magic-pak 5MHP4-12-241FP Electric Heat Packaged Unit Instruction Manual

Home » magic-pak » magic-pak 5MHP4-12-241FP Electric Heat Packaged Unit Instruction Manual

magic-pak-LOGO

magic-pak 5MHP4-12-241FP Electric Heat Packaged Unit

magic-pak-5MHP4-12-241FP-Electric-Heat-Packaged-Unit-PRODUCT

MODEL NUMBER GUIDE

magic-pak-5MHP4-12-241FP-Electric-Heat-Packaged-Unit-FIG-1

APPLICATIONS

  • MagicPak units are designed for use in all multifamily applications, such as: apartments, condominiums, student housing and senior living
  • Installation in conditioned and non-conditioned mechanical spaces

UNIT APPROVALS

ETL (INTERTEK)

  • Design certified by ETL (Intertek) to latest edition of UL 1995
  • Certified for the U.S. and Canada
  • Certified for less than 1.4% cabinet air leakage using ASHRAE Standard 193
  • Factory-installed electric heaters are ETL listed for the U.S. and Canada
  • Rated with a 5kA Short Circuit Current Rating (SCCR) in accordance with RMS Symmetrical per UL 508A
  • Refer to Unit Electrical and Physical Data table for additional details

AHRI/DOE

  • Certified to AHRI Standard 210/240-2008; refer to the AHRI Directory for AHRI certificates
  • Rated and tested in accordance with DOE test procedures and Federal Trade Commission (FTC) labeling regulations

CORROSION PROTECTION

  • Epoxy coating is specifically designed for use on HVAC type coils and demonstrates 6800+ hours of Sea Water Acetic Acid Testing (SWAAT) per ASTM G85:A3

SOUND RATING

  • Outdoor sound level measurements tested per ANSI/AHRI Standard 270
  • Refer to Outdoor Sound Rating & Cabinet Air Leakage table for additional details

ALUMINUM LOUVER – PAINT SPECS

  • Standard and impact-resistant louvers meet AAMA 2605 specifications

WARRANTY COMPRESSOR

  • Five (5) years limited parts warranty

ALL OTHER COVERED COMPONENTS

  • Refer to Equipment Limited Warranty for additional details

STANDARD FEATURES

AIRFLOW CHOICE 

  • Factory shipped ready for top supply and return duct connections
  • Return air may be brought in through the optional front return opening
    • NOTE: If ductwork is attached to the optional front return opening, provisions to service unit filter must be provided
    • NOTE: Filter may need to be relocated to a suitable location outside the cabinet for ease of service
  • Ducted or free/non ducted return configuration, which may utilize the top or front as return points
  • Front access panel doubles as cover for top return (except 3.0 ton)

ELECTRICAL CONNECTIONS & GAUGE PORTS

  • Line voltage knockouts (two concentric) to accommodate field required wire size
  • Thermostat connections are located at the top of the cabinet
  • Two gauge ports are located within the lower compartment of the unit
  • Refer to Unit Dimension figure for additional details

CABINET

  • Embossed galvanized steel cabinet
  • Indoor section of the cabinet insulated with 0.5 in. dual density fiberglass insulation
  • Outdoor section of the cabinet insulated with 0.5 in. weather-resistant polystyrene insulation

INTERNAL FILTER

  • Tool-less filter access
  • Factory-installed 1 in. filter rack with washable filter
  • Field-supplied filters up to MERV 6 can typically be installed in the filter slot internal to unit in lieu of washable filter, when proper duct design is applied
  • If a higher resistance filter is field installed in the unit, the added resistance must be included in the external static pressure and must not exceed 0.5 in. w.c. including ductwork
  • Refer to Factory Filter Size and Pressure Drop and Blower Performance tables for additional details

VENTILATION AIR

  • Units are outfitted with ventilation air openings and are shipped with the openings sealed
  • Refer to Ventilation Air Capability table and Optional Field-Installed Accessories section for additional details
  • Check that equipment complies with all applicable building codes, laws, and regulations for its intended use prior to installation

REFRIGERATION SYSTEM

  • Factory charged with R-410A refrigerant
  • Factory sealed and tested
  • Refer to Unit Electrical and Physical Data table for additional details

Indoor and Outdoor Coils

  • Copper tube with aluminum fin coils

High Pressure Switch

  • Shuts off unit if abnormal operating conditions cause the refrigerant discharge pressure to rise above acceptable levels

Low Pressure Switch

  • Provides loss of charge protection by shutting off unit if refrigerant liquid pressure falls below acceptable levels

Reversing Valve

  • Reverses the direction of refrigerant flow within the unit’s refrigeration circuit, to change between cooling and heating operation
  • Reverses refrigerant flow direction during heat pump defrost cycles to clear outdoor coil of frost buildup

Defrost Control

  • Factory mounted sensor determines when defrost cycle starts and ends
  • Anti-short cycle, timed-off control (field-adjustable to 30-90 minutes) is incorporated in the control board
  • The time between defrost cycles is preset at 90- minute intervals at the factory, but can be field adjusted to 30 or 60 minutes

Low Ambient Operation

  • Units are not equipped with low ambient compressor cutoffs and can be safely operated to -5°F outdoor ambient temperatures
  • Refer to Extended Heating Performance Data tables for performance data starting at 0°F outdoor ambient temperature

TRANSFORMER 

  • Rated for 40VA
  • Factory wired for 230/240V power supply, and includes field selectable terminal for 208V
  • Converts line voltage to 24V for the thermostat and control circuits within the unit

SUPPLY AIR BLOWER Constant Torque ECM Blower Motor

  • Motor provides specified air volume at 0.1 in. – 0.5 in. w.c. external static pressure
  • Blower assembly is easily removed for servicing
  • Refer to Blower Performance tables for additional details

Electronic Blower Control

  • Dedicated blower speed taps for continuous fan, cooling, and heating operation are programmed for optimal airflow and controlled by 24V thermostat signals
  • Blower speed adjustment is easily accomplished by speed tap selection
  • Fixed blower delays have been selected to enhance comfort
  • Refer to Blower Performance tables for additional details

