Safety instructions

Thank you for choosing our FOS IQ Par lp65. for your own safety, please read this user manual carefully

BEFORE YOU INITIAL START· UP!

CAUTION!
Be careful with your operations. With a high voltage, you can suffer a dangerous electric shock when touching the wires!

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.

CAUTION!

  • Keep this device away from rain and moisture!
  • Unplug the mains lead before opening the housing!

Important:

  • The manufacturer will no_ accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
  • Please consider that damages caused by manual modifications to the device are not subject to warranty.
  • During the operation the housing becomes hot). Allow the fixture to cool for approximately 20 minutes prior to manipulating it.
  • Make sure that the available voltage is not higher than stated on the rear panel.

WARNING!
This unit does not contain an ON/OFF switch. Always disconnect the power input cable to completely remove power from the unit when not in use or before cleaning or servicing the fixture.

  • Make sure that the power cord is never crimped or damaged by sharp edges. Check the device and the power cord from time to time.
  • Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
  • This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to the earth.
  • The electric connection, repairs, and servicing must be carried out by a qualified employee.
  • Do not connect this device to a dimmer pack.
  • Do not switch the fixture on and off in short intervals as this would reduce the lamp’s life.
  • During the initial start-up, some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
  • Do not touch the device’s housing with bare hands during its operation (the housing becomes hot)!
  • For replacement use lamps and fuses of the same type and rating only.

CAUTION! EYE DAMAGES!
Avoid looking directly into the light source (meant especially for epileptics)!

UNPACKING

Please carefully unpack it when you receive the fixture and check whether it is damaged during the transportation. And please check whether the following items are included inside the box:

The FOS IQ Par lp65 is made of a new type of high-temperature strength of engineering plastics and cast aluminum casing with a nice outlook. The fixture is designed and manufactured strictly following CE standards, complying with the international standard DMX512 protocol. It’s available independently controlled and linkable with each other for operation. And it is applicable for large-scale live performances, theater, studios, nightclubs, and discos. This manual covers important information on installation and applications. Meanwhile, please keep this manual well for future needs.

TECHNICAL INFORMATION

Features
  • 19*12W 6-in-1 LEDs (RGBWAUV)
  • 50, 000 hours lifespan and low power consumption
  • High light output with even color mixing
  • 26-degree beam angle
  • 0-100% Smooth LED dimmer
  • Flicker-free control system for TV production and film
  • High-efficiency LED shutter with variable speed
  • Strobe effect with 1-25T /s and pulse effect
  • Built-in default programs
  • Macro effects
  • 30/12 DMX channels USITT MDX-512
  • 4-Button LED display control menu DMX512, master-slave and sound activated controllable or auto
  • Noise-free efficient aluminum cooling system
  • I P65 protection rating
  • IP-rated power connector IN/OUT
  • IP-rated 3-pin DMX connectors IN/OUT
  • -35 ·c~45 ·cambient temperature
  • Dual mounting brackets for installation/floor stand
  • WDMX operations
  • 3 pixels rings
Specifications
  • Input Voltage: AC90-260V 50/60Hz
  • LEDQuantities: 19PCS 6IN1-12WLED
  • Control Signal: DMX512,master-slave and sound activated or auto operation
  • Control Channel: 22/10 DMX Channels USITT DMX-512
  • Power Consumption: 266W
  • Dimensions: 155(D)*299(W)*2 79(H)mm
  • Packing Dimensions: 370(D)*335(W)*245(H)mm
  • Net Weight: 4.65kg
  • Gross Weight: 5.65kg

PHOTOMETRIC DATA

Photometric Beam Angle Data 

FOS-technologies-IQ-Par-IP65-HEX-Party-Light-fig- (5)

