CONTENTS

Cell2-UR06-LED-Flush-Mount-Kit-1

WIRING & FUNCTIONS

Cell2-UR06-LED-Flush-Mount-Kit-2

NOTE: Each warning mode may be set to different Flash Pattern & Colour Mode.

OPERATION

For Synchronization:
Connect wires of all lightheads together for synchronization. (All the lightheads should be set to the same Flash Pattern)

For Warning Colour Mode:
Each Warning Mode Cell2-UR06-LED-Flush-Mount-Kit-12may be set to warning or Cell2-UR06-LED-Flush-Mount-Kit-13  in , Cell2-UR06-LED-Flush-Mount-Kit-14 Cell2-UR06-LED-Flush-Mount-Kit-15 . To change Warning Colour Mode:

  1. Choose the desired warning mode to change and apply +VDC to its activation wire Cell2-UR06-LED-Flush-Mount-Kit-12 with wire simultaneously to enter Setting Mode; lighthead will display short flashes in its current Colour Mode.
    • Colour 1 (Warning Mode 1 Pre-set)
    • Colour 2 (Warning Mode 2 Pre-set)
    • Colour 1 alt. 2 (Warning Mode 3 Pre-set)
  2. Remove wire from +VDC and momentarily apply to +VDC again to change Colour Mode.
  3. Once in desired Colour Mode, save and Exit Setting Mode by powering off the lighthead.

For Flash Pattern:
While a warning mode is actiaved, momentarily apply +VDC to wire:

    • once for next pattern
    • quick three times to reset to FP#1 (see flash pattern chart)
Flash Pattern
1 Double [2Hz] 15 Random
2 Single [2Hz] 16 Double [2Hz] (SPLIT)
3 Triple  [2Hz] 17 Single [2Hz] (SPLIT)
4 Quad  [2Hz] 18 Triple  [2Hz] (SPLIT)
5 Single 19 Quad  [2Hz] (SPLIT)
6 Double 20 Single           (SPLIT)
7 Quad 21 Double         (SPLIT)
8 Quint 22 Quad            (SPLIT)
9 Mega 23 Quint            (SPLIT)
10 Ultra 24 Mega            (SPLIT)
11 Single-Quad 25 Ultra             (SPLIT)
12 Single H/L 26 Single-Quad (SPLIT)
13 Steady EF * 27 Single H/L    (SPLIT)
14 Steady Scene

INSTALLATION – FLUSH MOUNT

  1. Select a mounting location and drill one 1″ (25.4mm) cut-out.
    NOTE: Mounting surface thickness @ 0.8~2.0mm
    Cell2-UR06-LED-Flush-Mount-Kit-3
  2. From the front, install MOUNTING GROMMET onto the cut-out, and then insert the LIGHTHEAD.
    Cell2-UR06-LED-Flush-Mount-Kit-4
  3. Where necessary, apply silicone around the reverse side to prevent from rotating.
    Cell2-UR06-LED-Flush-Mount-Kit-5
  4. Where necessary, apply silicone around the reverse side to prevent from rotating.
    Cell2-UR06-LED-Flush-Mount-Kit-6

INSTALLATION – BRACKET MOUNT (sold-separately)

  1. From the front, install the MOUNTING GROMMET onto the BRACKET, and insert the LIGHTHEAD.
    Cell2-UR06-LED-Flush-Mount-Kit-8
  2. Ensure that triangle mark on the lens is aligned vertically.
    Cell2-UR06-LED-Flush-Mount-Kit-7
  3. Secure the LIGHTHEAD onto the BRACKET with a screw.
    Cell2-UR06-LED-Flush-Mount-Kit-8
  4. Secure the BRACKET onto the desired mounting surface with screws.

WIRING 2 KITS TOGETHER

Cell2-UR06-LED-Flush-Mount-Kit-11

Below is a schematic diagram for wiring 2 kits together.
Yellow wires from both controllers must be connected together for synchronization.

  • When Flash Pattern 1~12 is selected: All Heads will flash simultaneously.
  • When Flash Pattern 15~26 is selected: Head 1A&2A will flash alternatively with Head 1B&2B.
    * refer to Flash Pattern chart on opposite page.

NOTE: To have Head 1A&2B alternate with 1B&2A, simply reverse the lightheaded outlets on one of the Controllers; (both kits must be in Flash Pattern 15~26).

NOTE: The mounting area for controllers varies from vehicle to vehicle.