BEGA 50840.2 Wall Luminaire for Indoor Use Instruction Manual
Contents
Instructions for use
Application
Free-radiating wall luminaire · indoor luminaire with crystal glass, white inside and aluminium housing. For all lighting tasks in interior applications.
They are ideal for places where a soft and uniform lighting distribution is required.
Product description
Luminaire made of aluminium alloy Finish Stainless steel Crystal glass, inside white, with bayonet closure 2 mounting holes ø 4.5mm Distance apart 35mm 1 cable entry for mains supply cable up to ø 10.5 mm max. 3 x 1.5@ Connecting terminals 2.5@ Earth conductor connection LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components Safety class I Impact strength IK05
Protection against mechanical impacts < 0.7 joule
Safety mark
Conformity mark
Weight: 2.0 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 9.6 W |
Luminaire connected wattage | 11.3 W |
Rated temperature | ta=25 °C |
Ambient temperature | ta max=50 °C |
50 840.2K3
Module designation | 2x LED-0689/930 |
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 1560 lm |
Luminaire luminous flux | 928 lm |
Luminaire luminous efficiency | 82,1 lm/W |
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo the hexagon socket head screw (wrench size 5mm) and remove mounting plate from luminaire housing.
Loosen earth connection (plug connection) between luminaire housing and mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Make earth connection to earth screw and electrical connection to the terminals.
Make earth connection (plug connection) between luminaire housing and mounting plate again.
Place connecting terminals inside the luminaire housing.
Install luminaire housing onto the mounting plate, adjust and tighten hexagon socket head screw.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to thoseof the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Please follow the installation instructions for the LED module.
Screw in glass by turning it clockwise. Defective glass must be replaced.
Spares
LED power supply unit DEV-0136/350
LED module 3000 K LED-0689/930
Spare glass 75 003 649