POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight Installation Guide

Home » POWER-LITE » POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight Installation Guide

POWER-LITE logoINSTALLATION MANUAL

POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated DownlightLED FIRE RATED
DOWNLIGHT
DL12W-FR-CC-IP65

DL12W-FR-CC-IP65 LED Fire Rated Downlight

Warning

  1. Before installation or maintenance ensure that the mains supply to the luminaire is switched off and the circuit supply fuses are removed or circuit breaker turned off.
  2. A qualified electrician MUST be consulted or used for the installation of this luminaire.
  3. The luminaire must be installed to there elegant building regulations.
  4. Check that the total load on the circuit, including when this luminaire is fitted, does not exceed the rating of the circuit cable fuse or circuit breaker.

POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - icon

POWER-LITE LED-DL35W LED Cob Downlight - icon3 Technical Specifications

Input Voltage: 200-240VAC 50/60Hz
Power: 12W
Beam Angle: 60 degree
IP Rating: IP65/IP44
PF: >0.9
Cut Out: 90mm
Tri Cooler 3000K, 4000K, 6000K
Lumens: 900, 1000, 950

POWER-LITE LED-DL35W LED Cob Downlight - icon3 Dimensions

POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - Dimensions

POWER-LITE LED-DL35W LED Cob Downlight - icon3 Installation Instructions

  1. Switch off power
  2. Prepare cut-out hole in your surface to specified dimensions as stated in above drawing.POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - drawing
  3. Select desired cooler output via front mounted switch -WW -3000K, CW-4000K, DL-6000KPOWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - drawing2
  4. Connect the mains power cable to the driverPOWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - cable
  5. Place driver into recess then push back spring clips and insert luminaire into recess.POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - cable1
  6. Place one of the supplied magnetic bezels to complete installation.POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - drawing1
  7. Switch power on at circuit
    Note:
    For high voltage circuit insulation testing disconnect mains input supply firstPOWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - icon2(Do not circuit test using a megger)
    Changing Colour Temperature
    To change colour temperature after installation
    POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - cable2a. Ensure the power is switched off.
    b. Remove magnetic bezel and switch to desired color temperature
    c. Replace bezel
    d. Switch power on at circuit

Installation Spacing

POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - cable3

RISK OF FIRE -Required clearance from structural members and building elements

POWER-LITE DL12W-FR-CC-IP65 LED Fire Rated Downlight - cable4HCB=20mm
SCB=20mmPOWER-LITE logoPOWER-LITE LED-DL35W LED Cob Downlight - icon 1800 909 306
POWER-LITE LED-DL35W LED Cob Downlight - icon1nedlandsgroup.com.au
POWER-LITE LED-DL35W LED Cob Downlight - icon2[email protected]

Leave a Comment