Wiring Connection Instructions:

Positive Output Terminal: Must be connected via
properly sized cable to the battery or batteries being charged.
Cable size is determined by alternator output & length of cable
run.

Ground Terminal: Must be connected via properly
sized cable to the main ground point or batteries being charged.
*Note* Support ground post with a 1/2 wrench when tightening or
loosening the nut.

ARCO Zeus IE (Internal/External) Alternator Wiring Connection
Instructions:

Internal/External (IE):

  • A Grey Wire (Stator Output)
  • B Blue Wire (Field)
  • C White Wire (Ignition Wire)

Connect to Tach Input. Connect to External Regulator field wire.
Only used when using internal regulator connected to keyed on power
source.

D Red Wire (Sense Wire): Connect to B+ post or
dedicated Battery sense wire.

External Regulator (EX):

  • A Grey Wire (Stator Output)
  • B Blue Wire (Field)

Connect to Tach Input. Connect to External Regulator field
wire.

FAQ

Q: Where should the Positive Output Terminal be connected?

A: The Positive Output Terminal must be connected via properly
sized cable to the battery or batteries being charged.

Q: How should the Ground Terminal be connected?

A: The Ground Terminal must be connected via properly sized
cable to the main ground point or batteries being charged. Support
ground post with a 1/2 wrench when tightening or loosening the
nut.

Q: What is the Red Wire (Sense Wire) used for?

A: The Red Wire (Sense Wire) should be connected to the B+ post
or a dedicated Battery sense wire.

“`

ARCO Zeus
High output alternator
Wiring Connection Instructions

ARCO Zeus High output alternator
Wiring Connection Instructions
Positive Output Terminal
Must be connected via properly sized cable to the battery or batteries being charged. Cable size is determined by alternator output & length of cable run.
Ground Terminal
Must be connected via properly sized cable to the main ground point or batteries being charged. *Note* Support ground post with a 1/2″ wrench when tightening or loosening the nut.
ARCO Zeus IE (Internal/External) Alternator
ARCO Zeus IE (Internal/External) alternators are designed and recommended for use with our Zeus high energy Bluetooth alternator regulator, the Zeus IE Alternator utilizes both an Internal regulator and a field wire connection. If battery loads are relatively small and your engine is running frequently, the alternator’s internal regulator may be sufficient to support your electrical needs without external regulation. If your vessel utilizes larger battery banks or the engine’s duty cycle is less frequent, the Zeus IE Alternator combines and works seamlessly with ARCO Zeus high energy Bluetooth alternator regulator. *Note* The waterproof male connector with pins is included in a bag within the alternator box. This can be pinned out to connect your system wiring to the alternator for a waterproof connection. *If you are not sufficiently experienced with charging system upgrades, we recommend consulting with a certified technician prior to installation.

HIGH OUTPUT ALTERNATOR
Complete Wiring Guide

Internal/External (IE)

A Grey Wire (Stator Output) B Blue Wire (Field) C White Wire (Ignition Wire)

Connect to Tach Input.
Connect to External Regulator field wire.
Only used when using internal regulator connected to keyed on power source.

D Red Wire (Sense Wire)

Connect to B+ post or dedicated Battery sense wire.

External Regulator (EX)

A Grey Wire (Stator Output) B Blue Wire (Field)

Connect to Tach Input. Connect to External Regulator field wire.

ABCD

INTERNAL / EXTERNAL

B+

POSITIVE BUS BAR

ALTERNATOR GROUND
AB

NEGATIVE BUS BAR
EXTERNAL

MAIN GROUND BATTERY

B+

POSITIVE BUS BAR

MAIN GROUND

ALTERNATOR GROUND

NEGATIVE BUS BAR

BATTERY

arcomarine.com

Toll Free: 1-800-722-2720

3921 W. Navy Blvd. Pensacola, FL 32507 Fax: 850-453-2630

2