WARNING Read all of these installation instructions before installing.

SAVE THESE INSTRUCTIONS 

FIXTURE INSTALLATION

Step 1 Find the latch and the polarity line. Align parts as shown and insert the adapter box into the track. (Fig. 1)
Fixture Installation

Step 2 Pull down the latch while rotating the adapter box 90 degrees clockwise. (Fig. 2)
Fixture Installation

Step 3 Final Position: Latch snaps into place between extrusion rails. Arrows on latch point toward the polarity line. (Fig. 3)
Fixture Installation

SECOND CIRCUIT POSITIONING

Step 1 Raise the contact marked “P” (on switch side) by inserting a thin screwdriver blade under contact. Pull up into position as shown. (Fig. 4)
Second Circuit positioning

Step 2 Insert contact support (supplied with 2-circuit Trac section) by tilting and snapping into position under the “P” contact as shown. (Fig. 5)
Second Circuit positioning

Step 3 Ensure contact support is snapped and locked into position. (Fig. 6) Follow instructions for inserting into track.
Second Circuit positioning

*Juno Trac adapter size and style may vary.

TROUBLESHOOTING

Problem Cause Remedy
Fixture doesn’t turn on Track not energized Ensure track has power
Adapter switch is in the “Off” position Ensure the power switch on the track fixture adapter is in the “On” position, see Fig. 9
Second Circuit positioning
Ensure fixture is installed correctly, with the arrows on the latch pointing towards the polarity line as shown in Fig, 3
Fixture installed incorrectly Ensure contacts aren’t bent from installing the fixture incorrectly, see Fig. 7
Second Circuit positioning
“P” Contact adjusted incorrectly Ensure “P” contact isn’t bent from adjusting incorrectly, see Fig. 8
Second Circuit positioning
Bent contact from adjusting the wrong contact, see Fig. 4, 5, & 6 for proper adjustment method