OUTDOOR FAN

  • Heavy-duty, fully enclosed, and weatherproof
  • Aluminum fan blades

CONDENSATE MANAGEMENT Primary Drain Pan

  • Antimicrobial protection: drain pan is injected with an antibacterial agent that destabilizes the membrane of microorganism cells, disrupting the cellular function of odor-causing mold and bacteria so that they can no longer grow or reproduce

Overflow Protection

  • The indoor drain pan overflow switch monitors the condensate level in the primary drain pan
  • Prevents unit from running if water is sensed

Secondary Drain Pan

  • The polypropylene wall sleeve base is specifically designed to direct rainwater out of the building and in the event of any restriction in the primary drain will act as a redundant overflow protection

OPTIONS & ACCESSORIES

FACTORY-INSTALLED OPTIONS ELECTRIC HEAT

  • Mounted internal to unit cabinet
  • Multiple kW sizes available; must specify the electric heating element size (3kW to 10kW)
  • Optional two-stage electric heat wiring on 7 & 10kW. In order to utilize this option, it will require a thermostat with single stage cooling and two stage heating
  • Compatible with 208V, 230V and 240V
  • Helix wound nichrome heating elements exposed directly into the air stream resulting in instant heat transfer and low element temperatures
  • Cutoff limit control provides positive protection in case of excessive temperatures
  • Refer to the Rated Cooling & Heating Performance table for additional details

CORROSION PROTECTION

  • Epoxy-coated indoor and outdoor coils

FIELD-INSTALLED ACCESSORIES

WALL SLEEVES & LOUVERS

  • Units must be installed with approved wall sleeve and louver accessories for safe operation and are required for all installations
  • Larger height wall sleeves may be used on smaller tonnage equipment to maintain a uniform wall opening on the building façade
  • Refer to Wall Sleeves and Louvers table for additional details

WALL SLEEVES (SLEEVE)

  • Penetrates the building envelope and creates a path for condenser air intake and exhaust
  • Provides a sealed connection to the unit and a secure attachment foundation for the louvers
  • Available in 6 in. to 12 in. depths

WALL SLEEVE EXTENSION (ASLEEVEXT4)

  • Provides an additional 4 in. of depth to the wall sleeve, for a maximum depth of 16 in.

LOUVERS Polypropylene Louvers (ALVRP)

  • Constructed from durable, corrosion-resistant plastic
  • Available in four standard colors

Aluminum Louvers (ALVRAL)

  • Constructed with 6063-T6 grade aluminum
  • Available in the anodized clear coat, primer (to be painted in the field), standard paint colors, and custom colors with paint matching*

Impact-Resistant Aluminum Louvers (ALVRALC)

  • Impact and wind load certified up to 186 MPH, risk categories III and IV, and wind exposures C and D
  • ALVRALC-1 & ALVRALC-2: FBC Notice of Acceptance (NOA) 18-0522.03
  • ALVRALC-3 & ALVRALC-4: FBC Notice of Acceptance (NOA) 20-0612.02
  • Constructed with 6063-T6 grade aluminum
  • Available in the anodized clear coat, primer (to be painted in the field), standard paint colors, and custom colors with paint matching*

CRANKCASE HEATER (ACASE841)

  • Warms compressor crankcase to limit migration of liquid refrigerant back to the compressor during the off cycle
  • Available for models with scroll compressors
  • Refer to the Crankcase Heater table for additional details

SHORT CIRCUIT CURRENT RATING KIT (ASCCR)

  • Provides 200kA of SCCR protection
  • Refer to the SCCR Accessory table for additional details

FILTERS

  • Field-supplied filters up to MERV 6 can typically be installed in the filter slot internal to the unit

NOTE: Use of paper frame not recommended

VENTILATION DAMPERS

  • Check that the equipment complies with all applicable building codes, laws, and regulations for its intended use prior to installation Motorized Damper w/ Controller (AVADAMP1)
  • Utilizes a ventilation air control module that is field programmable to assist with meeting ASHRAE 62.2 requirements
  • Once programmed with values for ventilation air amounts, the control module opens the damper in response to thermostat inputs and monitors the run time
  • Upon meeting the ventilation air needs, the control module will close the damper until the start of the next cycle
  • If, during an observation period it is determined that thermostat operation alone may not provide the desired ventilation air, the control module can independently operate the unit’s indoor blower, in continuous fan mode, and open the damper to aid in providing ventilation air needs

Motorized Damper w/ Field-Supplied Relay (AVADAMP2)

  • Opens ventilation air damper during indoor blower operation and closes during blower off periods
  • Requires field-supplied and installed current sensing relay to detect indoor blower operation

THERMOSTAT

  • Required for all installations (field-supplied)
  • Units are individually controlled with conventional 24V thermostat
  • Thermostat must be capable of:
  • Single stage cooling, single stage heat pump operation (compressor heating), and single stage electric heat (3 and 5 kW)
  • Single stage cooling, single stage heat pump operation (compressor heating), and two stage electric heat (7 and 10 kW)
  • Refer to Unit Electrical and Physical Data table for additional details

UNIT ELECTRICAL AND PHYSICAL DATA (208/230 Volt – 1 Phase – 60HZ)1

 

 

 

 

Model

 

MCA2

 

MOCP3.

