AcuityBrands P6300 Juno Trac Adapter Installation Guide
WARNING Read all of these installation instructions before installing.
SAVE THESE INSTRUCTIONS
Contents
FIXTURE INSTALLATION
Step 1 Find the latch and the polarity line. Align parts as shown and insert the adapter box into the track. (Fig. 1)
Step 2 Pull down the latch while rotating the adapter box 90 degrees clockwise. (Fig. 2)
Step 3 Final Position: Latch snaps into place between extrusion rails. Arrows on latch point toward the polarity line. (Fig. 3)
SECOND CIRCUIT POSITIONING
Step 1 Raise the contact marked “P” (on switch side) by inserting a thin screwdriver blade under contact. Pull up into position as shown. (Fig. 4)
Step 2 Insert contact support (supplied with 2-circuit Trac section) by tilting and snapping into position under the “P” contact as shown. (Fig. 5)
Step 3 Ensure contact support is snapped and locked into position. (Fig. 6) Follow instructions for inserting into track.
TROUBLESHOOTING
Problem | Cause | Remedy |
Fixture doesn’t turn on | Track not energized | Ensure track has power |
Adapter switch is in the “Off” position | Ensure the power switch on the track fixture adapter is in the “On” position, see Fig. 9![]() |
|
Ensure fixture is installed correctly, with the arrows on the latch pointing towards the polarity line as shown in Fig, 3 | ||
Fixture installed incorrectly | Ensure contacts aren’t bent from installing the fixture incorrectly, see Fig. 7![]() |
|
“P” Contact adjusted incorrectly | Ensure “P” contact isn’t bent from adjusting incorrectly, see Fig. 8![]() |
|
Bent contact from adjusting the wrong contact, see Fig. 4, 5, & 6 for proper adjustment method |
ne Lithonia Way Conyers, GA 30012 1-800-705-SERV (7378) www.acuitybrands.com ©2020 Acuity Brands Lighting, Inc. P6300 Rev 10/2022