-4,00) 3,00 (0,50-4,00) 3,93 (1,00-6,00) 3,87 (1,00-6,00)
Energy class EER W/W 3,01 2,90 2,67 2,75
COP W/W 3,50 3,50 3,23 3,31
COOLING Pdesign 35 °C kW 9,50 9,50 12,30 12,40
HEATING Pdesign (-10 °C) kW 7,20 6,00 8,00 8,00
Energy class SEER 6,10 (A++) 6,00 (A+) 5,72 (A+) 5,85 (A+)
SCOP 3,80 (A) 3,91 (A) 3,93 (A) 3,96 (A)
Annual Energy Consumption – COOLING kWh/a 544 569 735 718
Annual Energy Consumption – HEATING kWh/a 2792 2094 3032 3003
Indoor Unit
Power supply Ph/V/Hz 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60
Treated air volume (H/M/L/Q) m3/h 1600/1480/1360/1240 1600/1480/1360/1240 2250/1960/1680/1500 2250/1960/1680/1500
External static pressure Pa 25/37(default)/50/70/90/100/110/120/130/150
High sound power dB 61 64 65 65
Sound pressure dB(A) 47/44/40/37 47/44/40/37 48/45/42/39 48/45/42/39
Net dimensions WxDxH mm 1500x700x248 1500x700x248 1500x700x248 1500x700x248
Packaging dimensions WxDxH mm 1711x870x325 1711x870x325 1711x870x325 1711x870x325
Net/gross weight kg 46,0/55,0 46,0/55,0 48,0/57,0 48,0/57,0
Outdoor Unit
Power supply Ph/V/Hz 1/220~240/50/60 3/380~415/50/60 1 /220~240/ 50/60 3 /380-415/ 50/60
Power cable N x mm2 3 x 4,0 5 x 4,0 3 x 6,0 5 x 4,0
Interconnection cable N x mm2 4 x 2,5 4 x 2,5 4 x 2,5 4 x 2,5
Sound power H dB 66 68 72 72
Sound pressure H dB(A) 53 54 58 58
Running current cooling/heating Max A 16,5 6,8 26,0 10,0
Starting current cooling/heating Max A 3,0 1,0 4,0 2,0
Net dimensions WxDxH mm 920*372*765 920*372*765 950x370x965 950x370x965
Packaging dimensions WxDxH mm 1036*478*820 1085x485x830 1050x485x1130 1050x485x1130
Net/gross weight kg 60,0/65,0 61,0/66,0 84,0/89,0 85,0/90,0
Compressor type Twin rotary inverter Twin rotary inverter Twin rotary inverter Twin rotary inverter
Installation data
Refrigerant R32 R32 R32 R32
Liquid pipe Ø mm (inch) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8)
Gas pipe Ø mm (inch) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8)
Standard pipe length without refrigerant charge m 30 30 30 30
Maximum pipe length m 50 50 50 50
Maximum IU – OU elevation m 30 30 30 30
Refrigerant charge in the factory kg 1,70 1,70 2,30 2,30
Refrigerant charge in the factory TCO2eq 1,15 1,15 1,55 1,55
Additional ref. charge over std length g/m 45 45 45 45
Outdoor operating limits – COOLING min-max °C -20~46
Outdoor operating limits – HEATING min-max °C -20~24
  • Low noise level
  • Compact design
  • ‘Fresh air’ knockout is incorporated in the chassis to allow fresh air introduction of up to 20% of nominal unit air flow without compromising the cooling capacity. Condensate drain pump
  • UCV Sterilisation
  • Wi-Fi control integrated
INDOOR UNIT                               Model                               AD140S2SM8FA(H) AD140S2SM8FA(H) AD140S2SM8FA(H) AD140S2SM8FA(H) AD160S2SM3FA(H)
OUTDOOR UNIT