Default SCCR (kA)4  

Compressor

 

Outdoor Fan

 

Indoor Blower

R-410A Refrigerant Charge (oz) Approx. Shipping Weight (lbs)
Circuit 15 Circuit 25 Circuit 15 Circuit 25 Rated Load Amps (RLA) Locked Rotor Amps (LRA) Dia. (in)  

Nominal RPM

Rated Load Amps (RLA) Rated HP Wheel D x W (in.) Rated Load Amps (RLA) Rated HP
 

208V

 

230V

 

208V

 

230V

 

208V

 

230V

 

208V

 

230V

3MHP4-12-091*P 23.0 25.5 25 30  

5

 

4.4

 

21

 

16

 

1100

 

0.9

 

1/8

 

9 x 6

 

0.4

 

1/3

 

44

 

192

5MHP4-12-091*P 28.4 31.8 30 35
3MHP4-12-121*P 24.2 26.7 25 30  

5

 

5.1

 

27

 

16

 

1125

 

0.9

 

1/8

 

9 x 6

 

0.6

 

1/3

 

44

 

202

5MHP4-12-121*P 29.6 32.9 30 35
3MHP4-12-181*P 26.6 29.1 30 30  

 

 

5

 

 

 

6.7

 

 

 

37.5

 

 

 

16

 

 

 

1125

 

 

 

0.9

 

 

 

1/8

 

 

 

9 x 6

 

 

 

1

 

 

 

1/3

 

 

 

70

 

 

 

219

5MHP4-12-181*P 32.0 35.3 35 40
7MHP4-12-181*P 42.8 47.8 45 50
10MHP4-12-181*P 10.3 10.3 43.3 50.0 15 15 45 50
5MHP4-12-241*P 37.4 40.8 40 45  

 

5

 

 

10

 

 

52

 

 

18

 

 

1100

 

 

1.6

 

 

1/4

 

 

9 x 6

 

 

1.6

 

 

1/3

 

 

83

 

 

268

7MHP4-12-241*P 48.3 53.3 50 60
10MHP4-12-241*P 15.8 15.8 43.3 50.0 25 25 45 50
5MHP4-12-301*P 41.9 45.2 50 50  

 

5

 

 

13.4

 

 

72.5

 

 

18

 

 

1100

 

 

1.6

 

 

1/4

 

 

10 x 8

 

 

1.8

 

 

1/2

 

 

78

 

 

271

7MHP4-12-301*P 20.2 20.2 32.5 37.5 30 30 35 40
10MHP4-12-301*P 20.2 20.2 43.3 50.0 30 30 45 50
5MHP4-14-361*P 45.6 48.9 50 50  

 

5

 

 

14.7

 

 

75

 

 

18

 

 

1100

 

 

2.8

 

 

1/3

 

 

10 x 8

 

 

2.8

 

 

1/2

 

 

90

 

 

299

7MHP4-14-361*P 23.9 23.9 32.5 37.5 35 35 35 40
10MHP4-14-361*P 23.9 23.9 43.3 50.0 35 35 45 50
  1. Acceptable voltage range 197 – 253V
  2. MCA = Minimum Circuit Ampacity
  3. MOCP = Maximum Over Current Protection
  4. SCCR = Short Circuit Current Rating; refer to SCCR Accessory table, up to 200kA
  5. Circuits 1 and 2 are independent sets of power wires being run to the unit, each backed by an independent circuit breaker. Units with dual circuits use Circuit 2 exclusively to power electric heaters. Refer to the wiring diagram for additional details.
    • NOTE: Units are rated at 208/230V, but MOCP & MCA values are calculated at 240V
    • NOTE: The 7.2 and 10 kW heats strips offer a W1 and W2 thermostat connection. Taking advantage of the two heat strip circuits requires a 3-stage thermostat (Y for heat pump, W1 for electric heat stage 1, and W2 for electric heat stage 2). If a 2-stage thermostat is used, “pigtail” W1 and W2 wires together when connecting the thermostat wires at the unit.

UNIT DIMENSIONS (IN.)

Model A B* C D E F G H J K L M N
*MHP4-12-091*P

*MHP4-12-121*P

43-7/8 16-7/8 25-1/4 21-1/2 18-5/8 19-1/4 6 8 16 17-1/16 3/4 2-1/4 24-5/8
*MHP4-12-181*P 47-7/8 18-7/8 27-1/4 21-1/2 20-5/8 21-1/4 6 8 16 17-1/16 3/4 2-1/4 26-5/8
*MHP4-12-241*P 55-7/8 22-7/8 31-1/4 24-3/8 24-5/8 25-1/4 6 8 16 22-7/16 3/4 1 30-5/8
*MHP4-12-301*P 55-7/8 22-7/8 31-1/4 24-3/8 24-5/8 25-1/4 6 11-3/8 10-7/16 22-7/16 3-3/4 1 30-5/8
*MHP4-14-361*P 67-7/8 26-7/8 35-1/4 24-3/8 28-5/8 29-1/4 10 11-3/8 10-7/16 22-7/16 3-3/4 1 38-5/8
  • Dimension B represents the height of the optional front return air duct openingmagic-pak-5MHP4-12-241FP-Electric-Heat-Packaged-Unit-FIG-2
  • Provisions must be made to properly drain condensate from the primary and secondary drain pans.

MINIMUM CLEARANCES

Accessibility Clearances
The front of the unit must be accessible for service. A minimum clearance of 30” in front of unit is required for service. If the unit is enclosed, a door or access panel aligned with the front of the unit is the preferred method of providing access. The door or access panel opening must be a minimum of 30” wide (centered on the unit) and be as tall as the unit.

IMPORTANT
The unit must be installed with approved wall sleeve and louver accessories for safe operation. Improper installations could result in property damage, personal injury, or death.

Supply Duct Clearances

Minimum Clearances to Combustible Materials1
Front Sides Top
0” 0” 0”
  • Accessibility clearances take precedence
Unit Clearances Minimum Clearances1
Return Duct Configuration Unit Height Front Sides3
Ducted Top Opening All See Note 2 1”
Ducted Front Opening5 All See Note 2 & 4 1”
Non-Ducted/ Free Return 43” 4” 1”
48” – 68” 5” 1”
  1. Accessibility clearances take precedence
  2. Clearance must accommodate field-installed condensate drain line / drain trap
  3. Additional clearance is required if the field-installed condensate drain line/drain trap is routed alongside unit
  4. Consult local codes for other clearance requirements
  5. If ductwork is attached to the optional front return opening, provisions to the service unit filter must be provided

Top View

magic-pak-5MHP4-12-241FP-Electric-Heat-Packaged-Unit-FIG-3

Side View

magic-pak-5MHP4-12-241FP-Electric-Heat-Packaged-Unit-FIG-4

OUTDOOR SOUND RATING & CABINET AIR LEAKAGE

Model Outdoor Sound Rating (dBa)1 Cabinet Air Leakage (%)2
*MHP4-12-091*P 73 1.4
*MHP4-12-121*P 73 1.4
*MHP4-12-181*P 73 1.4
*MHP4-12-241*P 79 1.4
*MHP4-12-301*P 79 1.4
*MHP4-14-361*P 79 1.4
  1. Per ANSI / AHRI Standard 270
  2. Per ASHRAE Standard 193

FACTORY FILTER SIZE (IN.) AND PRESSURE DROP (IN. W.C.)

