37700 House Number Luminaire
Instructions for use
Application
House number luminaire with weatherproof lettering for one or two digits or letters. A luminiaire which allows numbers and details to be recognized by day and night.
Lamp | |
Luminaire connected wattage | 10 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
37 700 K3 | |
Module designation | LED-0607/830 |
Colour temperature | 3000 K |
Colour rendering index | Ra > 80 |
Module luminous flux | 1080 lm |
Luminaire luminous flux | 676 lm |
Luminaire luminous efficiency | 67,6 lm / W |
Product description
Luminaire made of aluminium alloy and stainless steel BEGA Unidure® coating technology Opal glass with 1 or 2 numbers Lettering height 120 mm 2 mounting holes ø 6 mm Distance apart 110 mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm 4 prefabricated cable ducts for surface mounted mains supply cables Connection terminal 2.5@ Earth conductor connection LED-Module for mains voltage 220-230 V 50/60 Hz BEGA Thermal Switch® Temporary thermal shutdown to protect temperature-sensitive components Safety class I Protection class IP 44 Protected against granular foreign bodies ≥ 1 mm and splash water Impact strength IK03 Protection against mechanical impacts < 0.35 joule
– Safety mark
– Conformity mark
Weight: 1.2 kg
This product contains light sources of energy efficiency classes F.
Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
Snap the opal glass into the lower spring clips,
centralise and push into the upper spring clips.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified electrician or a comparably qualified person using standard tools.
Disconnect the electrical installation.
Pull glass out of the spring clips and remove from the luminaire back housing.
Clean the glass and luminaire housing using only suitable cleansers.
When cleaning please do not use high pressure cleaners.
Please follow the installation instructions for the LED module.
A broken glass must be replaced.
Snap the glass into the lower spring clips, centralise and push into the upper spring clips.
When ordering spare glasses please advise figures or symbols.
Spares | |
Spare glass | 11 002 057 .0 |
LED module 3000 K | LED-0607/830 |
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
[email protected]