AR RMW Hollow Shaft Pump User Manual

Home » AR » AR RMW Hollow Shaft Pump User Manual

AR-LOGO

AR RMW Hollow Shaft Pump

AR-RMW-Hollow-Shaft-Pump-product

  • 140° F – Max Water Temp
  • 3/4” GHA – Inlet Thread
  • 22mm x 14 M – Discharge Thread
  • 2.2 oz – Oil Capacity

AR-RMW-Hollow-Shaft-Pump-fig-1

OVERVIEW

AR-RMW-Hollow-Shaft-Pump-fig-2

Note

  • SX Style – left-handed pumps have a hole in the leg opposite of the unloader.
  • Non-SX Style – Right-handed pumps have a hole in the leg on the same side as the unloader.

DIMENSION

AR-RMW-Hollow-Shaft-Pump-fig-3AR-RMW-Hollow-Shaft-Pump-fig-4

SPECIAL PARTS / KITS

MOD DESCRIPTION LIST PRICE
AR43061 Complete Manifold – aluminum $177.79
AR42142 EZ start kit $11.34
AR42165 Inlet – with o-ring $27.86
AR42166 Outlet – with o-ring $13.09
AR42141 Grub screw and washer $4.72
AR42125 Chemical injection kit $8.96
AR46377 Complete Manifold RMW25G28 $379.06
AR64545 Oil (4.5 oz) $15.47

REPAIR KITS

AR-RMW-Hollow-Shaft-Pump-fig-5

Product Specifications

  • Model: RMW
  • Type: Hollow Shaft Pump
  • Material: Aluminum Brass
  • Thermal Relief Valve: Included
  • Easy Start Valve: Included
  • Max Flow Rate: 193 l/min (51 gpm)
  • Max Pressure: 12 bar (174 psi)
  • Bore Diameter: 12 mm
  • Stroke: 12 mm
  • Crankshaft ID Stamp: Yes

Product Usage Instructions

Installation

  1. Ensure the pump is securely mounted on a stable surface.
  2. Connect the necessary hoses to the inlet and outlet ports of the pump.
  3. Prime the pump by filling it with water before operation.
  4. Check all connections for leaks before starting the pump.

Maintenance

  1. Regularly check and clean the inlet and outlet ports.
  2. Monitor the oil level and top up if necessary.
  3. Inspect and replace any worn-out seals or O-rings as needed.

Troubleshooting

  1. If the pump fails to start, check the power source and connections.
  2. If there is a drop in performance, inspect and clean the valves and pistons.

Frequently Asked Questions (FAQ)

Q: How often should I change the oil in the pump?
A: It is recommended to change the oil every 3 months or after every 50 hours of operation, whichever comes first.

Q: What should I do if the thermal relief valve activates frequently?
A: Check for any obstructions in the system that may be causing excessive pressure buildup. Also, ensure the pump is not running dry.

Leave a Comment