BEISIT F20H UHF RFID Reader User Manual

Home » BEISIT » BEISIT F20H UHF RFID Reader User Manual

BEISIT F20H UHF RFID Reader

BEISIT F20H UHF RFID Reader

  • Product Name:UHF RFID Reader
  • Product Model:FBUR-F20H-S01

Product Appearance

Product Appearance

Hardware Functionality

Product Features

UHF RFID dual-channel industrial-grade reader with high protection level and high performance, possessing strong anti-interference capability. It adopts an industrial connector design and is enclosed in a full aluminum alloy shell, making it suitable for various industrial application scenarios.

Basic Parameters

RFID Protocol EPC C1G2/ISO 18000-6C Sensitivity -86dBm
Maximum Power 33dBm Read Rate >800张/s
Frequency 860~960Mhz Read Range >15m(Relating to Antennas and Tags)
Power supply DC9~36V Dimensions 127(L)*109(W)*38(H)mm
Weight <600g Storage Temperature -40~+85℃
Operating Temperature -40~+70℃ Environmental Humidity 5%~95%rh

Interface

 Power Interface M12-4P-A-Female Communication Interface M12-4P-D-Female(LAN)
M12- 8P-A-Male(RS232、RS485)
RF Interface 2个TNC,External Thread and Internal Pin

Indicator light

Power light Icon Green light (always on when powered, indicating normal operation)
Signal light Icon upgrading, it flashes once every 1 second; there is a fault, it flashes twice every 1 second.
Network light Icon Green light (remains constantly on when the network connection is successful)
Network data light Icon Yellow light (flashes during network data transmission)
Antenna light Icon Blue light (remains constantly on after antenna setup, flashes when reading tag data)

Certification

Certification SRRC、CE、FCC、ROHS、IP

Software Functionality

Support Agreement

IECISO EPC C1G2/ISO 18000-6C 、ISO 18000-6B(Optional equipment)

Support for Other Features

  • Support online firmware burning and upgrading
  • Support multiple communication protocols and interfaces
  • Support standard functions of air interface protocol: read, write, lock, kill, etc.
  • Support various data upload modes including EPC+TID, EPC+USER, EPC+RFU, EPC+TID+USER, EPC+TID+RFU
  • Support various tag reading modes for different scenarios: multi-tag group reading, single-tag long-rang reading, adaptive reading, low-power mode
  • Support power setting: 5~28dBm, adjustable in 1dBm steps
  • Support working frequency band setting for each region, customizable frequency band or frequency point setting
  • Support tag return of RSSI, carrier, and phase
  • Support over-temperature protection with temperature accuracy of 0.5 degrees
  • Support setting of working time and interval time for each antenna
  • Support BLF parameter link setting for strong group reading performance
  • Support filtering tag operations, support network heartbeat packets, support CW wave switch, Session value setting, Q value setting
  • Support software and hardware watchdog
  • Support remote restoration of factory settings.

Interface Definition

Power

Working power supply Type 1

Device M12-4PIN-A Male

Interface Definition P1 VIN
P2 VIN
P3 GND
P4 GND
Working power supply Type 2

Device M12-4PIN-A Female

Interface Definition P1 VIN
P2 VIN
P3 GND
P4 GND

Communication

Ethernet
Device M12-4PIN-D Female
Interface Definition P1 TX+
P2 RX+
P3 RX-
P4 TX-
Com
DeviceM12-8PIN-A Male
Interface Definition P8 NC
P7 NC
P6 RS232-RX
P5 RS232-TX
P4 RS485-B
P3 RS485-A
P2 GND
P1 VIN

Other Parameters

Product Dimensions
Product Dimensions

Symbol FCC Warning

 FCC Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

TEL: +0086-571-8936 2888
E-MAIL:[email protected]
https://www.beisit.cn
Logo