OPERATION INSTRUCTIONS

  • The FOS IQ Par lp65 is for beam effect for on-site decoration purposes.
  • Don’t turn on the fixture if it’s been through severe temperature differences like after transportation because it might damage the light due to the environmental changes. So make sure to operate the fixture until it is in normal temperature.
  • This light should be kept away from strong shaking during any transportation or movement.
  • Don’t pull up the light by only the head, or it might cause damage to the mechanical parts.
  • Don’t expose the fixture in overheat, moisture, or an environment with too much dust when installing it. And don’t lay any power cables on the floor. Or it might cause electronic shock to the people.
  • Make sure the installation place is in good safe condition before installing the fixture.
  • Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture.
  • Make sure the lens are in good condition. It’s recommended to replace the units if there are any damages or severe scratches. Make sure the fixture is operated by qualified personnel who know the fixture before using it.
  • Keep the original packages if any second shipment is needed. Don’t try to change the fixtures without any instruction from the manufacturer or the appointed

INSTALLATIONS

Cautions:

  • For added protection mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might be reached by unauthorized personnel.
  • Before mounting the fixture to any surface, make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
  • Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
  • Never stand directly below the device when mounting, removing, or servicing the fixture. from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).FOS-technologies-IQ-Par-IP65-HEX-Party-Light-fig- (6)

Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails.

Mounting points:
Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet.

FOS-technologies-IQ-Par-IP65-HEX-Party-Light-fig- (7)

Clamp Mounting:
FOS IQ Par lp65 provides a unique mounting bracket assembly that integrates the bottom of the base, and the safety cable rigging point in one unit (see the illustration below). When mounting this fixture to the truss be sure to secure an appropriately rated clamp to the included omega bracket using a M 1 O screw fitted through the center hole of the “Hanging Kit”. As an added safety measure be sure to attach at least one properly rated safety cable to the fixture using one of the safety cable rigging point integrated in the base assembly.

CONTROL CONNECTION

FOS-technologies-IQ-Par-IP65-HEX-Party-Light-fig- (8)

  • Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the moving head. You can chain multiple Moving head together through serial linking. The cable needed should be two core, screened cable with XLR input and output connectors. Please refer to the diagram below. DMX-512 connection with DMX terminator.
  • For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a3 resistor connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the chain. Please see illustrations below.FOS-technologies-IQ-Par-IP65-HEX-Party-Light-fig- (9)

MENU OPERATIONS

FOS-technologies-IQ-Par-IP65-HEX-Party-Light-fig- (10)

DMX PROTOCOL

Mode/Channel Value Function
CH30 CH12
1 1 Dimmer
0..255 Dimmer 0%…100%
 

 

 

 

2

 

 

 

 

2

Shutter
0..31 Shutter closed
32..63 shutter open
64..95 Strobe effect slow to fast
96..127 shutter open
128..159 Pulse-effect in sequences slow to fast
160..191 shutter open
192..223 Random strobe effect slow to fast
224..255 shutter open
3 3 Red
0..255 0-100% Red dimmer from dark to bright
4 4 Green
0..255 0-100% Green dimmer from dark to bright
5 5 Blue
0..255 0-100% Blue dimmer from dark to bright
6 6 White
0..255 0-100% White dimmer from dark to bright
7 7 Amber
0..255 0-100% Amber dimmer from dark to bright
8 8 UV
0..255 0-100% UV dimmer from dark to bright
9 Red1
0..255 0-100% Red1 dimmer from dark to bright
10 Green1
0..255 0-100% Green1 dimmer from dark to bright
11 Blue1
0..255 0-100% Blue1 dimmer from dark to bright
12 White1
0..255 0-100% White1 dimmer from dark to bright
13 Amber1
0..255 0-100% Amber1 dimmer from dark to bright
14 UV1
0..255 0-100% UV1 dimmer from dark to bright
15 Red2
0..255 0-100% Red2 dimmer from dark to bright
16 Green2
0..255 0-100% Green2 dimmer from dark to bright
17 Blue2
0..255 0-100% Blue2 dimmer from dark to bright
18 White2
0..255 0-100% White2 dimmer from dark to bright
19 Amber2
0..255 0-100% Amber2 dimmer from dark to bright
20 UV2
0..255 0-100% UV2 dimmer from dark to bright
21 Red3
0..255 0-100% Red3 dimmer from dark to bright
22 Green3
0..255 0-100% Green3 dimmer from dark to bright
23 Blue3
0..255 0-100% Blue3 dimmer from dark to bright
24 White3
0..255 0-100% White3 dimmer from dark to bright
25 Amber3
0..255 0-100% Amber3 dimmer from dark to bright
26 UV3
0..255 0-100% UV3 dimmer from dark to bright
 