Performance data

Model 1U140S2SN1FA 1U140S2SN1FB 1U140S2SP2FA 1U140S2SP2FB 1U160S2SP1FB
Output power – COOLING nom (min-max) kW 13,40 (3,50-14,00) 13,40 (3,50-14,00) 13,40 (4,00-15,00) 13,40 (4,00-15,00) 16,00 (4,50-16,50)
Output power – HEATING nom (min-max) kW 15,00 (4,00-15,50) 15,00 (4,00-15,50) 15,00 (4,50-16,00) 15,00 (4,50-16,00) 17,00 (5,00-18,00)
Absorbed power – COOLING nom (min-max) kW 5,28 (1,00-6,50) 5,18 (1,00-6,50) 4,17 (1,00-6,00) 4,15 (1,00-6,00) 5,48 (1,00-6,50)
Absorbed power – HEATING nom (min-max) kW 4,92 (1,00-6,50) 4,79 (1,00-6,50) 4,04 (1,00-6,00) 4,02 (1,00-6,00) 4,82 (1,00-6,50)
Energy class EER W/W 2,54 2,59 3,21 3,23 2,92
COP W/W 3,05 3,13 3,71 3,73 3,53
COOLING Pdesign 35 °C kW 13,40 13,40 13,40 13,40 16,00
HEATING Pdesign (-10 °C) kW 8,50 8,50 11,00 11,00 11,00
Energy class SEER 5,62 (A+) 5,64 (A+) 6,16 (A++) 6,19 (A++) 5,94 (A+)
SCOP 3,93 (A) 3,96 (A) 4,06 (A+) 4,06 (A+) 4,06 (A+)
Annual Energy Consumption – COOLING kWh/a 835 832 761 758 943
Annual Energy Consumption – HEATING kWh/a 3032 3003 3796 3798 3798
Indoor Unit
Power supply Ph/V/Hz 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60 1/220~240/50/60
Treated air volume (H/M/L/Q) m3/h 2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500 2500/2160/1780/1500
External static pressure Pa 25/37(default)/50/70/90/100/110/120/130/150
High sound power dB 66 66 66 66 67
Sound pressure dB(A) 48/45/42/39 48/45/42/39 48/45/42/39 48/45/42/39 48/45/42/39
Net dimensions WxDxH mm 1500x700x248 1500x700x248 1500x700x248 1500x700x248 1500x700x248
Packaging dimensions WxDxH mm 1711x870x325 1711x870x325 1711x870x325 1711x870x325 1711x870x325
Net/gross weight kg 48,0/57,0 48,0/57,0 48,0/57,0 48,0/57,0 48,0/57,0
Outdoor Unit
Power supply Ph/V/Hz 1 /220~240/ 50/60 3 /380-415/ 50/60 1/220~240/50/60 3/380~415/50/60 3/380~415/50/60
Power cable N x mm2 3 x 6,0 5 x 4,0 3 x 6,0 5 x 4,0 5 x 4,0
Interconnection cable N x mm2 4 x 2,5 4 x 2,5 4 x 2,5 4 x 2,5 4 x 2,5
Sound power H dB 72 72 70 70 72
Sound pressure H dB(A) 58 58 53 53 58
Running current cooling/heating Max A 30,0 10,0 32,0 10,0 10,0
Starting current cooling/heating Max A 5,0 2,0 6,0 2,0 2,0
Net dimensions WxDxH mm 950x370x965 950x370x965 950x370x1350 950x370x1350 950x370x1350
Packaging dimensions WxDxH mm 1050x485x1130 1050x485x1130 1050x485x1500 1050x485x1500 1050x485x1500
Net/gross weight kg 84,0/89,0 85,0/90,0 105,0/118,0 101,0/116,0 101,0/116,0
Compressor type Twin rotary inverter Twin rotary inverter Twin rotary inverter Twin rotary inverter Twin rotary inverter
Installation data
Refrigerant R32 R32 R32 R32 R32
Liquid pipe Ø mm (inch) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8) 9,52 (3/8)
Gas pipe Ø mm (inch) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 15,88 (5/8) 19,05 (3/4)
Standard pipe length without refrigerant charge m 30 30 30 30 30
Maximum pipe length m 70 70 70 70 70
Maximum IU – OU elevation m 30 30 30 30 30
Refrigerant charge in the factory kg 2,30 2,30 2,90 3,50 3,50
Refrigerant charge in the factory TCO2eq 1,55 1,55 1,96 2,36 2,36
Additional ref. charge over std length g/m 45 45 45 45 45
Outdoor operating limits – COOLING min-max °C -20~46
Outdoor operating limits – HEATING min-max °C -20~24

The data in this catalogue is purely indicative as the data may vary. Please be advised to check the accuracy of the data with the supplier before purchasing products.