cell2 B18-DC Dual Colour LED Beacon User Manual

Home » Cell2 » cell2 B18-DC Dual Colour LED Beacon User Manual

Cell2 logo

B18-DC Dual Colour LED Beacon User Manual

WIRING / OPERATION

Permanent Mount:

BLACK: To -Chassis Ground
RED: To +VDC (fuse@5A) for Warning Mode in COLOUR1
YELLOW: To +VDC (fuse@5A) for Warning Mode in COLOUR2
 (RED + YELLOW):  To +VDC (fuse@5A) for Warning Mode in COLOUR1 alt. 2
 WHITE: [+] for Low Power Operation Activate dimming function by continuously applying +VDC to WHITE wire.

Magnetic Mount:
NOTE: Magnetic Mount model does not feature Low Power dimming function.
BUTTON 1 – Maintained Switch:
Position 1 – ON (Warning Mode in COLOUR1)
Position 2 – OFF
BUTTON 2 – Momentary Switch:
Press 1- Warning Mode in COLOUR2.
Press 1 again – Warning Mode in COLOUR1 alt. 2
Press quick 3 times – Warning Mode in COLOUR1

FLASH PATTERNS
1 Double [R65]
2 Single [2HZ]
3 Triple [2HZ]
4 Quad [2HZ]
5 Random
6 Steady
7 Single [SAE, CA13]
8 Double [SAE]
9 Triple [SAE]
10 Quad [SAE]
11 Quint [SAE]
12 Mega
13 Ultra [SAE]
14 Single-Quad
15 Single H/L
16 Single-Triple-Quint

Note: i. This unit may not be factory-set at FP#1
ii. Actual approval base on the model ordered.

FLASH PATTERN SELECTION

cell2 B18-DC Dual Colour LED Beacon

  1. Open
    Twist the dome lens counter clockwise A , then lift the dome lens to open.
  2. Change
    While activating Warning Mode, momentarily push the RED BUTTON B to change to the next flash pattern. (see Flash Patterns Chart)
    cell2 B18-DC Dual Colour LED Beacon - Fig 1Note: All COLOUR1, COLOUR2 and COLOUR1 alt. 2 warning modes may select different Flash Pattern.
  3. Close
    Twist and tighten the dome lens clockwise C to close.

cell2 B18-DC Dual Colour LED Beacon - Fig 2