 

Model

 

Filter Size

Supply Airflow (CFM)
200 300 400 500 600 700 800 900 1000 1100 1200 1300
*MHP4-12-091*P

*MHP4-12-121*P

18 x 20 x 1 0.01 0.01 0.01 0.02 0.03 0.04
*MHP4-12-181*P 20 x 20 x 1 0.01 0.01 0.02 0.02 0.03 0.04
*MHP4-12-241*P

*MHP4-12-301*P

24 x 22 x 1 0.01 0.01 0.02 0.03 0.03 0.04 0.05
*MHP4-14-361*P 28 x 22 x 1 0.01 0.01 0.02 0.02 0.03 0.03 0.04 0.04
  • Performance-based on factory-provided washable filter installed in the unit. If a higher resistance filter is field installed in the unit, the added resistance must be included in the external static pressure and must not exceed 0.5 in. w.c. including ductwork.

VENTILATION AIR CAPABILITY

The chart and figure below show the amount of ventilation air as a function of unit tonnage and total External Static Pressure (supply and return).

  Ventilation Air (CFM) *
Cumulative Knockouts Removed Total External Static Pressure (supply + return) **
0.1 0.2 0.3 0.4 0.5
0.75, 1.0, 1.5 TON # 1 Only 7 9 12 15 18
#1 thru #2 10 15 20 24 28
#1 thru #3 12 18 25 32 38
#1 thru #4 18 28 36 45 54
#1 thru #5 23 35 46 57 69
#1 thru #6 27 41 54 67 80
#1 thru #7 32 48 63 78 93
#1 thru #8 37 55 73 90 107
#1 thru #9 41 61 80 100 118
2.0, 2.5, 3.0 TON # 1 Only 21 20 19 17 16
#1 thru #2 28 27 25 24 22
#1 thru #3 35 33 32 30 28
#1 thru #4 45 42 40 38 35
#1 thru #5 55 52 49 46 43
#1 thru #6 66 62 59 55 52
#1 thru #7 79 75 71 66 62
#1 thru #8 91 86 81 76 71
#1 thru #9 105 99 94 88 82
  • Assumes proper speed tap adjustments to maintain nominal supply air CFM
  • Assumes equal supply and return static pressuresmagic-pak-5MHP4-12-241FP-Electric-Heat-Packaged-Unit-FIG-5

WALL SLEEVES & LOUVERS

 

Wall Sleeves

 

Louvers

 

Model

Dimensions (in.)
Wall Sleeve Wall Opening
 

 

 

Wall Sleeve

 

 

Wall Sleeve Extension

 

 

Polypropylene Louvers

 

 

Aluminum Louvers

 

 

Impact Louvers

*MHP4-12-091*P *MHP4-12-121*P *MHP4-12-181*P *MHP4-12-241*P *MHP4-12-301*P *MHP4-14-361*P  

 

Height (A)

 

 

Height (B)

Depth (C)
 

Sleeve Only

Sleeve Plus Extension
ASLEEVE6-1 ALVRP***-1 ALVRAL-1^ ALVRALC-1^       29 29-1/8 6
ASLEEVE8-1 ALVRP***-1 ALVRAL-1^ ALVRALC-1^       29 29-1/8 8
ASLEEVE10-1 ASLEEVEXT4-1 ALVRP***-1 ALVRAL-1^ ALVRALC-1^       29 29-1/8 10 14
ASLEEVE12-1 ASLEEVEXT4-1 ALVRP***-1 ALVRAL-1^ ALVRALC-1^       29 29-1/8 12 16
ASLEEVE6-2 ALVRP***-2 ALVRAL-2^ ALVRALC-2^         32-3/4 32-7/8 6
ASLEEVE8-2 ALVRP***-2 ALVRAL-2^ ALVRALC-2^         32-3/4 32-7/8 8
ASLEEVE10-2 ASLEEVEXT4-2 ALVRP***-2 ALVRAL-2^ ALVRALC-2^         32-3/4 32-7/8 10 14
ASLEEVE12-2 ASLEEVEXT4-2 ALVRP***-2 ALVRAL-2^ ALVRALC-2^         32-3/4 32-7/8 12 16
ASLEEVE6-2 ALVRP***-2 ALVRAL-7^         32-3/4 32-7/8 6
ASLEEVE8-2 ALVRP***-2 ALVRAL-7^         32-3/4 32-7/8 8
ASLEEVE10-2 ASLEEVEXT4-2 ALVRP***-2 ALVRAL-7^         32-3/4 32-7/8 10 14
ASLEEVE12-2 ASLEEVEXT4-2 ALVRP***-2 ALVRAL-7^         32-3/4 32-7/8 12 16
ASLEEVE6-5 ALVRP***-3 45 45-1/8 6
ASLEEVE8-5 ALVRP***-3 45 45-1/8 8
ASLEEVE10-5 ASLEEVEXT4-3 ALVRP***-3 45 45-1/8 10 14
ASLEEVE12-5 ASLEEVEXT4-3 ALVRP***-3 45 45-1/8 12 16
ASLEEVE6-5 ALVRAL-3^ ALVRALC-3^       45 45-1/8 6
ASLEEVE8-5 ALVRAL-3^ ALVRALC-3^       45 45-1/8 8
ASLEEVE10-5 ASLEEVEXT4-3 ALVRAL-3^ ALVRALC-3^       45 45-1/8 10 14
ASLEEVE12-5 ASLEEVEXT4-3 ALVRAL-3^ ALVRALC-3^       45 45-1/8 12 16
ASLEEVE6-5 ALVRAL-4^ ALVRALC-4^       45 45-1/8 6
ASLEEVE8-5 ALVRAL-4^ ALVRALC-4^       45 45-1/8 8
ASLEEVE10-5 ASLEEVEXT4-3 ALVRAL-4^ ALVRALC-4^       45 45-1/8 10 14
ASLEEVE12-5 ASLEEVEXT4-3 ALVRAL-4^ ALVRALC-4^       45 45-1/8 12 16

