EVOHEAT Evo270-1 Hot Water Heat Pump Instruction Manual

Home » EVOHEAT » EVOHEAT Evo270-1 Hot Water Heat Pump Instruction Manual

EVOHEAT logoINSTALLATION & OPERATION MANUAL
Evo270-1 Hot Water Heat Pump EVOHEAT Evo270 1 Hot Water Heat Pump

Evo270-1 Hot Water Heat Pump

EVOHEAT Evo270 1 Hot Water Heat Pump - Figure

Introduction

This manual contains information relating to the installation, troubleshooting, operation, and maintenance of this EvoHeat unit. Instructions in this manual must always be followed. Failure to comply with these recommendations will invalidate the warranty. Should you have any questions or require technical support, call the EvoHeat office on 1300 859 933 to speak to our team.

TECHNICAL DATA  Evo270-1 
Storage Capacity L 270
Max Temperature Setting ˚C 60
Power Input kW 0.94
Heating Output kW 3.6
C.O.P at 20˚C Air  4.27
Noise Rating dB(A) 48
Running Current A 3.9
Power Supply 220-240V/1/50Hz
Water Inlet/Outlet Size mm 20 (3/4”)
Auxiliary Heating kW 1.5
Operating Temperature Range ˚C -5 to 43
Hot Water Recovery L/hr 89
With Hydro Boost L/hr 119
Net Weight kg 130

EVOHEAT Evo270 1 Hot Water Heat Pump - Figure 2The EVO 270-1 is the next evolution in water heating with advanced energy efficiency technologies and built-in smart features to ensure you’re provided with clean, safe, and economical hot water all year round.
Conforms to AS 3498-2020 Australia and New Zealand
Measurement conditions: Instant heating: Ambient air temperature 20°C/15°C, water inlet 15°C, water outlet 55°C, highest setting temperature: 75°C
Working Temp Range

  1. Ambient temperature is -5°C ~ 43°C (Heat Pump)
  2. The max temperature of water tank is 70

Operating parameters: The range of the operating water pressures: 0.15~0.7MPa

Dimensions

EVOHEAT Evo270 1 Hot Water Heat Pump - Dimensions

Evo270-1 DIAMETER 
1992 1443 593 1211 1111 640

DO NOT DRILL
Do not drill any fixings or attachments into the outer casing of the tank. Drilling into the outer casing of the tank may damage the heating coil and WILL VOID WARRANTY.

INITIAL STARTUP

  1. Press and hold EVOHEAT Evo270 1 Hot Water Heat Pump - icon 1 for one second to power on the unit.
  2. To set the time:
    a. Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 2 once so the hour digit starts flashing,
    b. Use EVOHEAT Evo270 1 Hot Water Heat Pump - icon 3 to adjust the hour and press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 2 to confirm,
    c. Repeat for the minute, day, month and year,
    d. Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 1 at any stage to cancel.
  3. Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 4 until EVOHEAT Evo270 1 Hot Water Heat Pump - icon 5 is displayed. This will activate “Eco Heating” (Heat Pump only) mode and will provide the most efficient heating.
  4. During periods of unusually high hot water demand (such as additional occupants staying with you), you can activate “High Requirement” mode by pressing EVOHEAT Evo270 1 Hot Water Heat Pump - icon 4 until EVOHEAT Evo270 1 Hot Water Heat Pump - icon 6 is displayed.
  5. In any event where there is a failure within the system, the Electric Element (Hydroboost Mode) can be engaged with “one push activation” of the EVOHEAT Evo270 1 Hot Water Heat Pump - icon 7 button until EVOHEAT Evo270 1 Hot Water Heat Pump - icon 8 is displayed. This will provide emergency water heating until service can be attended.
  6. For adjustment of timers or activating vacation mode, please refer to our online tutorials at: www.evoheat.com.au/tech-support

Safety Instructions

EVOHEAT Evo270 1 Hot Water Heat Pump - icon 9 Ensure that all safety instructions and recommendations are always adhered to. Failure to comply with these recommendations could void the warranty and cause injury or death.

