CORSTON 14623 Ealing Ground Spotlight Owner’s Manual

Home » CORSTON » CORSTON 14623 Ealing Ground Spotlight Owner’s Manual

14623 Ealing Ground Spotlight
Owner’s ManualCORSTON 14623 Ealing Ground SpotlightEagling Ground Spotlight Instructions

14623 Ealing Ground Spotlight

These products must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.

Location Exterior
Class Class 1
IP Rating IP56
Driver Required No
Fire Rating No
Cable Length 3000mm
Light Source GU10
Max Wattage Bulb Dependant
Lamp Included 6W
Switched No
Dimmable No
Rated Voltage 220-240V
Rated Frequency 50 /60Hz

Included:

CORSTON 14623 Ealing Ground Spotlight - feager

1. Align spotlight direction with spike 2. Remove light and hammer spike into position
CORSTON 14623 Ealing Ground Spotlight - spike CORSTON 14623 Ealing Ground Spotlight - hammer
3. Cover base with brass cover 4. Feed cable into position
CORSTON 14623 Ealing Ground Spotlight - spike1 CORSTON 14623 Ealing Ground Spotlight - Feed cable
5. Place light and tighten collar 6. Install bulb
CORSTON 14623 Ealing Ground Spotlight - tighten collar CORSTON 14623 Ealing Ground Spotlight - bulb

7. Install glass cover using suction tool

CORSTON 14623 Ealing Ground Spotlight - glass cover

Eagling Path Spotlight Instructions

These products must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.

Location Exterior
Class Class 1
IP Rating IP56
Driver Required No
Fire Rating No
Cable Length 3000mm
Light Source GU10
Max Wattage Bulb Dependant
Lamp Included 6W
Switched No
Dimmable No
Rated Voltage 220-240V
Rated Frequency 50 /60Hz

Included:

CORSTON 14623 Ealing Ground Spotlight - tighten collar1

  1. Align spotlight direction with spikeCORSTON 14623 Ealing Ground Spotlight - spike 1
  2. Remove light and hammer spike into positionCORSTON 14623 Ealing Ground Spotlight - hammer1
  3. Cover base with brass coverCORSTON 14623 Ealing Ground Spotlight - spike2
  4. Feed cable into positionCORSTON 14623 Ealing Ground Spotlight - tighten collar2
  5. Place light and tighten collarCORSTON 14623 Ealing Ground Spotlight - tighten collar3
  6. Install bulbCORSTON 14623 Ealing Ground Spotlight - bulb1
  7. Install glass cover using suction toolCORSTON 14623 Ealing Ground Spotlight - bulb2

Ealing Ground Spotlight Instructions
These products must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.

Location Exterior
Class Class 1
IP Rating IP56
Driver Required No
Fire Rating No
Cable Length 3000mm
Light Source GU10
Max Wattage Bulb Dependant
Lamp Included 6W
Switched No
Dimmable No
Rated Voltage 220-240V
Rated Frequency 50 /60Hz

Included:
CORSTON 14623 Ealing Ground Spotlight - tighten collar 4

  1. Drill holes, set anchors and screw base to wallCORSTON 14623 Ealing Ground Spotlight - screw base
  2. Feed cable and sit base with brassCORSTON 14623 Ealing Ground Spotlight - screw base 1
  3. Place light and tighten collarCORSTON 14623 Ealing Ground Spotlight - tighten collar4
  4. Install bulbCORSTON 14623 Ealing Ground Spotlight - tighten collar5
  5. Install glass cover using suction toolCORSTON 14623 Ealing Ground Spotlight - tighten collar6

Ealing Ground Spotlight Instructions
These products must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.

Location Exterior
Class Class 1
IP Rating IP56
Driver Required No
Fire Rating No
Cable Length 3000mm
Light Source GU10
Max Wattage Bulb Dependant
Lamp Included 6W
Switched No
Dimmable No
Rated Voltage 220-240V
Rated Frequency 50 /60Hz

Included:
CORSTON 14623 Ealing Ground Spotlight - Included

  1. Drill holes, set anchors and screw base to wallCORSTON 14623 Ealing Ground Spotlight - wall
  2. Feed cable through grommetCORSTON 14623 Ealing Ground Spotlight - Feed cable2
  3. Make connections using WagesCORSTON 14623 Ealing Ground Spotlight - tighten collar7
  4. Attach base with grub screwsCORSTON 14623 Ealing Ground Spotlight - grub screws
  5. Install bulbCORSTON 14623 Ealing Ground Spotlight - Install bulb
  6. Install glass cover using suction toolCORSTON 14623 Ealing Ground Spotlight - tighten collar 8

Waterproof Connector Instructions

These products must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.

Location Exterior
IP Rating IP56
Fire Rating No

Included:
CORSTON 14623 Ealing Ground Spotlight - Included 2

  1. Connect wires using waterproof terminalCORSTON 14623 Ealing Ground Spotlight - terminal
  2. Screw on clamps
  3. Hide connection
  4. Swap grommets when using armored cable

Waterproof Connector Instructions
These products must be installed in dry conditions by a qualified electrician. Turn off electrical supply to circuit before installation.

Location Exterior
IP Rating IP56
Fire Rating No

Included:

  1. Connect wires using waterproof terminal
  2. Screw on clamps
  3. Hide connection
  4. Swap grommets when using armored cable