STEAM CLEANER
USER MANUAL
Please read the user manual thoroughly before operating the machine. If you encounter any problems during use, please contact us first.
Contents
After-sales Service
If you encounter any problems during use, please first refer to the problems and solutions section of the manual. If the manual still does not solve your problem, please do not worry, you can contact us first. We provide 24-hour online support services.
Please don’t worry, we will provide you with a solution that will satisfy you.
How to contact the seller on Amazon
Go to Your Orders.
Find your order in the list.
Select Problem with order.
Choose your topic from list displayed.
Select Contact seller
Product description:
This equipment is a multi-functional cleaning equipment for cleaning air conditioners, range hoods, refrigerators, washing machines and other household appliances. The equipment adopts the working principle of instant high temperature and high pressure, which realizes the disassembly and cleaning of the range hood and air conditioner surface.
Product parameters:
Voltage | 220V 50Hz | Power | 3000W |
Product model | STQX-02A | Steam temperature | ≥100°C (212°F) |
Steam pressure | ≥3 KGF/CM2 | Power cord length: | 1.8 m |
Power cord length | 1.8m | Steam pipe length | 2.5m |
Size | 430*312*292mm | Weight | 3.7 kg |
Accessories installation:
Install the nozzle
- Done
- Use with plastic brush
- Use with copper brush
- Use with large plastic brush
- Install the stainless steel elbow
- Done
- Use with plastic brush
- Use with copper brush
- Use with big plastic brush
- Put the inlet hose into the bucket
- Connect the power supply
- Turn on the steam cleaner
- Adjusting wet and dry steam
- Press the handle of the spray gun, wait for 15s, and spray steam
- Start working
Precautions:
- Liquids or vapors should not be directed towards people or animals, and should not be directed towards devices containing electrical components, such as the interior of an oven.
- The power plug needs to be unplugged after use and maintenance of the steam cleaner
Packing list:
1) Steam cleaner host *1 2) 1m inlet pipe *1 3) Flashlight (without battery)*1 |
4) Spray gun*1 5) Water tank*1 6) Stainless steel elbow *1 |
7) Large plastic brush*1 8) Plastic brush*2 9) Copper brush*2 |
Common problem:
Problem | Cause of issue | Solution |
The machine over heats or emits smoke | ① The equipment does not absorb water ② The equipment does not absorb enough water ③ The insulation cotton of the roasting equipment causes |
①②Solution:Stop the machine for 20 minutes and wait for the machine to cool before using it to ensure that the equipment absorbs water and the dry humidity is adjusted to the maximum. ③Note:This phenomenon will only appear when it is just used, and after three or four times of use, the phenomenon of smoking will not appear again. |
Main uni switch ligh does not ligh up afte plugging in | ① The socket is loose or faulty ② The problem of the machine switch |
① Solution: Check whether the socket is powered on and whether it carries more than 2500W of power. ② Solution: the switch needs to be replaced |
Lengt hened elbow leaks | The rubber ring is damaged | Solution: Put another rubber ring or replace it with a new rubber ring and tighten it. |
Too much water in the steam | Excessive water content is a normal phenomenon | Solution: If dry steam is required, you can adjust the wet and dry adjustment knob to the maximum. |
Low steam temperature | The temperature out of the nozzle is the highest, which can reach more than 100 ℃. With the increase of the spray distance, the temperature will gradually decrease. |
Note: Since the spray is steam, the temperature will drop rapidly in a short time. If you need to achieve the best cleaning effect, please keep the distance between the nozzle and the stain within 3cm. |
Does not produce steam | No steam due to scale blockage | Solution: It is necessary to remove the scale inside the machine, and use a descaling agent or citric acid to inhale the same as when the steam engine is working, and it takes three to five minutes. |
Automatic shutdown or small steam output | Shutdown or small steam output due to scale blockage | Solution: Twist the steam outlet pipe to see if the main engine can emit steam, and clean the scale on the inner wall of the main steam outlet |
The water pump does not work The performance is as follows: the switch indicator light is normal, but the sound of pumping water cannot be heard, and there is no water flow in the water inlet pipe. |
① The terminal wire connected to the water pump falls off ② The scale is not cleaned regularly, causing the evaporator to be blocked. Solution: Try to remove the scale first, if the machine still can’t work, you need to replace the evaporator. ③The water pump is broken |
① Solution: disassemble the machine and re-fix the terminal wire ② Solution: Try to remove the scale first, if the machine still can’t work, you need to replace the evaporator. ③ Solution: replace the water pump. |
Machine maintenance:
- After accumulative use for 10 hours, add water with citric acid or descaling agent, let the machine inhale the water and work for a few minutes to remove the internal scale. (If the water quality is poor, the scale needs to be cleaned regularly)
- This equipment cannot inhale water containing detergents to prevent corrosion or blockage of the machine, and shorten the use time.
- The device should be placed at room temperature to avoid freezing of the residual moisture inside the machine and blockage caused by placing it in a place where the temperature is too low.
Warranty:
We provide a one-year warranty, if there are any problems during use, please contact us in time, we will do our best to provide you with after-sales service.