Note: Wall Sleeve and Louver size must be coordinated

  • Louver colors: WHT = white, SAN = sandstone, BGE = beige, TPST = taupestone
  • P: Option to paint standard, aluminum, and impact-resistant louver
  • Wall sleeve and louver sizes equal to the required wall opening dimensions for the unit size
    • Optional: Wall sleeves and louvers can be oversized to maintain a uniform appearance

WALL SLEEVE & WALL OPENING DIMENSIONS (IN.)

magic-pak-5MHP4-12-241FP-Electric-Heat-Packaged-Unit-FIG-6

SCCR ACCESSORY

Model Kit1
3MHP4-12-091 ASCCR2
5MHP4-12-091 ASCCR3
3MHP4-12-121 ASCCR2
5MHP4-12-121 ASCCR3
3MHP4-12-181 ASCCR2
5MHP4-12-181 ASCCR3
7MHP4-12-181 ASCCR4
10MHP4-12-181 ASCCR6
5MHP4-12-241 ASCCR4
7MHP4-12-241 ASCCR5
10MHP4-12-241 ASCCR7
5MHP4-12-301 ASCCR4
7MHP4-12-301 ASCCR8
10MHP4-12-301 ASCCR7
5MHP4-14-361 ASCCR4
7MHP4-14-361 ASCCR9
10MHP4-14-361 ASCCR10

CRANKCASE HEATER

Model Kit
*MHP4-12-091*P  

 

N/A

*MHP4-12-121*P
*MHP4-12-181*P
*MHP4-12-241*P  

 

ACASE841

*MHP4-12-301*P
*MHP4-14-361*P

RATED COOLING & HEATING PERFORMANCE

 

 

 

Model

 

 

Supply Airflow (SCFM)

Cooling Heating Electric Heat
 

Net Capacity (Btu/hr)

 

Efficiency (SEER)

 

Efficiency (EER)

 

 

S/T^

47°F 240V 230V 208V
Net Capacity (Btu/hr) Efficiency (HSPF)  

kW

 

BTU/hr

 

kW

 

BTU/hr

 

kW

 

BTU/hr

3MHP4-12-091*P  

350

 

8,600

 

12.0

 

11.0

 

0.79

 

8,600

 

7.4

3.60 12,284 3.31 11,281 2.70 9,226
5MHP4-12-091*P 4.80 16,378 4.41 15,042 3.61 12,302
3MHP4-12-121*P  

475

 

12,000

 

12.5

 

11.0

 

0.79

 

11,400

 

7.4

3.60 12,284 3.31 11,281 2.70 9,226
5MHP4-12-121*P 4.80 16,378 4.41 15,042 3.61 12,302
3MHP4-12-181*P  

 

 

 

600

 

 

 

 

16,500

 

 

 

 

12.0

 

 

 

 

11.0

 

 

 

 

0.77

 

 

 

 

16,200

 

 

 

 

7.4

3.60 12,284 3.31 11,281 2.70 9,226
5MHP4-12-181*P 4.80 16,378 4.41 15,042 3.61 12,302
7MHP4-12-181*P 7.20 24,567 6.61 22,563 5.41 18,453
10MHP4-12-181*P 9.60 32,757 8.82 30,084 7.21 24,604
5MHP4-12-241*P  

 

800

 

 

22,800

 

 

13.0

 

 

11.0

 

 

0.76

 

 

22,800

 

 

7.4

4.80 16,378 4.41 15,042 3.61 12,302
7MHP4-12-241*P 7.20 24,567 6.61 22,563 5.41 18,453
10MHP4-12-241*P 9.60 32,757 8.82 30,084 7.21 24,604
5MHP4-12-301*P  

 

1,025

 

 

27,600

 

 

12.5

 

 

11.0

 

 

0.75

 

 

26,200

 

 

7.4

4.80 16,378 4.41 15,042 3.61 12,302
7MHP4-12-301*P 7.20 24,567 6.61 22,563 5.41 18,453
10MHP4-12-301*P 9.60 32,757 8.82 30,084 7.21 24,604
5MHP4-14-361*P  

 

1,200

 

 

34,600

 

 

14.0

 

 

11.0

 

 

0.75

 

 

32,400

 

 

8.0

4.80 16,378 4.41 15,042 3.61 12,302
7MHP4-14-361*P 7.20 24,567 6.61 22,563 5.41 18,453
10MHP4-14-361*P 9.60 32,757 8.82 30,084 7.21 24,604
  • ^ Not a rated value
  • † Two-stage heat available for 7kW and 10kW units
  • S/T = ratio of sensible to total cooling load
  • SCFM = standard cubic feet per minute

EXTENDED HEATING PERFORMANCE DATA (HEAT PUMP ONLY)

 

 

 

Model

Outdoor Temperature – DB / WB (°F)
0 / 0 17 / 15 35 / 33 47 / 43 62 / 56
 

Net Capacity (Btu/hr)

System Power Input (kW)  

Net Capacity (Btu/hr)

System Power Input (kW)  

Net Capacity (Btu/hr)

System Power Input (kW)  

Net Capacity (Btu/hr)

System Power Input (kW)  

Net Capacity (Btu/hr)

System Power Input (kW)
*MHP4-12-091*P 3,600 0.68 5,200 0.71 7,200 0.74 8,600 0.76 10,300 0.79
*MHP4-12-121*P 6,200 0.98 6,800 0.93 9,500 0.98 11,400 1.01 13,800 1.05
*MHP4-12-181*P 7,100 1.19 9,200 1.28 13,500 1.38 16,200 1.44 19,600 1.52
*MHP4-12-241*P 9,800 1.91 14,000 1.95 19,300 2.00 22,800 2.02 27,100 2.06
*MHP4-12-301*P 11,700 2.02 16,400 2.18 22,100 2.27 26,200 2.33 31,300 2.40
*MHP4-14-361*P 16,700 2.40 20,400 2.69 27,600 2.80 32,400 2.88 38,400 2.97