  • Installation, repair, or relocations must only be done by a fully qualified technician.
  • The Evo270-1 must be installed to conform to all relevant Australian Standards and Industry Codes including but not limited to: Electrical & Electrical Safety, Plumbing & Hot Water Storage, Heat Pump Installation & Operation
  • A circuit breaker must be installed for the unit.
  • Ensure the unit has a good power connection and earthing to avoid the risk of electrical shocks.
  • Ensure that there are no leaks on both the plumbing and drainage fittings.
  • The unit must not be installed near flammable gas or have flammable aerosols sprayed in the vicinity.
  • The base that the unit is installed on must be level and stable.
  • If the supply cord is damaged, it must be replaced by a qualified service agent.
  • This appliance must be installed in accordance with national wiring regulations.
  • Installation must also comply with any local, state or federal codes at the installation site. Failure to comply can void your warranty, damage your unit or possible cause injury or death. Plumbing must comply with AS/NZS3500.4
  • Before obtaining access to terminals all supply circuits must be disconnected.
  • A P&T valve MUST be installed in the tank. When the tank pressure reaches 0.85MPa or when the tank temperature reaches 99°C, the P&T valve will open automatically so as to reduce the pressure or temperature decrease.
  • In the event of the unit malfunctioning, shut off the power supply and contact your supplier or EvoHeat.
  • In order to use the unit correctly, run the unit at environment temperature -5°C – 43°C
  • The unit contains sophisticated electronic devices, do not use unsafe water sources such as lake or groundwater.
  • The unit produces hot water and will also have hot fittings, therefore should not be touched to avoid injury.
  • Do not drill any fixings or attachments into the outer casing of the tank. Drilling into the outer casing of the tank may damage the heating coil and WILL VOID WARRANTY.
  • If the unit stops and you restart the unit or turn it on manually, the unit will not start to run again for approximately 3 minutes. This is a protection feature to safeguard the compressor.
  • The handle of the P&T safety valve should be tested once every six months to remove the calcium carbonate deposits and guarantee there is no blockage in the device.
  • Once installation is complete, check that all connections are secure before the power is turned on.
  • The installer is to explain to the end user how to operate and maintain the unit in accordance with this instruction manual.
  • Evo Industries Australia Pty Ltd will not be held responsible for any damages or injuries caused by the incorrect installation of this hot water system.
  • A maintenance programme must be carried out as recommended in this manual to ensure ongoing reliability.

To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and pressure protective equipment required by local codes and no less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSIZ21.22. This valve must be marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater. Install the valve into an opening provided and marked for this purpose in the water heater, and orient it or provide tubing so that any discharge from the valve exits only within 6 inches above, or at any distance below, the structural floor, and does not contact any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances.
Hydrogen gas is produced in a hot water system served by this heater that has not been used for a long period of time (2 weeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance.
The appliance is fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category lll conditions, and these means must be incorporated in the fixed wiring in accordance with the wiring rules.
WARNING
THIS PRODUCT CONTAINS A BUTTON BATTERY
If swallowed, a lithium button battery can cause severe or fatal injuries within 2 hours.
Keep batteries out of reach of children.
If you think batteries may have been swallowed or placed inside any part of the body, seek immediate medical attention.

Installation

5.1 System Installation
Upon receiving the unit, check the packaging for any obvious signs of damage. Inform EvoHeat immediately if there is any evidence of rough handling.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 9 Do not drill any fixings or attachments into the outer casing of the tank. Drilling into the outer casing of the tank may damage the heating coil and WILL VOID WARRANTY.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 9 The P&T valve attached with the unit must be installed. Failure to do so will cause damage to the unit and possible personal injury.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 9 Drain the water tank through the drain valve at the bottom part of the unit.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 9 Do not use stainless steel fittings to connect directly with other metals to prevent galvanic corrosion.

Note: A pressure releasing valve is to be fitted within the installation. Spec of P&T valve: Pressure: 0.85MP Temperature: 99°CEVOHEAT Evo270 1 Hot Water Heat Pump - System InstallationWater Inlet or Outlet Pipes: The specification of the water inlet and outlet thread is BSP3/4 (internal thread). Pipes must be heat-resistant and durable.EVOHEAT Evo270 1 Hot Water Heat Pump - SymbolPiping for the P&T Valve:
The spec of the valve connecting thread is BSP3/4 (internal thread). After installation, confirm that the drainpipe outlet is exposed in the air. When the flexible drainpipe is joined to the pressure relief orifice of this valve, ensure that the flexible drainpipe is pointing downwards and exposed in the air.

