MEAN WELL RPS-60 Series Reliable Green Medical Power Supply Owner’s Manual

Home » MEAN WELL » MEAN WELL RPS-60 Series Reliable Green Medical Power Supply Owner’s Manual

MEAN-WELL-LOGO

MEAN WELL RPS-60 Series Reliable Green Medical Power Supply

MEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-PRODUCT

Product Information

  • Specifications:
    • Model: RPS-60 series
    • Power Output: 60W
    • Compliance: EN 60601-1, IEC 60601-1, ANSI/AAMI ES60601-1, BS EN/EN60601-1, IEC60601-1, UL62368-1, BS EN/EN62368-1, IEC62368-1
    • Model Number: TPTC004

Product Usage Instructions

  • Power Supply Connection:
    • Ensure the power supply is compatible with your device’s input requirements. Connect the power supply to a suitable power outlet.
  • Device Connection:
    • Connect the output of the power supply to your medical device following the manufacturer’s guidelines.
  • Power On:
    • After making all necessary connections, switch on the power supply using the provided power button.
  • Monitoring:
    • Monitor the power supply to ensure it is functioning correctly and providing the required power output to your device.
  • Safety Precautions:
    • Always follow the safety guidelines provided in the user manual to prevent any accidents or damage to the equipment.

FAQs

  • Q: Is the RPS-60 series power supply suitable for continuous use in medical applications?
    • A: Yes, the RPS-60 series power supply is designed for reliable and continuous use in medical applications while meeting safety standards.
  • Q: Can I use the power supply with devices that have different power requirements?
    • A: It is essential to match the power supply output with your device’s input requirements to prevent damage. Consult the device manufacturer for compatibility.

Features

  • 4″x2″ compact size
  • IT & Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1, IEC/BS EN/EN60601-1, and lEC/BS EN/EN/UL 62368-1
  • Suitable for BF application with appropriate system consideration
  • Cooling by free air convection
  • EMI Class B for class I configuration
  • No load power consumption<0.75W
  • Protections: Short circuit / Overload / Over voltage
  • Operating altitude up to 3000 meters
  • 3 years warrantyMEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-FIG-1 (1)

Applications

  • Oral irrigator
  • Hemodialysis machine
  • Medical computer monitors
  • Sleep apnea devicesMEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-FIG-1 (2)

GTIN CODE

Description

  • RPS-60 is a 60W highly reliable green PCB-type medical power supply with a high power density on the 4″ by 2″ footprint.
  • It accepts 90~264VAC input and offers various output voltages between 3.3V and 48V.
  • The working efficiency is up to 86% and the extremely low no-load power consumption is down below 0.75W.
  • RPS-60 can be used for Class I (with FG) system design.
  • The extremely low leakage is current EMS BEEN SO 22 SEEN 501, pero in citing all kinds medical red ulation contact medical system equipment.

Model Encoding

MEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-FIG-1 (3)

SPECIFICATION

MODEL RPS-60-3.3 RPS-60-5 RPS-60-12 RPS-60-15 RPS-60-24 RPS-60-48
OUTPUT DC VOLTAGE 3.3V 5V 12V 15V 24V 48V
RATED CURRENT 10A 10A 5A 4A 2.5A 1.25A
CURRENT RANGE 0 ~ 11A 0 ~ 11A 0 ~ 5.5A 0 ~ 4.4A 0 ~ 2.75A 0 ~ 1.375A
RATED POWER 33W 50W 60W 60W 60W 60W
PEAK LOAD(10sec.)        Note.2 36.3W 55W 66W 66W 66W 66W
RIPPLE & NOISE (max.) Note.3 60mVp-p 60mVp-p 60mVp-p 100mVp-p 100mVp-p 100mVp-p
VOLTAGE ADJ. RANGE 3.1 ~ 3.6V 4.75 ~ 5.5V 11.4 ~ 13.2V 13.5 ~ 16.5V 22.8 ~ 27.6V 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.4 ±2.0% ±2.0% ±2.0% ±2.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 500ms, 30ms/230VAC            500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC            12ms/115VAC at full load
INPUT VOLTAGE RANGE 90 ~ 264VAC          127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 74% 79% 84% 85% 87% 86%
AC CURRENT (Typ.) 1.8A/115VAC             1 A/230VAC
INRUSH CURRENT (Typ.) COLD START 60A/230VAC           30A/115VAC
LEAKAGE CURRENT(max.) Note.5 Earth leakage current < 130μA/264VAC , Touch current < 100μA/264VAC
PROTECTION  

