Charge Amps Aura
User Manual
www.chargeamps.com
Contents
Aura Dual EV Charger
Respect the environment! Must not be discarded with household waste! This product contains electrical or electronic components. Leave the product for separate collection and proper treatment at a designated location e.g. the local authority’s recycling station.
In conformity with the relevant EU directives.
Neglecting to follow and carry out the directions, instructions and safety precautions in this User Manual implies that any warranty provisions will be cancelled and that Charge Amps can reject any and all claims for compensation in connection with any injuries/damage or incidents direct or indirect that are a result of such negligence. Charge Amps AB does not give any warranties as to the accuracy or completeness of this document and shall have no liability for the consequences of using such information. Charge Amps AB reserves the right to make changes to information published in this document without notice.
Visit www.chargeamps.com for the latest document releases.
© Copyright Charge Amps AB. All rights reserved. Copying, amending and translating are strictly forbidden without prior written approval from Charge Amps AB.
Safety
WARNING! Read all instructions before installation.
- Improper use may create a risk of personal injury.
- The product must only be installed or opened by a qualified electrician in accordance with the Installation Manual.
- National usage requirements and restrictions apply.
- Only use this product for charging compatible electric vehicles.
- Never use an adapter between the EV socket-outlet and the charging cable.
- Cord extension sets are not allowed to be used.
- Inspect the product for visible damage before use.
- Never attempt to repair or use the product if it is damaged.
- Do not immerse the product in water, subject it to physical abuse or insert foreign objects in any part of the product.
- Never attempt to disassemble the product in any way.
- The owner is responsible for informing users of the compatibility of any charging point.
Technical data
Charging mode | Mode 3 |
EV power supply identifier | ![]() |
Metering | 1 to 3 phase voltage, current and power |
Socket | Type 2, up to 2×22 kW |
Rated voltage (Un) | 230/400 V |
Rated insulation voltage (Ui) | 250/400 V |
Rated impulse withstand voltage (Uimp) | 4 kV |
Rated frequency (fn) | 50 Hz |
Rated current (In) | 63 A |
Rated diversity factor (RDF) | 1 (can be lowered if used together with a load balancing functionality) |
Dimensions (W x D x H) | 367 x 159 x 405 mm |
Characteristics of power supply and output | AC EV supply equipment connected to AC supply network, permanently connected. |
Assembly type | AECVS |
RFID | Type: ISO/IEC 14443 Typ A 13.56MHz Mifare Range: 13.553 – 13.567 MHz Output: 31 dBm |
Wi-Fi | Type: 802.11 b/g/n Range: 2400 – 2500 MHz Max output: 20/17/14 [email protected] b/g/n |
Cellular networks communication (only applies to Charge Amps Aura with product number 130908 and 101010-LTE). |
Type: GSM, GPRS, EDGE, UMTS/ HSPA+, LTE Range: 698 – 960 / 1710 – 2690 MHz Max. output: 33 dBm@GSM, 24 dBm@ WCDMA, 23 dBm@LTE SIM Card: Standard SIM (25mm x 15mm). |
Product overview
A RFID reader B RFID light C EV socket-outlet |
D Socket light E Cylinder light |
Package contents
- Charge Amps Aura
- Accessories:
• Cable slide
• Cable fitting for power (M32): 13 – 17.5 mm and 17 – 25 mm
• Cable fitting for data (M12): 4 – 8 mm
• Plugs for non-used cable entries
• M32 insert only
• Screws
• 2x RFID tags
• 2x Cylinder lock keys
• Wago jumper for IT network connection (MPN: 2016-433)
Additional contents:
- Document with serial number and password
- Quick Guide User
Use
Add RFID tag
N.B. Make sure your installer has given you the access to Charge Amps Admin Portal to be able to manage RFID tags.
Add RFID tag using the Charge Amps cloud service: https://my.charge.space/admin
Start and stop charging without RFID identification
- Initiate charging by connecting the EV connector to the car. Lift the EV socket lid and connect the EV plug to the EV socketoutlet.
- Stop charging by disconnecting the EV connector from the car and disconnect the EV plug from the EV socket-outlet.
Start and stop charging with RFID identification
- Initiate charging by connecting the EV connector to the car. Lift the EV socket lid and connect the EV plug to the EV socketoutlet.
- Briefly hold the RFID tag in front of the RFID reader to initiate charging.
N.B: If the other EV socket-outlet is not in use, it will turn dark and be unavailable for 5 minutes during the verification of the RFID tag. If no RFID tag has been verified during these 5 minutes, charging needs to be initiated remotely or reactivated by unplugging and reconnecting the vehicle connector. - Stop charging by disconnecting the EV connector from the car and disconnect the EV plug from the EV socket.
Cable lock
During charging, the cable lock on the charging station is automatically activated.
To permanently lock the EV charging cable to Charge Amps Aura while not charging, use Charge Amps App or cloud.
Cloud connectivity
Charge Amps Cloud and Charge Amps App are available for Charge
Amps Aura connected to Charge Amps as the cloud provider.
Charge Amps App
Please download Charge Amps App for full control, adjusting settings and enabling smart charging and scheduling.
![]() |
![]() |
https://play.google.com/store/apps/details?id=com.chargeamps.app&gl=SE |
Charge Amps Cloud
Please create an account in the Charge Amps Cloud to configure, control and manage your charger via our web interface.
Full product information
Visit www.chargeamps.com for Charge Amps Aura Installation Manual, Charge Amps Aura User Manual and other product documentation.
https://www.chargeamps.com/product/charge-amps-aura/
11
LED indications
General
Status | Socket light | RFID light |
Ready for charging | Green light | – |
Charging | Blue light | – |
Charging complete (paused by vehicle) | Yellow light | – |
Charging paused (paused by Aura) | Flashing blue light/yellow steady light* | – |
* Depending on version
RFID tag verification
Status | Socket light | RFID light |
Waiting for RFID verification | Yellow light | Flashing blue light |
RFID tag not approved | Yellow light | Red light* |
RFID tag approved | Green lights up |
* Auto-return to ”Waiting for RFID verification”
Other
Status | Socket light | RFID light |
EV socket-outlet not available for use | No light | No light |
Error | Red light | No light |
Maintenance
Regular maintenance
N.B: Never spray water or any other liquid directly on to the product.
- Visually check that the EV socket-outlet it free from damage.
- The outside of the product must be regularly wiped with a clean, dry cloth to remove dirt and dust.
- Do not use detergent to clean any of the product’s components.
Preventative maintenance
N.B: Preventative maintenance should be performed by a qualified electrician once or twice each year to check that Charge Amps Aura is in good condition.
- Remove the front cover and make a visual check of the cable connections.
- Gently rock the internal RCBO to make sure it’s properly seated.
Product support and service
If you have any questions or problems with the product, support is always available. To find answers to your questions most quickly: Read through this User Manual to check whether your questions are answered here.
If your question is not answered in the User Manual, please:
- Contact your supplier or cloud provider.
- If you need service or repair, start by contacting the supplier from whom you purchased the product.
- For additional information, visit our Help Center at: www.chargeamps.com/support.
Warranty
Warranty terms may differ from market to market. Contact your supplier regarding the warranty terms.
Charge Amps AB (publ)
Frösundaleden 2B, 8th floor SE–169 75 Solna, Sweden
Charge Amps UK Ltd
4th Floor, 3 More London Riverside London SE1 2AQ, United Kingdom
Doc. Nr: 130629
Rev: 02