5.2 Handing & Transportation
The unit should be stored and/or transported in its shipping container in an upright position and without water charge.
For transport over short distances, and provided due care is exercised, an inclination angle of up to 30 degrees is permitted. During transport and storage, ambient temperatures of -10 to +60 degrees Celsius are permissible.

Forklift Transportation
The unit must remain mounted on the pallet and lifted at minimal speed. Due to its top heaviness, the unit must be secured against tipping over and placed on a level surface.

Manual Transportation
Ensure that the maximum permissible inclination angle of 60 degrees is not exceeded. If transport in an inclined position cannot be avoided, the unit should be left to rest at least one hour after it has been moved into final position before operation.

5.3 Location of Installation
The Evo270-1 is designed for external installation, however, where possible installing the unit under the house eaves or in a sheltered environment may help prolong the life of the system.
Heat pumps operate most efficiently with warmer air temperatures, and the outlet air from the unit will always be colder than the inlet air. Therefore, it is advisable to install the unit so it receives the warmest air temperatures possible and that the cold air is not able to recirculate back into the unit.
5.3.1 Indoor Installation

  • The unit may be able to be installed in an unventilated room exceeding 25m³ in volume.
  • Venting of cold air is advised to prevent the air temperature dropping and lowering the efficiency of the unit.
  • Think of the unit as a 3kW air conditioner for the effect it will have on a closed room.

TO COOL A ROOM
Install the unit so the outlet from the heat pump is blowing INTO the room. The room MUST have some form of air outlet otherwise the performance of the unit will suffer significantly.

TO MAINTAIN NORMAL ROOM TEMPERATURE
Install the unit so the outlet from the heat pump is blowing OUTSIDE the room. The room MUST have some form of air inlet otherwise the performance of the unit will suffer significantly.

5.4 Airflow Clearances EVOHEAT Evo270 1 Hot Water Heat Pump - Airflow ClearancesThe Evo270-1 must be installed with sufficient clearances to allow airflow to circulate through the unit, it is advised to keep a minimum gap between walls/fences etc of:

  • 300mm on the air inlet side
  • 500mm on the air outlet side
  • 100mm overhead & rear clearance

Without sufficient airflow, discharged cold air will recirculate into the unit and consequently lower the heating efficiency.
If the installation location does not comply with these suggested clearances, contact EvoHeat’s Tech Support to discuss possible solutions.

5.5 Cable Connection
The power cable for power supply of the unit is stored in the back of the unit. The unit requires an isolating switch as required by local laws. If the power cord is damaged, it must be replaced by a qualified electrician.

5.6 Filling the Tank
Open a hot water tap inside the house. Open the cold-water inlet valve into the Evo270-1 to fill the tank. When water begins flowing out of the hot water tap inside the premises, turn off the hot water tap.

5.7 Initial Start-Up
PRE-INSPECTION
Check the water supply to the tank and pipe connections for possible leaks.
Check that the following devices are installed and operating correctly:

  • Drainpipes
  • P&T Valve
  • Filter on inlet
  • Water softening and pressure reducing devices if required.

Check that all power connections are secure before switching on.
Check that the installation space is adequate.
TRIAL OPERATION
Switch on the unit by using the controller.
If any unusual noises occur, switch the power off and consult your provider.
The parameters have been pre-set to a temperature of 60 degrees. Check that the unit is operating by looking for an increase in water temperature over time.