COMBINED EXTENDED HEATING PERFORMANCE DATA (HEAT PUMP + ELECTRIC HEAT) 1

 

Tonnage

 

 

 

 

Model

Outdoor Temperature – DB / WB (°F)
17 / 15 35 / 33
208V 230V 208V 230V
Combined Heating Capacity (Btu/hr) Combined System Power Input (kW) Combined Heating Capacity (Btu/hr) Combined System Power Input (kW) Combined Heating Capacity (Btu/hr) Combined System Power Input (kW) Combined Heating Capacity (Btu/hr) Combined System Power Input (kW)
 

0.75

3MHP4-12-091*P 14,300 3.41 16,400 4.02 16,300 3.44 18,400 4.05
5MHP4-12-091*P 17,400 4.32 20,200 5.12 19,400 4.35 22,200 5.15
 

1.0

3MHP4-12-121*P 15,900 3.63 18,000 4.24 18,600 3.68 20,700 4.29
5MHP4-12-121*P 19,000 4.54 21,800 5.34 21,700 4.59 24,500 5.39
 

1.5

3MHP4-12-181*P 18,300 3.98 20,400 4.59 22,500 4.08 24,700 4.69
5MHP4-12-181*P 21,400 4.89 24,200 5.69 25,600 4.99 28,500 5.79
7MHP4-12-181*P 27,500 6.69 31,700 7.89 31,800 6.79 36,000 7.99
10MHP4-12-181*P 33,700 8.49 39,200 10.10 37,900 8.59 43,500 10.20
 

2.0

5MHP4-12-241*P 26,100 5.56 29,000 6.36 31,400 5.61 34,300 6.41
7MHP4-12-241*P 32,300 7.36 36,500 8.56 37,500 7.41 41,800 8.61
10MHP4-12-241*P 38,400 9.16 44,000 10.77 43,700 9.21 49,300 10.82
 

2.5

5MHP4-12-301*P 28,500 5.79 31,400 6.59 34,100 5.88 37,100 6.68
7MHP4-12-301*P 34,600 7.59 38,900 8.79 40,300 7.68 44,600 8.88
10MHP4-12-301*P 40,800 9.39 46,400 11.00 46,400 9.48 52,100 11.09
 

3.0

5MHP4-14-361*P 32,400 6.30 35,400 7.10 39,600 6.41 42,600 7.21
7MHP4-14-361*P 38,600 8.10 42,900 9.30 45,700 8.21 50,100 9.41
10MHP4-14-361*P 44,700 9.90 50,400 11.51 51,900 10.01 57,600 11.62
  1. The combined performance of Heat Pump operation (compressor) plus Electric Heat (including second-stage electric heat on 7.5 & 10kW).
  2. The combined performance of Heat Pump operation (compressor) plus Electric Heat (including second-stage electric heat on 7.5 & 10kW).
 

Tonnage

 

 

 

Model

Outdoor Temperature – DB / WB (°F)
47 / 43 62 / 56
208V 230V 208V 230V
Combined Heating Capacity (Btu/hr) Combined System Power Input (kW) Combined Heating Capacity (Btu/hr) Combined System Power Input (kW) Combined Heating Capacity (Btu/hr) Combined System Power Input (kW) Combined Heating Capacity (Btu/hr) Combined System Power Input (kW)
 

0.75

3MHP4-12-091*P 17,700 3.46 19,800 4.07 19,400 3.49 21,500 4.10
5MHP4-12-091*P 20,800 4.37 23,600 5.17 22,400 4.40 25,300 5.20
 

1.0

3MHP4-12-121*P 20,500 3.71 22,600 4.32 22,800 3.75 25,000 4.36
5MHP4-12-121*P 23,500 4.62 26,400 5.42 25,900 4.66 28,800 5.46
 

1.5

3MHP4-12-181*P 25,200 4.14 27,400 4.75 28,600 4.22 30,800 4.83
5MHP4-12-181*P 28,300 5.05 31,200 5.85 31,700 5.13 34,600 5.93
7MHP4-12-181*P 34,400 6.85 38,700 8.05 37,800 6.93 42,100 8.13
10MHP4-12-181*P 40,600 8.65 46,200 10.26 44,000 8.73 49,600 10.34
 

2.0

5MHP4-12-241*P 34,800 5.63 37,800 6.43 39,100 5.67 42,100 6.47
7MHP4-12-241*P 41,000 7.43 45,300 8.63 45,200 7.47 49,600 8.67
10MHP4-12-241*P 47,100 9.23 52,800 10.84 51,400 9.27 57,100 10.88
 

2.5

5MHP4-12-301*P 38,200 5.94 41,200 6.74 43,200 6.01 46,300 6.81
7MHP4-12-301*P 44,300 7.74 48,700 8.94 49,400 7.81 53,800 9.01
10MHP4-12-301*P 50,500 9.54 56,200 11.15 55,500 9.61 61,300 11.22
 

3.0

5MHP4-14-361*P 44,300 6.49 47,400 7.29 50,300 6.58 53,400 7.38
7MHP4-14-361*P 50,500 8.29 54,900 9.49 56,400 8.38 60,900 9.58
10MHP4-14-361*P 56,600 10.09 62,400 11.70 62,600 10.18 68,400 11.79

EXTENDED COOLING PERFORMANCE DATA

Tonnage Model  

 

Indoor Temp DB/WB (°F)

Outdoor Temperature – DB (°F)
65 85 95 105 115
 

Net Capacity (Btu/hr)

 

S/T

System Power Input (kW)  

Net Capacity (Btu/hr)

 

S/T

System Power Input (kW)  

Net Capacity (Btu/hr)

 

S/T

System Power Input (kW)  

Net Capacity (Btu/hr)

 

S/T

System Power Input (kW)  

Net Capacity (Btu/hr)

 

