AURA LIGHT Sevede RE RAMP Instruction Manual

Home » AURA LIGHT » AURA LIGHT Sevede RE RAMP Instruction Manual

AURA LIGHT Sevede RE RAMP 

AURA LIGHT Sevede RE RAMP

INSTALLATION INSTRUCTIONS

  1. Prepare luminaires.
    Installation Instruction
  2. Move joint bracket to exact position. Secure with screws.
    Installation Instruction
  3. a: Mount “Sevede RE Start” according to the manual for standard Sevede RE.
    Installation Instruction
    b: Mount “Sevede RE Mid” or “Sevede RE End”.
    Installation Instruction
    c: Mount “Sevede RE End”.
    Installation Instruction
  4. Join luminaires mechanically with metal excenter lock. Connect the cable to terminal block.
    Installation Instruction
  5. a: Cross section visualization. Attach inner profiles.
    Installation Instruction
    b: Keep inside cables away when mounting inner profile!
    Installation Instruction
  6. After installation; move optics to centre, without any light gaps. Place “light traps” at each end. Applicable for opal and micro prismatic versions.
    Installation Instruction

Symbols
Note:
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

Basic insulation between supply- and control-terminals (DALI).

Symbol If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

CUSTOMERS SUPPORT

Aura Light AB, Sweden
Phone customer service +46 (0)20 32 30 30
[email protected], www.auralight.com

Logo