 

 

 

 

 

27

 

 

 

 

 

 

9

Macro Color
0..15 No Function
16..31 Red
32..47 Green
48..63 Blue
64..79 White
80..95 Red+Green
96..111 Red+Blue
112..127 Red+White
128..143 Green+Blue
144..159 Green+Whi te
160..175 Blue+Wtihe
176..191 R+G+B
 

 

 

 

 

27

 

 

 

 

 

9

192..207 R+G+B+W
208..212 2700K
213..217 3200K
218..222 3500K
223..227 5000K
228..232 5500K
233..237 6000K
238..242 6500K
243..247 7000K
248..255 8000K
 

 

 

 

 

28

 

 

 

 

 

10

Color Temp
0..15 No Function
16..45 Below3200K
46..75 3200K – 3500K
76..105 3500K – 5000K
106..135 5000K – 5500K
136..165 5500K – 6000K
166..195 6000K – 6500K
196..225 6500K – 7000K
226..255 7000K – 8000K
 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

11

Macro RUN
0..15 No function
16..31 Macro Run 1
32..47 Macro Run 2
48 ..63 Macro Run 3
64..79 Macro Run 4
80..95 Macro Run 5
96..111 Macro Run 6
112..127 Macro Run 7
128..143 Macro Run 8
144..159 Macro Sound 1
160..175 Macro Sound 2
176..191 Macro Sound 3
192..207 Macro Sound 4
208..223 Macro Sound 5
224..239 Macro Sound 6
240..255 Macro Sound 7
30 12 Macro Speed
0..255 Macro Speed from Slow To Fast

Maintenance and cleaning

It is absolutely essential that the fixture is kept clean and that dust, dirt, and smoke-fluid residues must not build upon or within the fixture. Otherwise, the fixture’s light output will be significantly reduced. Regular cleaning will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life. A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should alcohol or solvents be used!

DANGER!
Disconnect from the mains before starting any maintenance work

The front objective lens will require weekly cleaning as smoke-fluid tends to build up residues, reducing the light output very quickly. The cooling fans should be cleaned monthly.
The interior of the fixture should be cleaned at least annually using a vacuum cleaner or an air jet. Dichroic colour filters. Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum cleaner.
Important! Check the air filters periodically and clean them before they become clogged!
Clean two air filters placed in the fixture’s covers and two in the fixture base. Use a vacuum cleaner or compressed air or you can wash them and put them back dry.
After replacing the air filters, reset the elapsed time counter in the menu “Information” (information —>Air Filters—>Elapsed Time).

Replacing the fuse. Before replacing the fuse, unplug the main lead.

  1. Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing (anti-clockwise).
  2. Remove the old fuse from the fuse holder.
  3. Install the new fuse in the fuse holder (only the same type and rating).
  4. Replace the fuse holder in the housing and fix it.

Wireless function

  1. Choose the wireless DMX on the light display “SET”—>”Signal setting”—>”Wireless DMX”(ULd showed on display)
  2. Wireless transmitter transmits a signal, press the “UP” and “ENTER” buttons at the same time on the light display until you see the indicator flashing yellow
  3. The pairing signal in the transmitter would see an indicator flashing green on the light display

In the Use mode, Description of Status Indicator:

Protocol Action Status Description
W-DMXReceive

Protocol

 

White

 

Connection is not Established

Red Deleting Connection
Red(Fast-Flash) Connection is Lost
Green(Fast-Flash) Connecting to Transmitter
Green{Slow-Flash) Connected, Without OMX Signal
Green Connected, Receiving OMX Signal