OVERLOAD

115 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
 

OVER VOLTAGE

3.8 ~ 5V 5.7 ~ 6.8V 13.8 ~ 16.2V 17.2 ~ 20.3V 28.4 ~ 32.4V 55.2 ~ 64.8V
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.6 3000 meters
SAFETY & EMC

(Note 8)

 

SAFETY STANDARDS

IEC62368-1, UL62368-1, TUV BS EN/EN62368-1, IEC60601-1, TUV BS EN/EN60601-1, UL ANSI / AAMI ES60601-1

(3.1 version), CAN/CSA-C22.2 No. 60601-1:14 – Edition 3, EAC TP TC 004 approved; Design refer to BS EN/EN60335-1

ISOLATION LEVEL Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
WITHSTAND VOLTAGE I/P-O/P:4KVAC  I/P-FG:2KVAC  O/P-FG:1.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25℃/ 70% RH
EMC EMISSION Parameter Standard Test Level / Note
Conducted emission BS EN/EN55011 (CISPR11) Class B
Radiated emission BS EN/EN55011 (CISPR11) Class B
Harmonic current BS EN/EN61000-3-2 Class A
Voltage flicker BS EN/EN61000-3-3 —–
EMC IMMUNITY BS EN/EN55035 ,BS EN/EN60601-1-2
Parameter Standard Test Level / Note
END BS EN/EN61000-4-2 Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility BS EN/EN61000-4-3 Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT bursts BS EN/EN61000-4-4 Level 3, 2KV
Surge susceptibility BS EN/EN61000-4-5 Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted susceptibility BS EN/EN61000-4-6 Level 3, 10V
Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m
 

Voltage dip, interruption

BS EN/EN61000-4-11 100% dip 1 period, 30% dip 25 periods, 100% interruptions 250 periods
OTHERS MTBF 5153.0K hrs min.       Telcordia SR-332 (Bellcore); 353.6K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION (L*W*H) 101.6*50.8*29mm or 4″ * 2″ *1.141″ inch
PACKING 0.15Kg; 96pcs/15.4Kg/0.89CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 2 ℃ of ambient temperature.

2.  33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.

3.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.

4.  Tolerance: includes set up tolerance, line regulation, and load regulation.

. Touch current was measured from primary input to DC output.

6. The ambient temperature derating of 3. ℃/1000m with fanless models and of ℃/1000m with fan models for operating altitude higher than 2000m(6 00ft).

7.  Heat Sink HS1,HS2 can not be shorted.

8.  The power supply is considered a component that will be installed into the final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Diagram

Block Diagram

MEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-FIG-1 (4)

Output Derating

MEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-FIG-1 (5)

Output Derating VS Input Voltage

MEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-FIG-1 (6)

Mechanical Specification 

MEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-FIG-1 (7)

AC Input Connector (CN1): JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/N  

JST VHR or equivalent

JST SVH-21T-P1.1 or equivalent
2 No Pin
3 AC/L

DC Output Connector (CN2): JST B4P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2 +V JST VHR

or equivalent

JST SVH-21T-P1.1

or equivalent

3,4 -V

MEAN-WELL-RPS-60-Series-Reliable-Green-Medical-Power-Supply-FIG-1 (8): Grounding Required

  1. HS1, HS2 cannot be shorted.
  2. M1 is safety ground. For better EMC performance, Please secure an electrical connection between M1, M2, and chassis grounding.

Installation Manual