Operation

6.1 The Controller EVOHEAT Evo270 1 Hot Water Heat Pump - The Controller

EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 ON/OFF Turn the unit on or off.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 11 UP Select options to increase values
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 12 DOWN Select options to decrease values
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 13 CLOCK Set the clock or the timer.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 14 HYDROBOOST Turn on/off the electric heater
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 15 MODE Switch unit running modes or save setting parameters
EVOHEAT Evo270 1 Hot Water Heat Pump - TOUCH TIMING TOUCH TIMING Touch timing settings
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 20 HEATING MODE The unit will start according to the water temperature and target temperature. The electric heater will not start immediately. After 200 minutes, the unit will judge if it has reached target temperature. If not, the electric heater will start.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 21 ECO HEATING MODE The heat pump system will start according to the water temperature and target temperature. The electric heater always will be off.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 22 INTELLIGENT MODE The unit will automatically judge the operation mode according to the ambient temperature.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 23 HIGH REQUIREMENT MODE The difference between heating mode and high requirement mode is the delay time of electric heater. In the high demand mode, the electric heater will start without delay, which can help the user to heat water quickly in a short time.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 24 VACATION MODE Enable Vacation mode
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 25 FAN Fan is on
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 26 HYDROBOOST The Hydroboost setting is on
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 27 DEFROST The unit is defrosting
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 28 LOCK Keyboard is locked
SET PARAMETERSETTING Parameter is adjustable
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 29 SET TEMP REACHED Set temperature has been reached and the unit will shut off automatically
DOWN LOWER TANK TEMP Temperature of the lower tank
min MINUTE Minute value is being set
s SECOND Second value is being set
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 30 WI-FI State of Wi-Fi connection
*Only available as an optional upgrade

6.2 Operating Functions
EvoHeat have developed a YouTube Channel with video walkthroughs of the different controller functions.
EVOHEAT Evo270 1 Hot Water Heat Pump - qr codeScan the QR code or head to our channel to view the videos we have available https://www.youtube.com/@evoheatpumps

6.2.1 Startup & Shutdown

Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 and hold for 0.5 seconds in the standby screen of the controller to turn the unit on. The main display will now show the water outlet temperature.
Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 and hold for 0.5 seconds in the running screen of the controller to turn the unit off. The main display will now show “OFF”.
The unit will dim the screen and display the standby screen when the controller has not been touched for a minute. Touch the power button to wake it.
Note: The ON/OFF button can only be used to turn the unit on/off in standby or on the running screen of the controller. EVOHEAT Evo270 1 Hot Water Heat Pump - Startup & Shutdown6.2.2 Switching Modes
We recommend running the unit in Eco Heating mode where possible for maximum energy efficiency.
From the running screen, press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 15 to select one of the modes: Heating, Eco Heating, Intelligent, High requirement, Vacation. EVOHEAT Evo270 1 Hot Water Heat Pump - Switching Modes6.2.3 Locking the Controller
To both lock and unlock the controller, press and hold the EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 button for 5 seconds.
When the controller is locked, a lock symbol will appear on the bottom right.

6.2.4 Setting & Checking the Target Temperature
In the standby or running interface, press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 11 or EVOHEAT Evo270 1 Hot Water Heat Pump - icon 12 once to check the target temperature of the outlet water.
Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 11 or EVOHEAT Evo270 1 Hot Water Heat Pump - icon 12 again to change the target temperature.
After making changes to the desired temperature, press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 15 to confirm or EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 to cancel, then return to the previous screen.
If the keypad is left idle for 5 seconds, the controller will exit the menu automatically and apply any changes that were made.
Example: The target temperature is 40°C, the actual outlet water temperature is 18°C.EVOHEAT Evo270 1 Hot Water Heat Pump - water temperature6.2.5 Hydroboost Setting
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 31 Also known as the Electric heater, the Hydroboost setting allows higher levels of hot water to be produced. When there are high hot water usage requirements (such as guests staying), this function may come in useful.
The Hydroboost setting can be turned on when the unit is in heating or in standby mode.
Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 14 once to turn on Hydroboost on or off.
When activated, EVOHEAT Evo270 1 Hot Water Heat Pump - icon 34 will light up on the main display.EVOHEAT Evo270 1 Hot Water Heat Pump - Hydroboost Setting

6.2.6 Force Defrost
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 31 In the extremely unlikely circumstance of the unit icing up (for example, if the unit was installed inside with no ventilation), this function can be applied.
When the unit is off, press and hold EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 for 10 seconds to enable the forced defrosting function. The defrosting symbol will light up. Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 for 10 seconds again to exit the forced defrosting function.

