FORENEX FR-48522W Breakout Board Installation Guide

Home » FORENEX » FORENEX FR-48522W Breakout Board Installation Guide

FR-48522
(RS422/ 485) Breakout Board
Quick Install Guide (QIG) Preliminary

General Description

Making UART-TTL logical level convert to RS422/ RS485

Feature:

UART-TTL with 3.3V/ 5V tolerance input.
An optional 120 Ohm (Terminate Resistor) built on board.
RoHS Compliant.

Ordering Information:
FR-48522W: with wire to board connector.
FR-48522D: with board to board Header.
WC7067060153: 6-pin to 6-pin, wire cable for input, L=150mm.

Connector:

UART-TTL Connector
UART3: (Wafer-6pin, 1.25mm, 90°) FR-48522W only JP3: (Header-5pin, 2.0mm, 180°) FR-48522D only
Pin num. Description I/O Pin num Description I/O
Pint Power Input (3.3V/ 5V) P Pint Power Input (3.3V/ 5V) P
Pin2 UART-TX I Pin2 UART-TX I
Pin3 UART-RX 0 Pin3 UART-RX 0
Pin4 GND P Pin4 GND P
Pin5 UART-RTS I Pin5 UART-RTS I
Pin6 NC

* The UART-RTS is a data-flow direction control pin, only available as FR-48522 is set to RS485mode. Driving the UART-RTS to low will receive data from FR-48522.

Terminate Resister Jumper: (Header-2x2pin, 2.0mm, 180°)
Pin  Description 
AY/BZ side Set terminate resister for the output of RS422 or RS485.
A/B side Set terminate resister for the input channel of RS422 only.
Terminal Block Connector: (5-pin, Male, 90°)
Pin num. Symbol Jumper(J-RX) set on 422 side Jumper(J-RX) set on 485 side
RS422 mode RS485 mode
Description I/O Description I/O
Pint GND Ground Ground
Pin2 AY Output Channel+ 0 In/Out Channel+ I/O
Pin3 BZ Output Channel- 0 In/Out Channel- I/O
Pin4 A Input Channel+ I NC
Pin5 B Input Channel- I NC

Dimension: