24VDC 6-Led Narrow Profile Lighthead
Installation Guide
Contents
12-24VDC 6-Led Narrow Profile Lighthead
Wiring / Operation Connect YELLOW wires of all heads together for synchronization. (All heads should be set to the same pattern)
For Simultaneous or Alternating Flash:
- Apply +VDC to RED and YELLOW wires simultaneously to enter
Grouping mode; lighthead will display short (single or double) flashes: Single flash = Group1 Double flash = Group2 - Remove YELLOW wire from +VDC and momentarily apply to +VDC to change Groups:
Heads in the same Group flash together. Group1 heads alternate with Group2 heads.
For Flash Patterns:
Momentarily apply +VDC to
YELLOW wire:
- once for next pattern
- quick three times to reset to FP#1
NOTE:
- This unit may not be factory-set at FP#1.
- Please double check lighthead orientation before mounting for FP# 22.
Flash Patterns | |||
1 | Double [R65] | 13 | Single H/L (split) |
2 | Single [2Hz] | 14 | Single [SAE] |
3 | Triple [2Hz] | 15 | Double [SAE] |
4 | Quad [2Hz] | 16 | Quad [SAE] |
5 | Random | 17 | Quint [SAE] |
6 | Single (split) | 18 | Mega |
7 | Double (split) | 19 | Ultra [SAE] |
8 | Quad (split) | 20 | Single-Quad |
9 | Quint (split) | 21 | Single H/L |
10 | Mega (split) | 22 | Steady Half |
11 | Ultra (split) | 23 | Steady All |
12 | Single-Quad (split) |
*split = Left alternating Right
Installation
Universal Bracket (Multi-Angle)NOTE: Please mount the lighthead according to the mounting style puchased.
- Graphs only show horizontal illustration.
L-Bracket (Front / Rear)