6.2.7 Fan/Ventilation Function
This function may come in useful if the system is installed inside and the fan settings need to be adjusted to suit ducting or external ventilation.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 31 The fan speed (High Speed, Low Speed or Off) can be controlled by the fan mode on the controller.
Fan mode symbols:
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 25 High Speed
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 36 Low speed
No Fan Icon: off
Note: When H02 is set to 0, there is no ventilation function.
Note: when the compressor is on, the fan will always run at high speed.EVOHEAT Evo270 1 Hot Water Heat Pump - Fan ModeWhen the parameter HO2 is set to 1, press the EVOHEAT Evo270 1 Hot Water Heat Pump - icon 14 for 2s.
Once you hear a beep you can set the ventilation mode. Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 14 for 2s, this will change the fan speed.
Continue to press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 14 for 2s until you reach your preferred speed.
6.2.8 System Date & Time
In the standby or running interface, press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 once, the hour digit will flash indicating it is being altered.
Press the EVOHEAT Evo270 1 Hot Water Heat Pump - icon 11 or EVOHEAT Evo270 1 Hot Water Heat Pump - icon 12 to change the hour setting, then press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 to confirm. Repeat this to change the minute value. EVOHEAT Evo270 1 Hot Water Heat Pump - System Date & Time6.2.9 Setting & Cancelling Timers
Timers can be set in standard mode, economic mode, auto mode & fast heating mode. They can be set by using buttons or using the touch timing circle. The unit will run during the lit time periods and stop in the dim areas.

Touch Method  Button Method 
• Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 13 and hold for 2 seconds (the timer display will flash)
• When the timer display flashes, choose yourstart-up time (A) and end time (B).
• Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 15 to save the setting and exit back to the main interface.
• Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 13 and hold for 2 seconds (the timer display will flash)
• When the timer display flashes, choose the start-up time (C) and end time (D) by pressing EVOHEAT Evo270 1 Hot Water Heat Pump - icon 11 or EVOHEAT Evo270 1 Hot Water Heat Pump - icon 12 and EVOHEAT Evo270 1 Hot Water Heat Pump - icon 13.
• Press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 15 to save the setting and exit back to the main interface.

Example: Setting the unit to run from 7-11am & 4pm-6pm using Touch mode. EVOHEAT Evo270 1 Hot Water Heat Pump - Cancelling TimersTo cancel a timer once it has been set, hold down the CLOCK EVOHEAT Evo270 1 Hot Water Heat Pump - icon 13 button for 2 seconds until the timer display begins flashing (as you would set the timer).
Press the POWER EVOHEAT Evo270 1 Hot Water Heat Pump - icon 10 button while the timer is flashing to cancel it. The yellow timing periods will disappear when the timer has been cancelled.

6.2.10 Vacation Mode
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 31 Vacation Mode allows you to turn the unit off to conserve power for an extended period of time, and restart operation on a date you specify. This ensures you have hot water waiting for you upon your return.
Ensure the unit is ‘OFF’ before setting vacation mode. The date you set in this mode will determine what date the unit starts back up.
After selecting vacation mode, press and hold EVOHEAT Evo270 1 Hot Water Heat Pump - icon 13 for 2 seconds, the ‘month’ value will begin to flash in the display area. Press the UP or DOWN arrows to display the desired month, then press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 13 to confirm and move to altering the ‘day’ value.
The ‘day’ value will flash when it is selected, use the arrow keys to select your desired start day, then press EVOHEAT Evo270 1 Hot Water Heat Pump - icon 13 to save all changes and exit back to the main interface.
Note: Format is mm/dd
Example: The unit will start up on September the 28th. EVOHEAT Evo270 1 Hot Water Heat Pump - September the 28th6.2.11 Sanitech System
The Sanitech feature’s purpose is to keep the water free of bacteria such as Legionella by heating the tank water to 70°C for one 30-minute period every week at midnight.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 31 An instance when you may want to alter the Sanitech function is if you have solar and would prefer the Sanitech to run during the day, for example at 12pm, rather than midnight.
If you would like to change this function, contact EvoHeat’s service department for guidance. Incorrectly attempting to adjust these settings yourself could significantly disrupt the unit’s operation.

