Product overview

The Smart Control Unit include of three parts which are water meter, smart valve, IoTunit. Easyfor customer bulk meter valve control purpose.

Technical Specification

Completer meter
Manufacturer Bove
Dimension
DN (mm) Length Height Width D Bolt (flange) End Connection
50 308 410 165 125 4*M16

 

65 312 430 182 145 4*M16

 

80 339 452 197 160 8*M16

 

100 357 475 218 180 8*M16

 

125 390 503 245 210 8*M16

 

150 440 540 283 240 8*M20

 

200 502 582 335 295 12*M20

 

250 615 720 405 355 12*M24

 

300 678 790 460 410 12*M24

 

350 690 853 520 470 16*M24

 

400 716 964 580 525 16*M27

 

Flow Measurement
DN (mm) Flow Rate (m3/h) @R500
Q3 Q2 Q1

 

50 25 0.08 0.05

 

65 40 0.128 0.08

 

80 63 0.2016 0.126

 

100 100 0.315 0.2

 

125 160 0.512 0.32

 

150 250 0.8 0.5

 

200 400 1.28 0.8

 

250 630 2.016 1.26

 

300 1000 3.2 2

 

350 1000 3.2 2

 

400 1600 5.12 3.2

 

Pressure Loss △P ≤40KPa
MAP 1.6MPa
Water temperature range (Optional) 0.1-30°C(T30)/0.1-50°C(T50)
Q3/Q1 (optional) R160/R200/R250
Accuracy Class2
Maximum permissible error in upper flow rates range Q2 £ Q £ Q4 ±2%(at Temperature≤30°C)
±3%(at Temperature>30°C)
Maximum permissible error in lower flow rates range Q1 £ Q < Q2 ±5%
Scale interval (m3) 0.001
Capacity of calculator 99999,999
Type of liquid Drink Water
Installation requirements Min.5*DN length of straight pipe before the meter, and Min.3*DN length of straight pipe after the meter (DN is the diameter of meter)
Basic mounting  orientation and other specified orientations Horizontal/Vertical
Display & Indication
Display unit (Optional) m3/L/Gal
Display LCD 8-digit
Volume 0.001m³
Time to LCD off Always on
Environmental Requirement
Environmental Class E1,M1
Ambient temperature 5~55°C(Indo or and non-condensing)
Storage temperature -20~60°C
Protection Class (Optional) IP68
Data history (Optional) 24/120logs,daily/weekly/monthly
Interface & Communication
Output signal for normal operation (Optional) Wire communication
RS485/M-Bus
Wire less communication
LoRa WAN/ NB-IoT/ Sigfox
Output display/signal for testing (Optional) M-Bus,RS485,Infrared
Power Supply
Battery Lithium Battery
Battery Life (Optional) 6Years/10Years/16Years
24V DC (Optional) External supply for special version
Mechanical Specification
Meter Body Cast Iron
Valve part
Working temperature -30 to 210℃
Power DC12V/ External power (optional)
Pressure PN16
Connection Flange
Water protect IP68
Size DN50-400

Valve part

Customer Support

Copyright© 2023 Bove Intelligent Technology Co., Ltd

Bove Intelligent Technology Co., Ltd

Add: Level 5, Building 5, No. 36,
Changsheng South Road, Jiaxing,
Zhejiang, China, 314000
Tel: +86 573 83525916
Fax: +86 573 83525912
Email: [email protected]
www.bovetech.com

Logo

Leave a Comment