EBECO EB-Therm 800 Ground Sensor User Manual
Thank you for choosing Ebeco and Ground sensor. The Ground sensor is adapted for use with thermostat EB-Therm 800. The thermostat settings for this application are given in this manual. If you need the complete manual for EB-Therm 800, you can download it to your smart phone by scanning the QR code or via the document archive at ebeco.com.
The product is covered by the warranty conditions and must be installed and used according to the manual. This applies to both the installer and the user of the product.
If you have any questions, please contact us at Ebeco. Call +46 31 707 75 50 or send an e-mail to [email protected]
Contents
Included in the package
- Ground sensor with 15 m cable
- Manual
- Wooden block 125x125x50 mm
Installation
Ground sensor installation
The location of the sensor is important for achieving correct and effective control of the snow melting system. The ground sensor is installed within a heated zone, but not under a roof. The exact position of the sensor is dependent on the system’s design and location.
The ground sensor’s upper surface must be even with the ground surface. NOTE: The ground sensor may never be above the ground surface.
The provided wooden block is positioned in the ground where the sensor is to be installed. A length of metal conduit (ø16 mm) is run to the wooden block for the connection cable. The metal conduit is temporarily sealed. Once the surface is covered with asphalt, concrete or similar material, the wooden block is removed and the sensor installed. The space between the sensor and surface covering is filled cement grout or similar material. The maximum permitted temperature for the fill is +80 °C.
Settings for EB-Therm 800
Sensor settings in the EB-Therm 800 thermostat. A complete manual for EB-Therm 800 is available for download from the document archive at ebeco.se.
Operation mode OPERATION MODE
The operation mode is selected on the start menu and cannot be changed after this menu is left. Scroll with or
and select MAX/MIN to use temp/moisture regulation. Confirm with
.
Sensor settings SENSOR
The thermostat uses moisture sensor C and temperature sensor A. The sensor settings are under SYSTEM MENU under SENSOR. Scroll with or
and select A:PÅ C:MOIST to use temp/moisture regulation. Confirm with
.
Delay +HEATING
The delay can be set to ensure that the entire installation is free of snow and ice before the thermostat is switched off. When the moisture sensor no longer detects moisture, the thermostat will remain active for the set time, before it switches off. The need for delay varies depending on the installation and the location of the sensor.
A delay of up to four hours can be set, in intervals of 30 minutes. The factory setting is zero.
Choose main menu
Browse with or
to system, confirm with
. Step to +HEATING and confirm. Browse with
or
to step up for each 0,5 hour to maximum 4 hours, confirm with
.
Technical data
- Connection voltage: 24 VDC
- Transient protection: Inbuilt
- Short circuit protection: Inbuilt
- Temperature sensor: NTC 10 kΩ at +25 °C
- Moisture sensor: Capacitive – output 24 VDC
- Circuit-breaking: capacity 200 mA / 24 VDC
- Connection cable: 15 m, 6×0,34 mm²
- Max. extension conn. cable: 50 m, 1,5 mm²
- Dimensions Foot: Ø 105, housing: Ø 70, tot. height: 50 mm
- Surrounding temperature: -25 °C to +70 °C
- Colour Black
- Protection class: IP67
- Approval CE
- Certification RoHS, WEEE
CERTIFICATIONS: RoHS
The ground sensor must be cleaned once yearly for optimal function. Clean using a little dishwashing detergent and a soft cloth.
Test values NTC sensor
0 °C | 27,5 kΩ |
5 °C | 22,2 kΩ |
10 °C | 18,0 kΩ |
15 °C | 14,7 kΩ |
20 °C | 2,1 kΩ |
20 °C | 10,0 kΩ |
Installation cable
Number | Colour | Function |
1 | e | Calibration |
2 | Brown | +24 VDC |
3 | Green | -24 VDC |
4 | Yellow | NTC temperature |
5 | White | Moisture output 24 |
VDC | ||
6 | Pink | NTC temperature |