Troubleshooting

Malfunction Fault Display Reason Elimination Methods
Bottom water temp. failure P01 The water bottom temp. sensor is open or short circuit. Check or change the water bottom temp. sensor
Top tank water temp.failure P02 The water top tank temp. sensor is open or short circuit Check or change the water top tank temp. sensor
Ambient temp. failure PO4 The ambient temp. sensor is open or short circuit Check or change the ambient temp. sensor
Coil temp. failure P05 The pipe temp. sensor is open or short circuit Check or change the pipe temp. sensor
Refrigerant absorb temp. failure P07 The evaporator temp. sensor is open or short circuit Check or change the evaporator temp. sensor
Anti-freeze temp. failure P09 The anti-freeze temp. sensor is open or short circuit Check or change the anti-freeze temp. sensor
Solar temp. failure P034 The solar temp sensor is open or short circuit Check or change the solar temp sensor
High pressure protection E01 The exhaust pressure is high, high pressure switch action Check high pressure switch and cooling return circuit
Low pressure protection E02 The suction pressure is low, low pressure switch action Check low pressure switch and cooling return circuit
Water flow failure E03 No water or little water in water system Water, check for flow volume pump failure
Electric-heater overheat protection E04 Water flow volume not enough, water system pressure difference is small Water, check if the flow volume system is jammed
Anti-freeze protection E05 Water flow volume not enough, water system pressure difference is small Water, check if the flow volume system is jammed
Communication failure E06 Wired remote control with master signal failure Check the connection line between the wired remote control and mother board
Winter defrost protection E07 Ambient temperature is too low

Appendix

8.1 Wiring Diagram EVOHEAT Evo270 1 Hot Water Heat Pump - Wiring Diagram8.2 Wi-Fi Module Connection (Optional)
Note: If you do not have a Wi-Fi module to install, simply push the cord entirely behind the front panel.
The optional Wi-fi Control upgrade can be purchased to allow you to remotely control your EvoHeat hot water heat pump from your phone.
Newly installed units will have a small cable that protruding out from behind the front panel with a small waterproof cover.
If you are installing the Wi-Fi module, simply connect the cable of the Wi-Fi module to the one that protrudes.
Once the Wi-Fi module has been connected, ensure that the connection part of the cable is placed behind the front cover.
The module must be placed with the cord coming downwards to protect it from water. EVOHEAT Evo270 1 Hot Water Heat Pump - Wi-Fi Module Connection8.3 Use of the P&T Valve
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 31 The P&T valve is used to prevent the temperature or pressure becoming too high inside the tank. When the temperature or pressure reaches the set value, the valve will open automatically to force the pressure or temperature to decrease
The handle of the safety valve should be tested once every six months to remove the calcium carbonate deposits and guarantee there is no blockage in the device. Take care to avoid burns as the temperature of the discharging water is very high.
Vent pipes should be thermally insulated to prevent safety risks caused by freezing pipes in winter.
P&T valve: Model: PTR-20, action temperature: 99˚C, action pressure:0.85MPa

EVOHEAT Evo270 1 Hot Water Heat Pump - icon 9 WARNING: Failing to operate the relief valve easing gear at least once every six months may result in the water heater exploding. Continuous leakage of water from the valve may indicate a problem with the water heater.

8.4 Using the Overheating Protector
The overheating protector is used to turn the power off in an emergency or with power supply issues, preventing the water from being heated too high.
A thermal cut-out could indicate a possibly dangerous situation. Do not reset the thermal cutout until the unit has been serviced by a qualified technician. Contact EvoHeat for a service if this occurs before attempting to reset.

EVOHEAT Evo270 1 Hot Water Heat Pump - Remove the screws and open the coverRemove the screws and open the cover

To return the unit to its normal operation status by resetting manually:
a) To access the overheat protector, remove the front dark grey controller panel.
b) Remove the 3 screws on the front panel and push the front cover upwards.
c) Remove the remaining screws which cover the overheat protector panel.

EVOHEAT Evo270 1 Hot Water Heat Pump - red buttonPress the red button to reset

8.5 Draining the Water Tank

  1. Close the cold-water inlet valve into the Evo270-1.
  2. Open a hot water tap inside the premises.
  3. Undo the drain plug on the base of the unit to drain the water from the system.