S/T

System Power Input (kW)
0.75 *MHP4-12-091*P 85/72 10,800 0.64 0.62 9,900 0.68 0.72 9,400 0.70 0.77 8,700 0.74 0.85 8,000 0.77 0.94
80/67 10,200 0.70 0.61 9,100 0.76 0.72 8,600 0.79 0.77 7,900 0.82 0.84 7,200 0.85 0.91
75/63 9,500 0.74 0.61 8,400 0.79 0.72 7,900 0.82 0.77 7,100 0.86 0.83 6,400 0.90 0.89
75/57 8,800 1.00 0.61 7,700 1.00 0.71 7,200 1.00 0.76 6,700 1.00 0.83 6,100 1.00 0.89
1.0 *MHP4-12-121*P 85/72 15,100 0.64 0.82 13,700 0.67 1.01 13,000 0.69 1.10 12,000 0.73 1.21 11,000 0.76 1.32
80/67 14,100 0.72 0.82 12,700 0.77 1.00 12,000 0.79 1.09 11,000 0.83 1.19 9,900 0.86 1.29
75/63 13,300 0.74 0.82 11,800 0.79 0.99 11,000 0.81 1.07 9,900 0.86 1.17 8,800 0.90 1.27
75/57 12,100 1.00 0.81 10,800 1.00 0.98 10,200 1.00 1.06 9,300 1.00 1.16 8,500 1.00 1.26
1.5 *MHP4-12-181*P 85/72 21,200 0.60 1.14 19,300 0.65 1.38 18,400 0.67 1.50 16,900 0.72 1.64 15,400 0.77 1.78
80/67 19,900 0.67 1.13 18,000 0.74 1.38 17,000 0.77 1.50 15,300 0.82 1.63 13,600 0.86 1.77
75/63 18,800 0.72 1.13 16,800 0.77 1.36 15,800 0.80 1.48 14,000 0.85 1.61 12,200 0.90 1.74
75/57 17,100 1.00 1.13 15,300 1.00 1.36 14,400 1.00 1.47 13,300 1.00 1.60 12,100 1.00 1.74
2.0 *MHP4-12-241*P 85/72 27,900 0.60 1.54 25,800 0.65 1.89 24,700 0.67 2.06 23,000 0.70 2.28 21,400 0.73 2.50
80/67 26,200 0.67 1.55 23,900 0.73 1.90 22,800 0.76 2.07 20,900 0.80 2.29 19,000 0.84 2.50
75/63 24,800 0.71 1.55 22,400 0.76 1.88 21,200 0.79 2.05 19,100 0.84 2.26 17,100 0.88 2.48
75/57 22,700 1.00 1.55 20,300 1.00 1.88 19,200 1.00 2.04 17,700 1.00 2.26 16,200 1.00 2.49
2.5 *MHP4-12-301*P 85/72 33,000 0.64 1.92 31,700 0.66 2.37 31,100 0.67 2.59 29,200 0.69 2.90 27,300 0.71 3.20
80/67 32,000 0.70 1.91 29,500 0.73 2.35 28,200 0.75 2.56 26,600 0.78 2.85 25,100 0.80 3.13
75/63 31,100 0.72 1.90 28,800 0.76 2.33 27,700 0.78 2.54 25,400 0.81 2.83 23,200 0.84 3.11
75/57 27,900 1.00 1.87 26,600 1.00 2.30 25,900 1.00 2.51 24,000 1.00 2.80 22,100 1.00 3.10
3.0 *MHP4-14-361*P 85/72 41,300 0.63 2.27 38,400 0.66 2.80 36,900 0.67 3.06 34,500 0.70 3.37 32,200 0.72 3.68
80/67 39,200 0.69 2.25 36,100 0.73 2.77 34,600 0.75 3.04 32,000 0.78 3.34 29,500 0.81 3.64
75/63 37,300 0.72 2.25 33,800 0.76 2.75 32,100 0.78 2.99 29,500 0.81 3.29 27,000 0.84 3.59
75/57 33,900 1.00 2.25 31,100 1.00 2.73 29,700 1.00 2.97 27,600 1.00 3.27 25,500 1.00 3.58

BLOWER PERFORMANCE

  • Performance-based on factory-provided washable filter installed in the unit.
  • If a higher resistance filter is field installed in the unit, the added resistance must be included in the external static pressure and must not exceed 0.5 in. w.c. including ductwork
  • Refer to Factory Filter Size and Pressure Drop table for additional details
SUPPLY AIRFLOW PERFORMANCE AS A FUNCTION OF EXTERNAL STATIC PRESSURE
Tonnage Model  

