Original instructions
IR3000, IR4500, IR6000
Contents
IR3000 Infrared Heater
Ecodesign Regulation (EU) 2015/1188 concerning local space heaters does not apply to all application areas.
The Regulation applies when an installation is intended to provide thermal comfort for people in the premises. The Regulation does not apply to heating installations of a more technical nature e.g. in engineering/utility rooms, in production processes, frost protection, etc. The Regulation also does not apply to installations in vehicles, offshore or outdoors. Many of Frisco’s products can be used as both local space heaters (as defined in (EU) 2015/1188) and for technical heating purposes. It is up to the installer responsible for the installation to assess whether the Ecodesign Regulation is applicable or not. Control solutions for installations not covered by the Ecodesign Regulation are listed in a separate table.
Type | L1 [mm] | L2 [mm] |
IR3000 | 600 | 1125 |
IR4500 | 900 | 1500 |
IR6000 | 1200 | 1875 |
Minimum distances
[mm] |
||
Ceiling | A | 400 |
Wall, long side of the unit | B | 400 |
Wall, short side of the unit | C | 400 |
Flammable material | D | 700 |
Floor | E | 2300 |
Type | HxWxD [mm] |
IRG3000 | 869x362x40 |
IRG4500 | 1235x362x40 |
IRG6000 | 1615x362x40 |
Controls
Type | HxWxD [mm] |
TAP16R | 87x87x53 |
TEP44 | 87x87x55 |
RB3 | 155x87x43 |
RB123 | 155x87x43 |
RTX54 | 82x88x25 |
SKG30 | 115x85x40 |
PDK65 | 102x70x50 |
Controls for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Type | HxWxD [mm] |
KRT1900 | 165x57x60 |
KRTV19 | 165x57x60 |
S123 | 72x64x46 |
Technical specifications
Type | Output steps [kW] | Voltage [V] | Amperage [A] | Max. element temperature[°C] | Dimensions LxHxW [mm] | Weight [kg] |
IR3000 | 1/2/2003 | 400V3N~* | 4,3 | 700 | 1125x83x358 | 9 |
IR4500 | 1.5/3/4.5 | 400V3N~* | 6,5 | 700 | 1500x83x358 | 11.1 |
IR6000 | 2/4/2006 | 400V3N~* | 8,7 | 700 | 1875x83x358 | 13.2 |
*) Can also be connected 400V3~, but then without output steps. With neutral, one element tube at a time can be connected.
Protection class: IP44.
CE compliant.
Wiring diagrams
Internal wiring diagram
Control by thermostat and relaybox
Control by thermostat, relaybox and black bulb sensor
Control by relaybox with 3 step output control and presence detector
Control by thermostat, contactor and switch – for installations not covered by the Ecodesign Regulation (EU) 2015/1188
Main office Frico AB Industrivägen 41
SE-433 61 Sävedalen Sweden
Tel: +46 31 336 86 00
[email protected]
www.frico.net
For latest updated information and information about your local contact: www.frico.net
Artnr. 204566, 2022-10-10 ZD