EVOHEAT Evo270 1 Hot Water Heat Pump - icon 9 The water from the hot water tap and the drain plug will be hot. Be careful of burns and scalds. Wear protective clothing.

8.6 Earthing Methodology EVOHEAT Evo270 1 Hot Water Heat Pump - Earthing Methodology

Maintenance

Your Evo270-1 will operate most efficiently if regularly inspected as part of your home maintenance schedule.
MINOR ANNUAL MAINTENANCE
It is recommended that the minor maintenance be performed every 12 months by the dwelling occupant.
The minor maintenance includes:

  • Operate the easing lever on the temperature pressure relief valve. It is very important you raise and lower the lever gently. Exercise care to avoid any splashing of water, as water discharged from the drain line will be hot. Stand clear of the drain lines point of discharge when operating the valve’s lever.
  • Operate the easing level on the expansion control valve (if fitted). It is very important you raise and lower the lever gently.
  • Conduct a visual inspection of all plumbing and electrical connections.
  • Check the condensate drain line to ensure it is not blocked.
  • Check that air vents are not blocked or obstructed, and if necessary clean with a damp cloth or air blower.
  • Conduct a general external clean of the unit with a damp cloth.

MAJOR FIVE-YEAR SERVICE
It is recommended a major five (5) year service be conducted on the Evo270-1.
EVOHEAT Evo270 1 Hot Water Heat Pump - icon 9 Warning: Servicing of a water heater must only be carried out by qualified EvoHeat personnel.
Phone EvoHeat Service on 1300 859 933 for our closest Accredited Service Agent.
Note: The five-year service and routine replacement of any components such as the anode and relief valve(s) are not included in the EvoHeat warranty. Only genuine replacement parts should be used on this water heater.
The major service includes the following actions:

  • Replace the temperature limiting valve.
  • Replace the temperature pressure relief valve.
  • Inspect the anode and if required, replace the anode. If the anode is not replaced, it should be replaced within three years of this service.
  • Check the heating cycle of the unit.
  • Visually check the unit for any potential problems.
  • Inspect the plumbing and electrical all connections.
  • Check the condensate on drain line to ensure it is not blocked.

Note: The water heater may need to be drained during this service. After the completion of the service, the water heater will take some time to reheat the water. Depending upon the power supply connect on, hot water may not be available until the next day.

Warranty

EVOHEAT Evo270 1 Hot Water Heat Pump - Symbol 2 Refer to the EvoHeat website for warranty details

  1. Warranty terms are from date of purchase.
  2. This warranty excludes any defect or injury caused by or resulting from misuse, abuse, neglect, accidental damage, improper voltage, vermin infestation, incompetent installation, any fault not attributable to faulty manufacture or parts, any modifications which affect the reliability or performance of the unit.
  3. This warranty does not cover the following:
    a. Natural Disasters (hail, lightening, flood, fire etc.)
    b. Rust or damage to paintwork caused by a corrosive atmosphere
    c. When serviced by an unauthorized person without the permission of Evo Industries
    d. When a unit is installed by an unqualified person
    e. Where a unit is incorrectly installed
    f. When failure occurs due to improper or faulty installation
    g. Failure due to improper maintenance (refer Operating Instructions)
    h. ‘No Fault Found’ service calls where the perceived problem is explained within the
    i. Costs associated with delivery, handling, freighting, or damage to the product in transit.
  4. If warranty service is required, you should:
    a. contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site
    b. provide a copy of your receipt as proof of purchase
    c. have completed the online Warranty Registration Form
  5. Onsite technical service is available within the normal operating area of your Evo Authorised Service Agents.
    Service outside this area will incur a traveling fee.
  6. Unless otherwise specified to the purchaser, the benefits conferred by this express warranty and additional to all other conditions, warranties, rights and remedies expressed or implied by the Trade Practices Act 1974 and similar consumer protection  provisions contained in legislation of the States and Territories and all other obligations and liabilities on the part of the manufacturer or supplier and nothing contained herein shall restrict or modify such rights, remedies, obligations or liabilities.

REGISTER YOUR WARRANTY

EvoHeat highly recommend customers complete their warranty details online to ensure efficient warranty claim processing.
To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/