cell2 ES3 3-LED Narrow Profile Lighthead Instruction Manual

Home » Cell2 » cell2 ES3 3-LED Narrow Profile Lighthead Instruction Manual

cell2

cell2 ES3 3-LED Narrow Profile Lighthead

cell2 ES3 3-LED Narrow Profile Lighthead Product

Surface Mount

cell2 ES3 3-LED Narrow Profile Lighthead (1)

 

Connect YELLOW wires of all heads together for synchronization (All heads should be set to the same pattern)

For Simultaneous or Alternating Flash:

  1. Apply +VDC to RED and YELLOW wires simultaneously to enter
    Grouping mode; lighthead will display short (single or double) flashes:

    • Single flash = Group1
  2. Remove the YELLOW wire from +VDC and momentarily apply to +VDC to change Groups:
    Heads in the same Group flash together.

    1. Group1 Heads alternate with Group2 Heads
    2. Double flash = Group2 Heads

For Flash Patterns: Momentarily apply +VDC to

YELLOW wire: once for next pattern quick three times to reset to FP#1

NOTE: This unit may not be factory-set at FP#1.

  Double [2Hz] 9 Double [SAE]
2 Single [2Hz] 10 Triple [SAE]
3 Triple [2Hz] 11 Quad [SAE]
4 Quad [2Hz] 12 Quint [SAE]
5 Random 13 Ultra [SAE]
6 Steady 14 Single-Quad
7 Single [SAE, CA13] 15 Single H/L
8 Mega 16 Single-Triple-Quint

Universal Bracket (Angle-Adjustable)

cell2 ES3 3-LED Narrow Profile Lighthead (2)

L-Bracket (Front)

cell2 ES3 3-LED Narrow Profile Lighthead (3)

L-Bracket (Rear)

cell2 ES3 3-LED Narrow Profile Lighthead (4)