Indoor Blower Speed

0.1″ w.c. 0.2″ w.c. 0.3″ w.c. 0.4 “w.c. 0.5″ w.c.
SCFM Watts HP SCFM Watts HP SCFM Watts HP SCFM Watts HP SCFM Watts HP
0.75 *MHP4-12-091*P TAP 1 (FAN) 365 28 0.04 330 31 0.04 275 35 0.05 225 38 0.05 180 41 0.05
TAP 2 (COOL / HP)† 375 28 0.04 325 32 0.04 275 35 0.05 N/A N/A N/A N/A N/A N/A
TAP 3 (COOL / HP) N/A N/A N/A N/A N/A N/A 395 54 0.07 370 58 0.08 330 62 0.08
3 kW TAP 4 (HEAT)* 515 55 0.07 485 58 0.08 450 62 0.08 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) 600 73 0.10 570 78 0.10 545 84 0.11 515 88 0.12 475 92 0.12
5 kW TAP 4 (HEAT)* 570 69 0.09 545 73 0.10 515 77 0.10 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) 660 92 0.12 635 98 0.13 605 104 0.14 580 109 0.15 550 114 0.15
1.0 *MHP4-12-121*P TAP 1 (FAN) 365 28 0.04 330 31 0.04 275 35 0.05 225 38 0.05 180 41 0.05
TAP 2 (COOL / HP)† 490 50 0.07 460 55 0.07 420 59 0.08 N/A N/A N/A N/A N/A N/A
TAP 3 (COOL / HP) N/A N/A N/A 555 77 0.10 525 82 0.11 495 86 0.12 460 91 0.12
3 kW TAP 4 (HEAT)* 515 55 0.07 485 58 0.08 450 62 0.08 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) 600 73 0.10 570 78 0.10 545 84 0.11 515 88 0.12 475 92 0.12
5 kW TAP 4 (HEAT)* 570 69 0.09 545 73 0.10 515 77 0.10 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) 660 92 0.12 635 98 0.13 605 104 0.14 580 109 0.15 550 114 0.15
1.5 *MHP4-12-181*P TAP 1 (FAN) 365 32 0.04 335 35 0.05 280 39 0.05 235 42 0.06 175 46 0.06
TAP 2 (COOL / HP)† 615 103 0.14 590 108 0.14 555 112 0.15 530 117 0.16 500 121 0.16
TAP 3 (COOL / HP) 700 135 0.18 670 141 0.19 640 146 0.20 615 151 0.20 590 157 0.21
3 kW TAP 4 (HEAT)* 615 93 0.12 590 97 0.13 555 101 0.14 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) 715 127 0.17 685 134 0.18 655 140 0.19 630 146 0.20 600 151 0.20
5 kW TAP 4 (HEAT)* 665 110 0.15 635 114 0.15 605 118 0.16 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) 750 148 0.20 725 154 0.21 700 160 0.21 675 166 0.22 650 171 0.23
7 kW TAP 4 (HEAT)* 725 137 0.18 705 144 0.19 675 150 0.20 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A 800 200 0.27 780 205 0.27 755 209 0.28 725 213 0.29
10 kW TAP 4 (HEAT)* 750 148 0.20 725 154 0.21 700 161 0.22 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A N/A N/A N/A 805 224 0.30 780 228 0.31 750 232 0.31
2.0 *MHP4-12-241*P TAP 1 (FAN) 460 43 0.06 420 47 0.06 380 51 0.07 350 54 0.07 290 59 0.08
TAP 2 (COOL / HP)† 815 150 0.20 785 161 0.22 760 165 0.22 740 172 0.23 715 178 0.24
TAP 3 (COOL / HP) 885 201 0.27 860 208 0.28 835 213 0.29 805 217 0.29 785 220 0.30
5 kW TAP 4 (HEAT)* 800 146 0.20 775 152 0.20 750 157 0.21 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) 905 201 0.27 880 207 0.28 855 212 0.28 825 216 0.29 800 219 0.29
7 kW TAP 4 (HEAT)* 855 174 0.23 830 179 0.24 800 183 0.25 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A 930 231 0.31 900 235 0.32 875 239 0.32 850 243 0.33
10 kW TAP 4 (HEAT)* 855 174 0.23 830 179 0.24 800 183 0.25 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A 930 231 0.31 900 235 0.32 875 239 0.32 850 243 0.33

BLOWER PERFORMANCE CONTINUED

  • Performance-based on factory-provided washable filter installed in the unit.
  • If a higher resistance filter is field installed in the unit, the added resistance must be included in the external static pressure and must not exceed 0.5 in. w.c. including ductwork
  • Refer to Factory Filter Size and Pressure Drop table for additional details
SUPPLY AIRFLOW PERFORMANCE AS A FUNCTION OF EXTERNAL STATIC PRESSURE
Tonnage Model  

Indoor Blower Speed

0.1″ w.c. 0.2″ w.c. 0.3″ w.c. 0.4 “w.c. 0.5″ w.c.
SCFM Watts HP SCFM Watts HP SCFM Watts HP SCFM Watts HP SCFM Watts HP
2.5 *MHP4-12-301*P TAP 1 (FAN) 590 43 0.06 535 48 0.06 430 55 0.07 380 60 0.08 315 65 0.09
TAP 2 (COOL / HP)† 1040 161 0.22 1005 169 0.23 970 177 0.24 935 185 0.25 900 193 0.26
TAP 3 (COOL / HP) N/A N/A N/A 1105 211 0.28 1070 220 0.30 1040 229 0.31 1010 237 0.32
5 kW TAP 4 (HEAT)* 1075 151 0.20 1040 159 0.21 1005 168 0.23 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A N/A N/A N/A 1100 205 0.27 1065 216 0.29 1025 225 0.30
7 kW TAP 4 (HEAT)* 1075 151 0.20 1040 159 0.21 1005 168 0.23 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A N/A N/A N/A 1100 205 0.27 1065 216 0.29 1025 225 0.30
10 kW TAP 4 (HEAT)* 1075 151 0.20 1040 159 0.21 1005 168 0.23 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A N/A N/A N/A 1100 205 0.27 1065 216 0.29 1025 225 0.30
3.0 *MHP4-14-361*P TAP 1 (FAN) 680 61 0.08 630 68 0.09 575 74 0.10 525 79 0.11 460 86 0.12
TAP 2 (COOL / HP)† 1235 260 0.35 1200 272 0.36 1165 284 0.38 1135 295 0.40 1100 305 0.41
TAP 3 (COOL / HP) N/A N/A N/A N/A N/A N/A 1250 330 0.44 1215 342 0.46 1180 354 0.47
5 kW TAP 4 (HEAT)* 1240 232 0.31 1205 248 0.33 1170 262 0.35 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A N/A N/A N/A 1260 315 0.42 1230 328 0.44 1200 338 0.45
7 kW TAP 4 (HEAT)* 1240 232 0.31 1205 248 0.33 1170 262 0.35 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A N/A N/A N/A 1260 315 0.42 1230 328 0.44 1200 338 0.45
10 kW TAP 4 (HEAT)* 1240 232 0.31 1205 248 0.33 1170 262 0.35 N/A N/A N/A N/A N/A N/A
TAP 5 (HEAT) N/A N/A N/A N/A N/A N/A 1260 315 0.42 1230 328 0.44 1200 338 0.45

 

  • N/A: Do not operate the unit using this blower speed at this external static pressure.
  • † As shipped speed for Cooling and Heat Pump operation. Blower speed must be field adjusted to Speed Tap 3 for higher duct static applications.
  • As shipped speed for Heating operation. Blower speed must be field adjusted to Speed Tap 5 for higher duct static applications.

All specifications and illustrations are subject to change without notice and without incurring obligations.

215 Metropolitan Drive | West Columbia, SC 29170 800-448-5872 Product Support 866-282-7257 www.magic-pak.com

  • FORM NO. MHP4-100 (09/2022)